ML19262C232

From kanterella
Jump to navigation Jump to search
Forwards LER 80-003/03L-0
Date released: 10/03/2019 Download: ML19262C232


LER 80-003/03L-0:on 800112,while Performing Local Leak Rate Testing During Refueling Shutdown,Path Leakage Through MSIVs for 3 of 4 Main Steam Lines Exceeded Leak Rate Per Tech Specs.Caused by Normal Wear & Erosion
ML19262C234
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 02/04/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19262C234 (2)
Forwards LER 80-003/03L-0
ML19262C231
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 02/04/1980
From: Calhoun J
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19262C231 (1)