ML19261E889

From kanterella
Jump to navigation Jump to search
Insp Repts 50-289/70-05 & 50-320/70-04 on 700618.Summary of Mgt Meeting W/Util & B&W in Lynchburg,Va Re B&W QA Insp,Ref IE Insp Repts 50-289/70-03 & 50-320/70-03
ML19261E889
Person / Time
Site: Crane  
Issue date: 07/02/1970
From: Heishman R, Howard E, Hunnicutt D
US ATOMIC ENERGY COMMISSION (AEC)
To:
Shared Package
ML19261E880 List:
References
50-289-70-05, 50-289-70-5, NUDOCS 7910170946
Download: ML19261E889 (3)


Text

a U. S. ATOMIC ENERGY CCMMI.sSION REGION I DIVISION OF COMPLDNCE Repcrt of Inspection C0 Report Nos. 289/70-3 320/70-4 1.a nsee:

Metropolitan Edison Company (Met Ed)

(Three Mile Island Uaits No. 1 and 2)

License Nos. CPPR-40 and CPPR-66 uate of Inspection:

June 18, 1970 Date of Previous Inspection:

May 26-28, 1970 Inspected by:

'ht & & f-7/4 /70 D. M. Hunnicutt, Reactor Inspector (Principal)

' Ddte Y"/ 00

~

R. F. Heishman, Reactor Inspector Date Reviewed by:

J 6f T

7[ / 70~

E. M. Howard, Senior Reactor Inspector

'Date Proprietary Information:

NONE SCOPE The purpose of this management meeting was to discuss with Met Ed and B&W tM comments and findings obtained during the 3&W QA inspection (C0 Report Nor.

289/70-3 and 320/70-3). The meeting was held in the 36W office, Lynchburg, Virginia.

The significant findings of the inspection were reviewed with Met Ed and B&W corporate and staff personnel.

The specific areas of concern were discussed in detail by Mr. Heishman. B&W and Met Ed were responsive to the C0 comments and indicated that corrective action would be initiated at the earliest date practical.

A.

Meeting Attendees 1483 104 BsW W. H. Rawand, Vice President and General Manager, NPGD H. F. Dobel, Manager, QA R. E. Braumiller, QA Representative s

E. G. Ward, Project Manager, TMI 1 and 2 D. W. Ment:;omery, Manager, Nuclear Systems Engineerin 0170 C. R. Powers, QA Representatire jh