ML19261B823
| ML19261B823 | |
| Person / Time | |
|---|---|
| Site: | Big Rock Point File:Consumers Energy icon.png |
| Issue date: | 01/19/1979 |
| From: | Davis A NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Dewitt R CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.) |
| Shared Package | |
| ML19261B824 | List: |
| References | |
| NUDOCS 7903070297 | |
| Download: ML19261B823 (2) | |
See also: IR 05000155/1978014
Text
V
e
j,[
Og
UNIT E D STATES
[,,
NUCLE AR REGULATORY COMMISSIOfJ
I
'
>
,
3 f(;' J ;;
,
.
ntoioN m
h
,,
, f
j
793 HOo3E VF L T Pr ,o
r
. e'
t o t t N E L t V N. s L LIN O'S 0 013 7
0....
"
JAN 1f 7
Docket No. 50-155
Consumers Power Company
ATTN:
Fx. R. B. DeWitt
Manager of Nuclear
Plant Operations
212 West Michigan Avenue
Jackson, MI
49201
Gentlemen:
This refers to the . inspection conducted by Mr. M. C. Schumacher
of this office on December 11-14, 1978, of activities at Big
Rock Point Nuclear Plant authorized by NRC Operating License No.
DPR-6 and to the discussion of our findings with Mr. Hartman and
othcrs of your staff at the conclusion of the inspection.
The enclosed copy of our inspection report identifies areas
examined during the inspection. Within these areas, the
inspection consisted of a selective examination of procedures
and representative records, observations, and interviews with
personnel.
No items of noncompliance with NRC requirements were identified
during the course of this inspection.
In accordance with Section 2.790 of the NRC's " Rules of
Practice," Part 2, Title 10, Code of Federal Regulations, a
copy of this letter and the enclosed inspection report will
be placed in the NRC's Public Document Room, except as follows.
If this report contains information that you or your contractors
believe to be proprietary, you must apply in writing to this
office, within twenty days of your receipt of this letter, to
withhold such information from public disclosure.
The
application must include a full statement of the reasons for
which the information is considered proprietary, and should be
prepared so that proprietary information identified in the
application is contained in an enclosure to the application.
790307 oM7
.
Consumers Power Company
-2-
-
ulp,-).y,
p .,
as s
We will gladly discuss any questions you have concerning this
inspection.
Sincerely,
.
l .?
A
A.
B. Davis, Chief
Fuel Facility and
Material Safety Branch
Enclosure:
IE Inspection
Rpt No. 50-155/78-14
cc w/ encl:
Mr. C. J. Hartman, Plant
Superintendent
Central Files
Reproduction Unit SRC 20b
Local PDR
Ronald Callen, Michigan Public
Service Commission
Anthony Roisman, Esq.,
Attorney