ML19259C195

From kanterella
Jump to navigation Jump to search
Final Rept 79/01-5PS-491/492/493:weld Fittings W/Lot Number W6719 Contained Erroneously Identified High Carbon Steel Matl That Could Crack When Being Welded.All Matl Returned to Vendor on 790412
ML19259C195
Person / Time
Site: Cherokee  
Issue date: 05/11/1979
From:
DUKE POWER CO.
To:
Shared Package
ML19259C194 List:
References
79-01-5PS, 79-1-5PS, NUDOCS 7906140336
Download: ML19259C195 (1)


Text

.

3 Report No.: 79/01-SPS-491/492/493 Report Date: May ' ',1979 Facility:

Cherokee Nuclear Station Identification of Deficiency: Recall of pipe fittings Description of Deficiency:

Tube Turns Division, Louisville, Kentucky advised Duke Power Company that welding fittings bearing tot Number W6719 contained erroneously identified high carbon steel material.

Analysis of Safety Imolications:

Cracks will occur when high carbon material is welded; however, it is possible that cracks would go undetected.

Corrective Action:

All material was shipped from Cherokee to Tube Turns on April 12, 1979.

==

Conclusion:==

All required action completed.

2278 j

t O J

  • 7906140s?5 6

-.