Forwards IE Insp Rept 50-407/79-01 on 790123-26 & Notice of Violation
ML19259B753
Person / Time
Site: University of Utah
Issue date: 02/13/1979
From: Madsen G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Turley R
UTAH, UNIV. OF, SALT LAKE CITY, UT
Shared Package
ML19259B754 List:
References
NUDOCS 7903230072
Download: ML19259B753 (2)


See also: IR 05000407/1979001

Text

T

-

v.nso

UNITED STATES

.

p

o

NUCLEAR REGULATORY COMMISSION

h

[W

/o

R EGION IV

5 ..k

.

.$

611 RYAN PLAZA DRIVE, SUITE 1000

  • h

f

ARLINGTON, TEXAS 76011

\\V [

February 13, 1979

  • ses

In Reply Refer To:

Docket No. 50-407/79-01

University of Utah

Attn:

Dr. Richard Turley

Reactor Administrator

College of Engineeri.ng

Salt Lake City, Utah

84112

Gentlemen:

This refers to the inspection conducted by Messrs. M. W. Dickerson and

G. H. Verduzco of this office during the period January 23-26, 1979, of

activities authorized by NRC Operating License R-126, and to a discussion

of the findings with members of your staff at the conclusion of the

inspection.

Areas examined during this inspection are described in our report, which

is enclosed with this letter. Within these areas, the inspection con-

sisted of selective examination of procedures and representative records,

interviews with personnel, and observations by the inspectors.

During this inspection it was found that certain of your activities were

not conducted in full compliance with NRC requirements, as set forth in

the Notice of Violation enclosed herewith as Enclosure (1). This notice

is sent to you pursuant to the provisions of Section 2.201 of the NRC's

" Rules of Practice," Part 2, Title 10, Code of Federal Regulations.

Section 2.201 requires you to submit to this office, within 20 days of

your receipt of this notice, a written statement or explanation in reply

including:

(1) corrective steps which have been taken by you, and the

results achieved; (2) corrective steps which will be taken to avoid further

noncompliance; and (3) the date when full compliance will be achieved.

However, since corrective action was completed during the inspection, no

response to i.he Notice of Violation is required.

In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2,

Title 10, Code of Federal Regulations, a copy of this letter and the

enclosed inspection report will be placed in the NRC's Public Document

Room.

If this report contains any information that you or your contractors

believe to be proprietary, it is necessary that you make a written appli-

cation within 20 days to this office to withhold such information from

public disclosure. Any such application must include a full statement of

the reasons on the basis of which it is claimed that the information is

7 9 0 3 2 3 0 0~71

.

University of Utah

-2-

February 13, 1979

proprietary, and should be prepared so that proprietary information

identified in the application is contained in a separate part of the

document.

If we do not hear from you in this regard within the specified

period, the report will be placed in the Public Document Room.

Should you have any questions concerning this inspection, we will be pleased

to discuss them with you.

Sincerely,

6

G. L. Madsen, Chief

Reactor Operations and

Nuclear Support Branch

Enclosures:

1.

Notice of Violation

2.

IE Inspection Report No. 50-407/79-01