ML19261A368
| ML19261A368 | |
| Person / Time | |
|---|---|
| Site: | Point Beach |
| Issue date: | 12/06/1978 |
| From: | Davis A NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Burstein S WISCONSIN ELECTRIC POWER CO. |
| Shared Package | |
| ML19261A369 | List: |
| References | |
| NUDOCS 7901110350 | |
| Download: ML19261A368 (2) | |
See also: IR 05000266/1978018
Text
T
e
'
TE/R
-
g
4,
UNITED STATES
'
. , .
?t
NUC LE AR REGULATORY COMMISSION
f I, ([ .I
REGION til
- j
j
799 RooSEVE LT ROAD
,
$'s,
y
&
G LEN E LLYN, ILLINOIS 60137
.....
DEC 0 6 378
-
Docket No. 50-266
Docket No. 50-301
Wisconsin Electric Power Company
ATTN:
Mr. Sol Burstein
Executive Vice President
Power Plants
231 West Michigan
Milwaukee, WI 53201
Gentlemen:
This refers to the inspection conducted by Mr. L. R. Greger of
this office on October 4-6 and 24-27, 1978, of activities at the
Point Beach Nuclear Plant authorized by NRC Licenses No. DPR-24
and No. DPR-27 and to the discussion of our findings with Mr. Reed
and others of your staff at the conclusion of the inspection.
The enclosed copy of our inspection report identifies areas
examined during the inspection. Within these areas, the
inspection c^nsisted of a selective examination of procedures
and representative records, observations, and interviews with
personnel.
No items of noncompliance with NRC requirements were identified
during the course of this inspection.
In accordance with Section 2.790 of the NRC's " Rules of
Practice," Part 2, Title 10, Code of Federal Regulations,
a
copy of this letter and the enclosed inspection report will
be placed in the NRC's Public Document Room, except as follows.
If this report contains information that you or your contractors
believe to be proprietary, you must apply in writing to this
office, within twenty days of your receipt of this letter, to
withhold such information from public disclosure. The
application must include a full statement of the reasons for
which the information is considered proprietary, and should be
prepared so that proprietary informacion identified in the
application is contained in an enclosure to the application.
m
.)..I
3
350
.
.
DEC 06 JTS
Wisconsin Electric Power
-2-
Company
-
We will gladly dit uss any questions you have concerning this
inspection.
Sincerely,
.
O
.-
-
OBA-
A. B. Davis, Chief
Fuel Facility and
Materials Safety Branch
Enclosure:
IE Inspection
Rpts No. 50-266/78-18
and No. 50-301/78-21
cc w/ encl:
Mr. G. A. Reed, Manaher
Central Files
Reproduction Unit NRC 20b
Local PDR
-