ML19263C550

From kanterella
Jump to navigation Jump to search
Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in QA Insp Rept 99900510/78-04
ML19263C550
Person / Time
Issue date: 01/24/1979
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Curnane R
UNITED ENGINEERS & CONSTRUCTORS, INC.
Shared Package
ML19263C551 List:
References
REF-QA-99900510 NUDOCS 7902260540
Download: ML19263C550 (1)


Text

e Mkp '

UNITE D STAT ES m

/,

o NUCLEAR REGULATORY COMMISSION 3

o REGION IV

$t 611 RYAN PLAZA DRIVE, SUITE 1000 o5

'~[

AR LINGTON, TE X AS 76011 gw f 2 4 JAN 1979 Docket No. 99900510/78-04 United Engineers & Constructors, Inc.

Attn:

Mr. R. A. Curnane, Vice President Project Support Operations 30 South 17th Street Philadelphia, PA 19101 Gentlemen:

Thank you for your letter of December 29, 1978 in response to our letter dated December 4,1978 with an enclosure.

Concerning item D in our Notice of Deviation enclosure, it appears that a deviation does not exist based on the additional information provided in your response.

This additional information will be reviewed during a future inspection.

Concerning item F, this information will be forwarded to NRC/NRR for their consideration during the review of the subject FSAR.

!!e have no further questions at this time. We will review your corrective and preventive actions during a future inspection.

Sincerely,

( kb.,

sUp W.

UldisPotapovs,Chie{t Vendor Inspection Branch 7 9 0 2 2 6 0 5L/o