ML19261F276
| ML19261F276 | |
| Person / Time | |
|---|---|
| Site: | Crane |
| Issue date: | 05/29/1974 |
| From: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Arnold R METROPOLITAN EDISON CO. |
| References | |
| NUDOCS 7910250719 | |
| Download: ML19261F276 (1) | |
Text
~*
.w 4
UNITED ST A TES
- T "-%,
ATOMIC ENERGY COMMISSION f.
I d/ ' -
DIR E CTOR A TE O F R E G U L A TO H V OPE R A TIO N S
! ~
REGION 1 1
d/
10 631 P ARK AVENUE 4
/5 KING oF PRUSSI A, PENNSYLV ANI A 194C6 l
I 4,y_ gd*
May 29, 1974 i
l Docket No. 50-289 Metropolitan Edison Company Attention:
Mr. R. C. Arnold Vice President P. O. Box 542 Reading, Pennsylvania 19603 I
Gentlemen:
The enclosed DRO Bulletin No. 74-6 " Defective Westinghouse Type W-2 Control Switch Component" is sent to provide you with information obtained during recent RO inspections. This information may have applicability at your facility (ies). The action requested on your part is identified in the enclosed Bulletin.
If you have any questions on the contents of this Bulletin, please do not hesitate to contact us.
Sincerely, O
f) ^- -
c Jam P. O'Reilly Dir6ctor
Enclosure:
DRO Bulletin No. 74-6 cc:
Mr. J. G. Herbein, Station Superintendent Mr. R. W. Heward, Project Manager, GPUSC bec: B0 Files
~
jbR Central Files PDR i'
g Reg. Rdg. Room i
State of Pennsylvania j
//_
4