./g. aF u

L Victor Benaroya, Chief, Iffinent Treatment Systems Branch, L CHANGE IN THREE MILE ISLAND, UNIT 1 TECHNICAL SPECIFICATION ACTIVITT RELEASE EATES The activity release rates for noble gases and radiciodine for the Three Mile Island Technical Specifications were determined using the site boundary I/ from the July 11 Edition of the SIR (1.3 x 10-5,,,j,3) g and the I/q at the fr:m the FES (1.6 x 10 sec/m3). These release rates have been provided to the app 14e==t as part of our input to his Technical Specifientin==.

Da September 20, we met with the applicant to discuss our input to the Technical Specifications. As a result of discussions between E. Markas and K. Woodward (Pickar & Love)

E. Markee changed the values of the I/q that he intends to..r M E tot 4

I/ }N.G.

8 x 10 Q

I/ )I-131 9.5 x 10 Q

The I/q)y_y37 to be used in the t=*h=4*=1 specifications has been corrected for cloud depletion of 13%; i.e. I/q)I-131 8.3 x 10-7 It should be noted that ah==

ng the I/q valv, et this point in the review prossess additional work for as and erold khst rises as in a position of =h=*=ww*

  • =*=r= changing our w-1== ion of a previously===ee*ptable radweste systas; e.g. Peach Bottom. We contend that when the I/o values ars =adified, the rational for the change should be documented and distributed to the Staff members who see the I/q in their evaluations.

Ihoenis Smith, Nuclear Engineer Effluent Treatment Systems Branch Directorate of Tfran=ing ec:

1. Tedesco DISTRIBUTION:

Subject File ~* ETSB Reading T %nA4mo

_.EyB{L yj,gl,,,

emcz,

h:ce SURMAME >

DATE )

Form AEC-518 (Rev. 9-55) AECM 0240

.o.- to--s t us-i uscs

'l910170 77