ML19263C311

From kanterella
Jump to navigation Jump to search
Forwards IE Bulletin 79-01, Environ Qualification of Class IE Equipment. W/List of 11 Systematic Evaluation Program Plants for Which No Action Is Required
ML19263C311
Person / Time
Site: Midland
Issue date: 02/09/1979
From: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Howell S
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
References
NUDOCS 7902210200
Download: ML19263C311 (1)


Text

I TfQ E

[

W UNITED STATES 4

NUCLEAR REGULATORY COMMISSION lt.,

j nj) g REGloN til

'],

p 799 ROoSEVE LT ROAD g cf GLE N E LLYN, ILLINolS 60137 FEBc ai Docket No. 50-329 Docket No. 50-330 Consumers Power Company ATTN:

Mr. Stephen H. Howell Vice President 1945 West Parnall Road Jackson, MI 49201 Gentlemen:

Enclosed is IE Bulletin No. 79-01.

It requires action by you with regard to power reactor facilities with an operating license except for the 11 SEP plants which are listed in Enclosure 3.

This Bulletin is also being sent for information to the 11 SEP plants and all power reactor facilities with a construction permit.

No action or written response is required for construction permit facilities or the 11 SEP plants.

Should you have questions regarding this Bulletin or the actions required of you, please contact this office.

Sincerely, A

James G. Keppler Director

Enclosures:

1.

IE Bulletin No. 79-01 2.

List of IE Bulletins Issued in the past 12 months 3.

List of SEP Plants (11) cc w/encls:

Central Files TIC Director, NRR/DPM Ronald Callen, Michigan Public Director, NRR/ DOR Service Commission PDR Dr. Wayne E. North Local PDR Myron M. Cherry, Chicago NSIC 7902210a0o

U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT REGION III February 8, 1979 IE Bulletin No. 79-01 ENVIRONMENTAL QUAL.IFICATION OF CLASS IE EQUIPMENT Description of Circumstances:

The intent of IE Circular 78-08 was to highlight to all licensees important lessons learned from environmental qualification deficiencies reported by individual licensees.

In this regard, licensees were requested to examine installed safety-related electrical equipment and detamine that proper documentation existed which provided assurance that this equipment would function under postulated accident conditions.

The scope of IE Circular 78-Or' was much broader than other previously issued Bulletins and Circulars (such as IEB 78-04 and IEB 78-02) which addressed specific component failures.

The intent of this Bulletin is to raise the threshold of IE Circular 78-08 to the level of a Bulletin; i.e., action requiring a licensee response.

Inspections conducted to date by the NRC of licensees' activities in response to IE Circular 78-08 have identified one component which licensees have found to be unqualified for service within the LOCA environtrant.

Specificially, unqualified stem mounted limit switches (SMLS), other than those identified in previuusly issued IE Bulletin 78-04, were found to be installed on safety-related valves inside containment at both Duane Amold and Quad Cities 1 and 2 Nuclear Generating Stations.

The unqualified switches are identified as NAMCO Models SL2-C-11, S3CML, sal-31, SA1-32, D1200j, EA-700 and EA-770 switches. According to the tranufacturer, these switches are designed only for general purpose applications and are not considered suitable tievices for service in the LOCA environment.

Consequently, switches are being replaced at th above power plants with qualified componencs.

Also, NRC inspection of component qualification has identified equipir.ent which does not have documentation indicating it is qualified for the LOCA environment.

The inspections have also identified that the licensees' re-review and resolution of problem areas are not receiving the level of attention from all licensees w Because of the protracted schedul are now requesting the power reat expedite completion of their re-r DUPLICATE DOCUMENT by IE Circular 78-08 dated May 31 Entire document previously entered into system under: