a DISTR!BUTIOM:
Cecember la,1976 N'
llRC PCR Local PCR Gray File ORBd4 Rdg.
Docket *lo.:
50 2p V. Stello K. R. Goller T. J. Carter R. Reid G. Zwetzic Ntropolitan Edison Cccoany R. Inaran ATT!!: Mr. R. C. Arnold Attorney, OELD Vice President - Generation OI?,E (3)
P. O. Box 542
- 0. Eisenhut Reading, Pennsylvania 19603 T. B. Abernathy J. R. Buchanan Geritlemen:
ACRS (16)
By letter dated September 14, 1976, we transmitted to you mo:iel technical specifications which addressed inservice inspection and plugging of steam generator tubes.
In our letter we also requested that you submit a proposed amendment to your technical specifications consistent with the model technical specifications. Your response to our request was contained in your letter of flovember 12, 1976.
k'e have reviewed your resoonse and find it unacceptable. The basis for our findinn is that you have significantly revised a nunber of the provisions of the model technical specifications without providino justification for the revisions. These revisions included, but were not limited to:
- 1) A 1 gpm limit on primary-to-secondary stean nerierator leakace was not proposed.
- 2) The 3" samnle size was changed to 1-1/25.
- 3) Provisions for non-randon selection of tubes for inspection were deleted.
4)
Inspection category C-3 was deleted.
- 5) Criteria for acceptability of a 40 conth inspection interval were extensively modified.
- 6) The definition of a " degraded tube" was rodified.
- 7) The schedule for reporting the number of plucced tubes was changed from 15 days to 30 days.
/
- 8) Table a.4-2 of the model technical specifi-caticns was extensively revised.
Because you have not orovided a justification for each of your pronosed revisions, there is no basis for deterninino their acceotability.
Accordincly, you are recuested to resubnit within 20 days of receiot of this letter a revised crocosed arendrent to your technical soecifications 1484 146 1910gn0 6 N
2 vihich is consistent 'sith the model technical seccifications trans-
- nitted by our letter of September 14, 1976.
If there are conditions unique to Three t'ile Island Unit !o. I which necessitate one or core revisions to the nodel technical specifications, each revision should be clearly identified and fully. justified.
Sincerely.
Robert 't.
Peid, Chief Operatino Reactors Branch 4 Division of onerating Reactors cc: See next page 1484 147 j CRS#d2R CRBi4:0'0$~
C M i4:CCR AD-OR:00R f
l j
i e er -
!GZwet99)dn MFairtile Rfeld GGoller 12/d/76
!12/',t/.76 I,12//.9 76 12/M/76 i
l
,.. m F ? u ACC 3. i Re. M 3 : AECI ;i)
- J a.
sa r ew ist = = % m s e
'er i n4. sace:.e
Metropolitan Edison Company cc:
G. F. Trowbridae, Esq.
Shaw, Pittman, Potts, & Trowbridge 1800 M Street, N. W.
Washington, D. C.
20036 GPU Service Corporation Richard W. Heward, Project Manager Thomas M. Crimmins, Jr., Safety and Licensing Manager 260 Cherry Hill Road Parsippany, New Jersey 07054 Pennsylvania Electric Company Mr. R. W. Conrad Vice President, Generation 1001 Broad Street Johnstown, Pennsylvania 15907 Mr. Weldon B. Arehart, Chairman Board of Supervisors of Londonderry Township 2148 Foxiana Road Middletown, Pennsylvania 17057 Miss Mary V. Southard, Chairman Citizens for a Safe Environnent P. O. Box 405 Harrisburg, Pennsylvania 17106 Government Publications Section State Library of Pennsylvania Box 1601 (Ecucation Building)
Harrisburg, Pennsylvania 17126 1484 148