ML19260C251

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Repts 50-277/79-08 & 50-278/79-09 on 790226,28 & 70305-07 & Notice of Violation.Notice of Violation Withheld (Ref 10CFR2.790)
ML19260C251
Person / Time
Site: Peach Bottom  
Issue date: 09/14/1979
From: Martin W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Daltroff S
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
Shared Package
ML19260C246 List:
References
NUDOCS 7912260115
Download: ML19260C251 (2)


See also: IR 05000277/1979008

Text

>

UNITED STATES

.

g* *"'8 9

0

,

NUCLEAR REGULATORY COMMISSION

+

g

REGION I

j ? ,s

631 PARK AVENUE

i

g

KING OF PRUSSI A, PENNSYt.V ANI A 19406

.....

SEP 14 Uc

Docket Nos. 50-277

50-278

Philadelphia Electric Company

ATTN:

Mr. S. L. Daltroff

Vice President, Electric Production

2301 Market Street

Philadelphia, Pennsylvania 19101

Gentlemen:

Subject:

Inspection 50-277/79-08 and 50-278/79-09

This refers to the inspection conducted by Mr. R. Bailey of this office

on February 26, 28, and March 5-7, 1979, at Peach Bottom Atomic

Power Station, Delta, Pennsylvania, of activities authorized by NRC

License Nos. DPR-44 and DPR-56 and to the discussions of our findings

held by Mr. Bailey with Mr. W. Ullrich of your staff at the conclusion

of the inspection.

Areas examined during this inspection are described in the Office of

Inspection and Enforcement Inspection Report which is enclosed with this

letter.

Within these areas, the inspection consisted of selective

examinations of procedures and representative records, interviews with

personnel, measurements made by the inspector, and observations by the

inspector.

Our inspector also verified the steps you have taken to correct the item

of noncompliance brought to your attention in a letter dated August 11,

1978.

We have no further questions regarding your action at this time.

Based on the results of this inspection, it appears that certain of your

activities were not conducted in full compliance with NRC requirements,

as set forth in the Notice of Violation, enclosed herewith as Appendix

A.

These items of noncompliance have been categorized into the levels

as described in our correspondence to you dated December 31, 1974.

This

notice is sent to you pursuant to the provisions of Section 2.201 of the

NRC's " Rules of Practice", Part 2, Title 10, Code of Federal Regulations.

1616

176

,

,

o

7912260

g,

>

.

.

.

.

Philadelphia Electric Company

2

SEP 14 1979

Section 2.201 requires you to submit to this office, within twenty (20)

days of your receipt of this notice, a written statement or explanation

in reply including:

(1) corrective steps which have been taken by you

and the results achieved; (2) corrective steps which will be taken to

avoid further items of noncompliance; and (3) the date when full com-

pliance will be achieved.

In accordance with Section 2.790(d) of the NRC's " Rules of Practice",

Part 2, Title 10, Code of Federal Regulations, documentation of findings

of your control and accounting procedures for safeguarding special

nuclear materials and your facility security procedures are exempt from

disclosure; therefore, the enclosures to this letter, and your response

'

to this letter will.not be placed in the Public Document Room and will

receive limited distribution.

Should you have any questions concerning this insp ction, we will be

pleased to discuss them with you.

Sincerely,

0 Q .-

Y OV'

n

~Q/,,m / ;- ? '_/c L %

Walter G. Martin, Chief

Safeguards Branch

Enclosures:

1.

Appendix A, Notice of Violation (Contains 2.790 Information)

2.

Office of Inspection and Enforcement Inspection Report Numbers

50-277/79-08 and 50-273/79-09 (Contains 2.790 Information)

cc:

W. T. Ullrich, Station Superintendent

J. D. McGoldrick, Manager, Claims Division, Legal Department

Troy B. Conner, Jr. , Esquire

Eugene J. Bradley, Esquire

Raymond L. Hovis, Esquire

Warren Rich, Esquire

1616 177

.