0011 lad 115tPlBS Fairbanks Morne Engine Division 701 Lawton Avenus Deteit Wisconsin 53511 21 - O r' I

/

608/364 4411 e

~~

March 22. 1979 Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Ill.

60137 1

Attention: Mr. James G. Keppler, Director, Region III subject: Part 21 Report Colt Industries-Fairbanks Horse Engine Division Emergency Diesel Generators Possible Exhaust Rocker Ann Defect Written Report Dated September 26, 1978 Further Information-Northeast Utilities Millstone Unit 3 Gentlemen:

We have completed our inspection of the exhaust rocker arms of the two PC-2 generator sets for Millstone Unit 3 which have been in storage at our Beloit, Wisconsin plant.

All exhaust rocker ams were removed from the engines and non-destructively examined. Those with stress risers exceeding current criteria were reworked to within acceptance criteria or replaced.

The units are free of the reported potential defect.

Very truly yours, y

MANAGER UTILITY L

JMM:jc cc: Stone & Webster Engineering Corp.

P. O. Box 2325 Boston, Mass. 02107 Attention:

Lead Electrical Engineer J.0. 12179

. 0 'l3I9

/30413OO W A Ovsen W Po Co8t beem f 4**.0r$ Co's