ML19261E106

From kanterella
Jump to navigation Jump to search
Responds to 790328 Request for Withholding of Rept, Accelerated Aging Procedure (cc-323.74-3A). Review Based on 10CFR2.790 Indicates Insufficient Justification for Withholding
ML19261E106
Person / Time
Site: River Bend  
Issue date: 05/17/1979
From: Varga S, Vargo S
Office of Nuclear Reactor Regulation
To: Humphreys L
GULF STATES UTILITIES CO.
References
NUDOCS 7907050136
Download: ML19261E106 (3)


Text

N $ G / W A'.

- 8[pa "%q(0, UNITED STATES

^

NUCLEAR REGULATORY COMMf310N

-l wAsmucToN. o. c. zosss

  • q f

e' MAY 171979 Docket Nos.: 50-458 50-459 Mr. L. L. INmphreys Senior Vi n President Energy Development Gulf States Utilities Company P. O. Box 2951 Beaumont, Texas 77704

Dear Mr. Humphreys:

SUBJECT:

REQUEST FOR WITHHOLDING INFORMATION FROM PUBLIC DISCLOSURE Your letter of March 28, 1979, and its attacheC affidavit of Gould, Inco, orated, submitted for our review the qualification repc-t for the Gould 480 vc' mtor control centers. This included a supplemental report entitled " Accelerated Aging Procedure (CC-323.74-3A)," which Gould, Inc., requests to be withheld from public disclosure pursuant to Section 2.790 of 10 CFR Part 2.

Gould states in its affidavit that the information in the supplemental report consists of a method of demonstrating that aging does not lower the seismic withstandability of its equipment, and that unrestricted disclosure of this material is likely to cause substantial hann to its competitive position.

We have reviewed the application for withholding and the related supplemental report based upon the requirements and criteria of Section 2.790 of 10 CFR Part 2 and have concluded that they do not provide sufficient justification for us to find that the information should be withheld. We find that the supple-mental report contains no specific test results and does not reveal the specific capabilities or limitations of any specific equipment. Rether, the supplemental report provides a general outline of the order for the accelerated aging pro-cedure which will be followed on electromechanical devices removed from actual field use, as well as for new devices from stock, in order to qualify the devices to the equirements of IEEE Standard 323-1974. Such information is not of the type typically recognized by the NRC staff as being proprietary and does not satisfy the requirements of 10 CFR 2.790. Therefore, the request to wichhold tne supplementa.1 Gould reporc CC-323.74-3A is denied. Additionally, we find that the aff'...vit of Gould, Incorporated is not in conformity with the requirements of Section 2.790(b) of the Commission's regulations because it is conclusory in nature and does not address the considerations of paragraph (b)(4) with sufficient specificity to enable the Commission to have a basis for its determination under paragraph (b)(3)(i).

790705013ro

?86 lid 7)

Mr. L. L. Humphreys MAY 171979 In accordance with Section 2.790(c) of 10 CFR Part 2, the information sought to be withheld will be placed in the Comission's Public Docur. erit Room 30 days after the date of this letter unless you seek to withdraw it before that time.

Sincerely, cvf Steven A. Varga, Chief Licht Water Reactors Branch No. 4 Division of Project Management cc: See next page 9

e

".).UQ/

$lf L

I)

,j 't t

I

?

9' Gulf States Utilities Company 3-ccs:

W iroy B. Conner, Jr.

sq.

t 1747 Pennsyhania Avenue, fl. W.

~ ~-

Washington, D. C.

20006 Mr. J. E. Booker Safety ard Licensing Culf States Utilities Company P. O. Box 2951 Beaciont, Texas 77704

[.Y '

Stanley Plettman, Esq.

Orgrin, Bell & Tucker e

Beat.nont Savings Building Beau.lont, Texas 77701 Karin P. Sheldon, Esq.

Sheldon, Harmon & Roisman 1025 15th Street, N. W.

Washington, D. C. 20005 cr.-

William J. Guste, Jr. Esq.

Attorney General State of Louisiana r:

P. O. Box 44005 i

State Capitol Baton Rouge, Louisiana 70804 Richard M. Troy, Jr., Esq.

~

Assistant Attorney General in Charge State of Louisana Departmer+ of Justice 234 Loyola Avenue New Orleans, Louisiana 70112 y'-

f"':,:

W:

EJ.

y.

O t

S b.5 -

i

}

~

uu s

  • .*1pg.a o.

Y

.m y