ML19260D667

From kanterella
Jump to navigation Jump to search
Forwards LER 80-008/03L-0
Date released: 10/01/2019 Download: ML19260D667


LER 80-008/03L-0:on 800109,while Performing Surveillance, Core Spray Valve 14-MOV-12B Failed to Open as Required. Caused by Torque Switch Not Being Bypassed for Sufficient Time Period.Adjusted Torque & Limit Switches
ML19260D671
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 02/08/1980
From: W. Verne Childs
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19260D671 (2)
Forwards LER 80-008/03L-0
ML19260D666
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 02/08/1980
From: Leonard J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19260D666 (1)