Discusses Proposed Reg Guide 1.141,Revision 1.High Radiation Signal Should Be Used for Automatic Containment Isolation. Generic Program B-24 Required Diversity in Containment Isolation Signals
ML19262C464
Person / Time
Issue date: 01/17/1980
From: Eisenhut D
Office of Nuclear Reactor Regulation
To: Minogue R
NRC OFFICE OF STANDARDS DEVELOPMENT
References
RTR-REGGD-01.141, RTR-REGGD-1.141 NUDOCS 8002130667
Download: ML19262C464 (2)


Text

~

3

[(g8 "'4 q,

9

^1 A

UNITED STATES f

h q; j NUCLEAR REGULATORY COMMISSION E

WASHINGTON. D. C. 20555

'%.*...J j u,

./

JAN 17 lob 0 MEMORANDUM FOR:

R. B. Minogue, Director, Office of Standards Development FROM:

Darrell G. Eisenhut, Acting Director, Division of Operating Reactors

SUBJECT:

PROPO3ED REGULATORY GUIDE 1.141 (REVISION 1)

"CONTAIMMENT ISOLATI0h PROVISIONS FOR FLUID SYSTEMS" The subject Regulatory Guide has been approved by the ACRS and is currently being scheduled for RRRC action.

As indicated to T. Scarbrough in our previous comments to the Reg. Guide, we agree that a high radiation signal should be used for automatic containment isolation (Section C.4 of the Reg. Guide). There are persuasive arguments to support this requirement in assuring diverse isolatica signals for various accident scenarios, some of which are discussed in NUREG-0578 (Lessons Learned) on pages A-13 through A-15.

Further, we believe that this requirement should be imposed on operating plants as discussed with T. Scarbrough.

The purpose of this memorandum is to advise you that we currently have a generic program - B-24, " Venting and Purging Containments While at Power and Effects on LOCA," a part of which requires diversity in containment isolation signals. Many plants have high radiation as an isolation signal; however, it is not common to have the associated instrumentation safety-grade. We, therefore, will rely on the action of the RRRC on Reg. Guide 1.141 as justi-fication for requiring safety grade equipment. We are so noting in each safety evaluation; and, upon approval from the RRRC, we will go back and send a fomal requirement to licensees.

J E%w Darrell G. Eisenhut, Ac Director Division of Operating Reactors

Contact:

J. Kerrigan X-28129 cc: See page 2 s 00213 0 66 7

~

. cc:

E. Case R. Mattson W. Gammill W. Butler D. Tondi D0R BCs E. Reeves J. Kerrigan J.T. Beard S. Varga G. Lainas B. Milstead R. Scholl W. Pasedag D. Shum E. Adensan T. Scarbrouch L. Barrett F. Witt