ML19263C615
| ML19263C615 | |
| Person / Time | |
|---|---|
| Site: | Farley |
| Issue date: | 01/30/1979 |
| From: | Robert Lewis NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | Clayton F ALABAMA POWER CO. |
| References | |
| NUDOCS 7902280008 | |
| Download: ML19263C615 (2) | |
Text
[
># #f c UNITED STATES
[
oq'o, NUCLEAR REGULATORY COMMISSION s
_y dN
.f
', y, ( ' g REGloN li
~
r 101 M ARIETT A STRE ET, N.W.
o,
[
%, *... + /
JAN 3 01979 In Reply Refer To:
RII: WAR 50-348/78-27 Alabama Power Company Attn:
Mr. F. L. Clayton, Jr.
Senior Vice President Post Office Box 2641 Birmingham, Alabama 35291 Centlemen:
In reference to our letter to you dated January 22, 1979, the last line of paragraph one reads:
"We have examined your corrective actions and have no further questions at this time."
This line should be corrected to read:
"We will examine your corrective actions and plans during subsequent inspections."
We appreciate your cooperation with us.
Sincerely, E.c. Q R. C. Lewis, Acting Branch Chief Reactor Operations and Nuclear Support Branch cc:
Mr. A. R. Barton Executive Vice President Alabama Power Company Post Of fice Box 2641 Birmingham, Alabama 35291 Mr. H. O. Thrash Manager-Nuclear Generation Alabama Power Company Post Office Box 2641 Birmingham, Alabama 35291 Mr. C. Biddinger, Jr.
Manager-Corporate Quality Assurance Alabama Power Company Post Office Box 2641 Birmingham, Alabama 35291 7002280068
Alabama Power Company JAN 3 019/9 cc:
Mr. W. G. Hairston, III Plant Manager Farley Nuclear Plant Drawer 470 Ashf ord, Alabama 36312 Mr. R. E. Hollands, Jr.
Quality Assurance Supervisor Farley Nuclear Plant Post Office Box U Ashford, Alabama 36312
.