UNITED STATES

- WM j

~

yi

  • t NUCLEAR REGULATORY CO;.1 MISSION 7

'"(

j,

, g WASHING ' ON, D. C. 20555

,8 FEB lh 1979 DOCKET NOS. 50-369 AND 50-370 APPLICANT:

DUKE POWER COMPANY FACILITY:

MCGUIRE NUCLEAR STATION, UNITS 1 & 2 A meeting was held with the applicant on January 18, 1979 in Bethesda, Maryland to discuss an appeal by the applicant of a staff position on the proposed augmented inservice inspection program. presents a list of attendees.

Background

The McGuire FSAR requires the postulation of ruptures in high and moderate energy piping systems.

Determination of break locations are based on the criteria contained therein.

Protection must then be provided for break locations which cause unacceptable damage to essential components due to the effects of pipt.vhip,.iet impingement, compartment pressurization, steam environment, or flooding.

Protection from the effects of pipe whip and jet impingement may require the design and construction of large, high load capacity barriers and restraints. Applicant evaluation has determined that in some instances it is not feasible to install these structures at this stage of plant engineering and construction due to interferences and concrete connection problems.

Applicant Position The apnlicant had proposed the use of augmented inservice inspection, supplemented by local leak detection, to alleviate postulations of ruptures in tne McGuire piping systems.

They had reduced the number of break loca-tions to be included in the program from 22 locations to 6 locations (2 locations on each of three lines). The applicant's position was that acceptable pipe rupture protection meeting the staff intent for such pro-tection can be attained by use of augmented inservice inspection for a very limited number of locations.

bde er 1%odu MN D$u 7 9 0 3 0 7 0 3Cif

. pgp t n7q Staff Position The staff had discussed and considered the applicant's proposal to meet our pipe rupture requirements but had been unable to accept tne proposal.

The staff however had not rejected it outrightly but rather had directed its evaluation toward obtaining acceptable pipe rupture consequences for the remaining limited locations and thus obviate the need for such a program.

The staff position appeared to be rejection of the applicant's proposal.

Summary After extensive discussion by all parties it was agreed that the applicant would provide some additional information which, if totally responsive and satisfactory to the staff would permit the staff to accept an amended ISI program for the limited number of weldments. Enclosure 2 is a letter dated February 9,1979 to the applicant describing the additional informa-tion.

.d'

,hJ L.

Ralph A. Birkel Light Water Reactors Branch No.2 Division of Project Management

Enclosures:

1.

Attendance List 2.

Letter to Duke Power dated February 9,1979 ccs w/ enclosures:

See next pages

Mr. William O. Parker, Jr.

Vice Precident, Steam Production Duke Power Company P. O. Box 2178 422 South Church Street Charlotte, North Carolina 28242 cc:

Mr. W. L. Porter Duke Power Company P. O. Box 2178 422 South Church Street Charlotte, North Carolina 28242 Mr. R. S. Howard Power Systems Division Westinghouse Electric Corporation P. O. Box 355 Pittsburgh, Pennsylvania 15230 Mr. E. J. Keith EDS Nuclear Incorporated 220 Montgomery Street San Francisco, California 94104 Mr. J. E. Houghtaling NUS Corporation 2536 Countryside Boulevard Clearwater, Florida 33515 Mr. Jesse L. Riley, President The Carolina Environmental Study Group 854 Henley Place Charlotte, North Carolina 28207 J. Michael McGarry, III, Esq.

Debevoise & Liberman 700 Shoreham Building 806 15th Street, N. W.

Washington, D. C.

20005 Shelley Blum, Esq.

418 Law Building 730 East Trade Street Charlotte, North Carolina 28202

.g

'/r. William O. Parker, Jr.

cc: Robert M. Lazo, Esq., Chairman Atomic Safety and Licensing Board U. S. fluclear Regulatory Commission Washington, D. C.

20555 Dr. Emmeth A. Luebke Atomic Safety and Licensing Bocrd U. S. fluclear Regulatory Commission Washington, D. C.

20555 Dr. Cadet H. Hand, Jr., Director Bodega Marine Lab of California P. O. Box 247 Bodega Bay, California 94923

e q FEE 1' 07-ENCLOSURE 1

_ ATTENDANCE LIST MCGUIRE APPEAL MEETING JANUARY 18, 1979 DUKE POWER COMPANY J. D. Norton S. K. Blackley J. S. Canady L. C. Dail K. Seidle

_BABOCK & WILC0X W. E. Lawrie NRC - STAFF R. A. Birkel R. Mattson F. Schroeder J. Knight B. Bosnak M. R. Hum F. C. Cherny R. Baer W. R. Butler W. C. Milstead J. W. Shapaker K. D. Desai T. M. Novak R. L. Tedesco R. J. Kiessel F. Litton M. Hartzman K. N. Jabbour H. Cobb E. J. Brown

,