ML19260A497
| ML19260A497 | |
| Person / Time | |
|---|---|
| Site: | Berkeley Research Reactor |
| Issue date: | 10/10/1979 |
| From: | Book H NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V) |
| To: | Schrock V CALIFORNIA, UNIV. OF, BERKELEY, CA |
| Shared Package | |
| ML19260A492 | List: |
| References | |
| NUDOCS 7911210363 | |
| Download: ML19260A497 (2) | |
See also: IR 05000224/1979004
Text
4
g" "' 4
L
f1
9[o
UNITED STATES
'g
NUCLEAR REGULATORY COMMISSION
y )'
g
nEGION V
4y p G j
7n G
.
([,
d
8
1990 N. CALIFORNIA BOULEVARD
\\ +#
o',
SUITE 202, WALNUT CREEK PLAZA
.g
WALNUT CREEK, CALIFORNIA 94596
October 10, 1979
Docket flo. 50-224
.
University of California
Berkeley, California 94720
Attention:
Professor Virgil Schrock
Reactor Administrator
-
Gentlemen:
Subject:
NRC Inspection of TRIGA Facility
This refers to the inspection conducted by Mr. R. Thomas of this office
on August 16-17, 1979 of activities authorized by NRC License No. R-101,
and to the discussion of our findings held by Mr. Thomas with you and
other members of your staff at the conclusion of the inspection.
Iceas examined during this inspection are described in the enclosed
inspection report. Within these areas, the inspection consisted of
selective examinations of procedures and representative records, in-
terviess with personnel, and observations by the inspector.
Based on the results of this inspection, it appears that one of your
activities was not conducted in full compliance with NRC requirements,
as set forth in the Notice of Violation, enclosed herewith as Appendix A.
This item of noncompliance has been categorized into a level as de-
scribed in our correspondence to all NRC licensees dated December 31,
1974.
This notice is sent to you pursuant to the provisions of Section 2.201,
of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal
Regulations. Section 2.20i requires you to submit to this office,
within twenty (20) days of your receipt of this notice, a written state-
ment or explanation in reply including (1) corrective steps which have
been taken by you and the results achieved; (2) corrective steps which
will be taken to avoid further violations; and (3) the date when full
compliance will be achieved.
1380
172
i
7911210 3 b3
October 10, 1979
University of California, Berkeley
-2-
,
.
In accordance with Section 2.790 of the NRC's " Rules of Practice,"
Part 2, Title 10, Code of Federal Regulations, a copy of this letter and
the enclosed inspection report will be placed in the NRC's Public
Document Room.
If this report contains any information that you believe
to be proprietary, it is necessary that you submit a written application
to this office, within 20 days of the date of this letter, requesting
that such information be withheld from public disclosure. The application
must include a full statement of the reasons why it is claimed that the
information is proprietary. The application should be prepared so that
any proprietary information identified is contained in an enclosure to
the application, since the application without the enclosure will also
be placed in the Pubiic Document Room.
If we do not hear from you in
this regard within the specified period, the report will be placed in
the Public Document Room.
Should you have any questions concerning this inspection, we will be
glad to discuss them with you.
Sincerely,
t(f hbic.
n~v
I H. E. Book, Chief
Fuel Facility and
Materials Safety Branch
Enclosures:
A.
Appendix A - Notice of Violation
B.
IE Inspection Report
No. 50-224/79-04
1380
173
\\