05000271/LER-1979-001-03, /03L-0 on 790110:during Normal Operation & Routine Maint,Leak Was Noted Adjacent to Flange on Reactor Water Cleanup Sys Suction Piping.Cause Unknown

From kanterella
(Redirected from ML19263C277)
Jump to navigation Jump to search
/03L-0 on 790110:during Normal Operation & Routine Maint,Leak Was Noted Adjacent to Flange on Reactor Water Cleanup Sys Suction Piping.Cause Unknown
ML19263C277
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 02/08/1979
From: Conway W
VERMONT YANKEE NUCLEAR POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19263C276 List:
References
LER-79-001-03L, LER-79-1-3L, NUDOCS 7902130182
Download: ML19263C277 (2)


LER-1979-001, /03L-0 on 790110:during Normal Operation & Routine Maint,Leak Was Noted Adjacent to Flange on Reactor Water Cleanup Sys Suction Piping.Cause Unknown
Event date:
Report date:
2711979001R03 - NRC Website

text

U. S. NUCLEAR REGULATORY COMMISSION NRC & Ov.M Mb

{7-771 LICENSEE EVENT REPORT LER 79-01/3L CONTROL BLOCK: l l

l l

l l

l (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)

I b

0l@l l@

I vi Tl v1 Yl S 1 l@l O l 0 l - l 0 l 0 0]Ol0 -l0l0l@l4 1]0 0

o i

7 8 9 LICENSEE CODE 14 lb LICENSE NUMBEH 25 26 LICENSE TYPE JO 57 C A T $8 6

CON'T

['g" l L j@ 0] 5 l 0 l 0 l 0 ] 2 l 7 l 1 l@l 0 l 1 l 1 0] 7 9l@l0l2 013l7l9l@

O i

7 d

60 61 DOCKET NUMBER 68 6'3 EVENT DATE 74 75 REPORT D ATE' 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h l

o 2

l o

3 l

See attached sheet l

0 4

l 0

5 l

0 6

l 0

7 l

0 Hll 80 7

8 9 SYSTEY

CAUSE

CAUSE COUP.

VALVE CODE CODE SU8 CODE COUPONENT CODE SU8 CODE SUBCODE l Cl Gj@ l El@ l Cl@ l P lIl P l E l X l X j@ l A @ {@

o o

7 8

9 10 11 12 13 18 19 20 SF OUENTI AL OCCURRENCE REPORT REVISION L E H HO EVENT YE AR REPOHT NO.

CODE TYPE N O.

@ orPont l7l9l

_l l0l0 1l l/l 0l3l L l

_l l0 l

_ 21 22 23 24 26 27 28 29 30 31 32 ACTION FtJTURE fFFECT SHUTDOWN ATTACHMENT NPR D.4 PRIME COYP.

COMPONENT TANEN ACitON ON PL ANT METHOD HOUns SUB MI TT E D FORMbOB.

SUPP LI E R

- MANUFACTURER lC l@l zl@

l z l@

l zl@

l0 0l 0l l

[ Y l@

lNlg lAjg lEl0l6l5lg 13 34 J5 3/

40 43 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS l

The cause of the pipe crack and nozzle crack is unknown at present.

A full l

i o

Li I i l l__.

report will be made when the information,is available.

f i Ld l

E E) L~

i l

1 4

80 1

8 9 S1 5

wPOWEH OTHE R STA TUS ISCOV HY DISCOVF9Y DESCRIPTION NA l

W @ [ Operator Observation l

lE l@ l 0l 9l 9lh i

A TlVITY C

TENT HE L E ASE D OF HELE ASE AMOUNT OF ACTIVITY LOC ATION OF RELEASE NA l

l NA l

W @ l zl@l i

G

/

8 9 10 11 44 45 80 PEHSONNEL 7 XPOSUHLS NUYHiH TYPE DE SCHiP TION -

101010 ]@l :t l@l NA i

i PEnsONNd'Imuns DESCn,PnON@

NoMm H l

1010 Ol@l NA i

80 1

8 9 11 12 i 055 OF OH DAVAGE TO FACILITY TYPE D E SCHIP T ION l

lilolIzl@l NA

[

NRC USE ONLY PUH L i f. TY L. 3 [lLl@DESCulPTION,

l NA i

l l l l,l l ll!

t% SUED 08 69 80 5 7

8 9 10

~

W. F. Conway PHONE.

NA.VE OF PREPARER

LER 79-01/3L VTVYS1 05000271 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES During normal operation, while performing routine maintenance, leakage was observed adjacent to a 2" flange on the Reactor Water Cleanup System suction piping.

Investigation revealed a through wall leak near the piping weld between the 2" flange and the adjoining tee.

Further investigation revealed a through wall leak in the spare nozzle of the Electro Chemical Potential Autoclave located upstream of the 2" flange.

The Reactor Cleanup System was secured, the flange replaced, and the spare nozzle connection repair welded.

Conductivity monitoring of main coolant was shifted to the recirc-ulation loop sample point during the repairs.

The RWCU System was re-turned to service approximately 19 hours2.199074e-4 days <br />0.00528 hours <br />3.141534e-5 weeks <br />7.2295e-6 months <br /> after the discovery. Reactor water chemistry was maintained within Tech. Spec. limits and there were no consequences to the health and safety of the public. A similar inci-dent was reported as RC 77-22/IP.