Consumers Power Company

'i General O'f.com 212 West M.c hegan A venue. Jat h s.;n, M c higen 49201. Aten Code S17 7 H R-O S SO February 5,1980 Director, Nuclear Reactor Regulation Att Mr Dennis L Zie= ann, Chief Operating Reactors Branch No 2 US Nuclear Regulatory Conmission Washington, DC 20555 DOC':ET 50-155 - LICENSE DPR BIG ROCK POINT PLANT - RECIRCULATING PG'? TRIP SYS2 M Consumers Power Company letter dated April 9, 1979 responded to an NRC request (letter dated January 8,1979) to commit to the installation of a recirculating pump trip (RPT) system.

Our April 9,1979 letter com=itted to the installation of the RPT at Big Rock Point during the refueling outage scheduled to begin in late February, 1981.

As requested by the NRC Staff, Consumers Power revises our commitment so that the RPT vill be installed during the 1980 refueling outage (schedulad to begin October 25, 1980).

David P Hoffhan (Signed)

David P Hoffman Nuclear Licensing Administrator CC JCKeppler, L'SNRC 1934 208 s o n2 0 s o 03