Forwards QA Program Insp Rept 99900248/79-01 on 790129-0202 & Notice of Deviation
ML19259C621
Person / Time
Issue date: 02/14/1979
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Freed J
UNION PUMP CO.
Shared Package
ML19259C616 List:
References
REF-QA-99900248 NUDOCS 7908070188
Download: ML19259C621 (2)


Text

ga "849 UNITE D STATES

  1. o NUCLEAR REGULATORY COMMISSION "f-REGION IV

[

p('

3

=s a

611 RYAN PLAZA DRIVE, SUITE 1000 kYf?

ARLINGTON, TEXAS 76011

    • )[. +

14 FEB 1979 Docket No. 99900248/79-01 Union Pump Company ATTN: Mr. J. B. Freed President 87 Capital Avenue Battle Creek, Michigan 49016 Gentlemen:

This refers to the QA Program inspection conducted by Mr. L. E. Ellershaw of this office on January 29 - February 2,1979, of your facility at Battle Creek, Michigan, associated with the manufacture of nuclear pumps and to the discussions of our findings with you and members of your staff at the conclusion of the inspection.

This inspection was made to confirm that, in the areas inspected, your QA Program is being effectively implemented. The inspection effort is not designed to assure that unique quality requirements imposed by a e Jstomer are being implemented; nor to assure that a specific product, t.omponent or service provided by you to your customers, is of acceptable quality. As you know, the NRC requires each of its licensees to assume full responsibility for the quality of specific products, components or services procured from others. You should therefore not conclude that the NRC's inspection exempts you from inspections by an NRC licensee or his agents nor from taking effective corrective action in response to their findings.

Areas examined and our findings are discussed in the enclosed report.

Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.

Curing the inspection it was found that the implementation of your QA Program failed to meet certain NRC requirements.

The specific findings and references to the pertinent requirements are identified in the enclosures to this letter.

Please provide us within thirty (30) days of your receipt of this report a written statement containing, (1) a description of steps that have been or will be taken to correct these items, (2) a description of s'aps that have been or will be taken to prevent recurrence, and (3) the date your corrective actions and preventive measures were or wil? be completed.

2100 308 1kfQ%W 7 9 080 7 0(gg

gggsgsp,

Union Puthp Company In accordance with Section 2.790 of the Commission's " Rules of Practice,"

Part 2, Title 10, Code of Federal Regulations, a copy of this letter with cnclasure and your reply, together with the enclosed inspection report will be placed in the Commission's Public Document Room.

If this report contains any information that you believe to be prnprietary, it is necessary that you make a written.gplication within thirty (30) days to this office to withhold such information from public disclosure Any such application must include a full statement of the reasons on the basis of which it is claimed that the infomation is proprietary, and should be prepared so that proprietary information identified in the application is containti in a separate part of the document.

If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.

Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely, I

r 0

$./hlf Uldis Potapovs', Chic,f Vendor Inspection Branch

Enclosures:

1.

Notice of Deviation 2.