DUKE POWER COMPANY Powen Bt:It.orso 422 Sot:Tu Circacu Srazzi, CitAatorTz. N. C. asa4a WI LLI A M O. Pa 7 st E R, J R.

Acc a ci =ce January 31, 1980 c. c -c~c: aa ca 704 c.

$ t ta ns P o o h c'< o g 3 7 3-d0 0 3 Mr. Harold R. Denton, Chief Office of Nuclear Reactor Fegulation U.S. Nuclear Regulatory Commission Washington, DC 20555 Attention:

Mr. R. L. Baer, Chief Light Water Reactor Project Branch No. 2 Re: McGuire Nuclear Station Docket Nos..

50-369 and -370

Dear Sir:

As requested by Mr. Brian K. Grimes' letter of November 29, 1979, evacua-tion time estimates for evacuation of various areas around the :!cGuire Nuclear Station are provided in Attachment 1.

A color overlay map of the site is provided as Attachment 2.

Ve y truly yours,,'

I

/

s a./K William O. Parker, Jr ROS/sch Attachments cc: County Civil Preparedness Agency C!ecklenburg, Gaston, Iredell, Lincoln, York)

I g6wY6 y,

hp y 9

s, 0

$ pth' g

/p,""**e f

s r,

f" i

19d]

192

%d/

f

'^'

th Anniversary

  • %g" *'" '# l 6002120 $23

DUKE POWER COMPANY McGuire Nuclear Station Evacuation Time Estimates

}h^)

Evacuation time estimates (including notification) fnr the areas identified on de attached site map are orovided below:

1.

Area 1 includes the WSW, SW, SSW, S, SSE, SE, ESE and the East sectors.

Population total is 318. There are no special facilities within this area. There are no population concentrations in this area.

Notification Time:

15 minutes Best Estimate Evacuation Time:

20 minutes Adverse Weather Evacuation Time:

35 minutes Evacuation Confirmation Time:

30 minutes 2.

Area 2 includes the ENE, NE, NNE, N, NNW, NW, WNW and tne West sectors.

Population total is 3,765 of which 3,525 are peak attendance at recreational areas on Lake Norman. There are no special facilities si thin this area. Population concentrations are at or near the 2 mile line.

Notification Time: (see note 3) 30 minutes Best Estimate Evacuation Time:

45 minutes Adverse Weatner Evacuation Time:

60 minutes Evacuation Confirmation Time:

45 minutes 3.

Area 3 includes the SSE, SE, ESE, and East sectors, 2 miles from the st3 tion out to 5 miles from the station. Populaticn total is 1,413 with no peak attendance ceople. There are no Special Facilities in this area. Thece are no population concentrations in this area.

Notification Time:

15 minutes Best Estimate Evacuation Time:

30 minutes Adverse Weather Evacuation Time:

45 minutes Evacuation Confirmation Time:

30 minutes 4

Area 4 includes the ENE, NE, NME anc North sectors, 2 miles from the station out to 5 miles from the station.

Population total is 10,185 of wnicn 3,931 are peak attendance at recreational areas an Lake Norman. There are no special facilities in this area. There are no population concentrations in this area.

Notification Time:

30 minutes Best Estimate Evaucation Time:

55 minutes Adverse Weather Evacuation Time:

70 minutes Evacuation Confirmation Time:

45 minutes

)9 ]

2 5.

Area 5 includes the NNW, NW, WNW, and the West sectors, 2 miles from the station out to 5 miles from the station.

Population total is 2,573 of wnich 1,466 are peak attenance at recreational areas on Lake Norman. There are two schools in the area.

There are no population concentrations in this area.

Notification Time: (see note 3) 30 minutes Best Estimate Evacuation Time:

55 minutes Adverse Weather Evacuation Time:

70 minutes Evacuation Confirmation Time:

45 minutes 6.

Area 6 includes the WSW, SW, SSW, and South sectors, 2 miles from the station out to 5 miles from the station.

Population total is 1,147.

There are no special facilities in this area and there are no population concentrations in area 6.

Notification Time:

15 minutes Best Estimate Evacuation Time:

30 minutes Adverse Weather Evacuation Time:

45 minutes Evacuation Confimation Time:

30 minutes 7.

Area 7 includes the SSE, SE, ESE, and East sectors, 5 miles from the station out to 10 miles from the station.

Population total is 21,704 of which 3,738 are peak attendance at recreational areas on Lake Norman.

There is cne hospital in this area (primarily geriatrics) with a normal patient loac of 330 and a staff of 200 during the day anc 45 on shift and weekends.

There are 5 schools in this area and one State Prison Camp.

Notification Time:

15 minutes Best Estimate Evacuation Time:

45 minutes Adverse Weather Evacuation Time:

65 minutes _

Sest Estimate Evacuation Time, Special Facilities: 105 minutes Best Estimate Evacuation Time, Adverse Weather for Special Facilities:

135 minutes Evacuation Confirmation Time:

60 minutes 3.

Area 8 includes the ENE, NE, NNE and North sectors, 5 miles from the station out to 10 miles from the station. Population total is 19,35E of wnich 7,152 are peak attendance at recreational areas on Lake Norman.

There are two scnools and one College in this section and no special facilities.

Notification Time:

15 minutes Eest Estimate Evacuation Time:

45 minutes Adverse Weather Evacuation Time:

65 minutes Evacuation Confirmation Time:

45 minutes

)?A]

i$3

3 9.

Area 1 includes the NfM, NW, WNW and the West sectors, 5 miles from the station out to 10 n,iles from the station. Population total is 8,094 of which 2,823 are peak attendance at recreational areas on Lake Norman. There are two schools in this sector and no special facilities.

Notification Time:

15 minutes Best Estimate Evacuation Time:

45 minutes Adverse Weather Evacuation Time:

65 minutes Evacuation Confinnation Time:

45 minutes

10. Area 10 includes the WSW, SW, SSW and the South sectors, 5 miles from the station out to 10 miles from the station.

Population total is 24,635 of which 663 are peak attendance at recreational areas on the Catawba River.

There are 5 schools in the area and two populatior concentrations located near the 10 mile zone.

Notification Time:

15 minutes Best Estimate Evacuation Time:

45 minutes Adverse Weather Evacuation Time:

55 minutes Evacuation Confirmation Time:

60 minutes NOTES 1 1.

Population figures based on 1970 census and population projections to year 2015 for peak attendance at recreation areas on Lake Norman anc tne Catawca River and to year 2000 for permanent residences cut to 10 miles from tne s ta ti on. Taken from McGuire FSAR Vol. I Figures 2.1.3-22 anc 2.1.3=5, Rev. 7 Totals exclude special facilities populations.

2.

Evacuation times based on studies of population density, road ca:acity to evacuation sites outside of the 10 mile zone, nearness of volunteer and municipal agencies responsible for the actual evacuation planning and experience and coments on the area Civil Preparedness Coordinator of N.C.

Primary evacuation methodsis via private automobile as tne area witnin McGuire's 10 mile Emergency Planning Zone is primarily a rural area inhabitated by a population not decendent on mass transpcrtation facilities.

Evacuation times for sectors outside of the 2 mile zone, incorpcrate transit times for personnel passing through to reacn tneir predesignatec evacuation site, thereby increasing traffic on evacuation routes and tne cistance to be traveled to exist evacuation zone.

3.

Notification times are included for each 180 deg. and 90 deg. sector.

Present means of notification is via local radio, TV and weatner bureau facilities.

Notification is also via police (County, municipal, and State) anc iccal fire cecartments utilizing sirenes, bu11norns and house to nouse wardng.

Nc ti fi ca-tion times for fishing and recreati:nal boating on Lake Norman and river areas assumes that a lake and river searcn and direct contact will be.ade utilizing Colice, coast guard auxiliary and ccm::any boats to ccmplete tnis notification.

Rese times are calculated, basec cn county anc state personcei teinc cn reacy standby to perform required notification.

i,O'l 9b

4 4.

There are no provisicr.s in the North Carolina Emergency Response Plan to evacuate people to evtcuation centers within the 10 mile zone for any purpose.

Evacuation of any area would proceed to predesigned evacuation centers located outside the 10 mile Emergency Planning Zone.

Evacuation times are calculated to evacuate only the required area, 2 mile, 5 mile,10 mile, and not for evacuees to physically reach a designated evacuation site 5.

Evacuation of schools is not included in Special Facilities. Bus and private auto transportation out of an evacuation zone from the schools in session or during special activities is provided and are close at hand.

6.

In reference to Arca 7, data shown concerning hospital is current as of January 15, 1980.

7.

Local civil defense acencies were consulted in precaring the above evacua-tion time estimates.

There were no areas of disacreerent.

1941 197

DGE PO'.;ER C0!T.in'

'!cGitire 'Juclear Sta tion

.\\ t ta ch men t 2 S i t e l'1n O^l

/,s