05000318/LER-1978-042-03, /03L-0 on 781212:number of Operable Charging Pumps Reduced to One Less than Number Required by Tech Specs. Caused by Packings of 2 Charging Pumps Reaching Their Natural End of Life Simultaneously

From kanterella
(Redirected from ML19259A748)
Jump to navigation Jump to search
/03L-0 on 781212:number of Operable Charging Pumps Reduced to One Less than Number Required by Tech Specs. Caused by Packings of 2 Charging Pumps Reaching Their Natural End of Life Simultaneously
ML19259A748
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 01/04/1979
From: Davis S, Romney K
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19259A745 List:
References
LER-78-042-03L-01, LER-78-42-3L-1, NUDOCS 7901100257
Download: ML19259A748 (1)


LER-1978-042, /03L-0 on 781212:number of Operable Charging Pumps Reduced to One Less than Number Required by Tech Specs. Caused by Packings of 2 Charging Pumps Reaching Their Natural End of Life Simultaneously
Event date:
Report date:
3181978042R03 - NRC Website

text

-

LICENSEE EVENT REPORT

- Or CONTROL B LOCK:

l l

l l

l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6

fiiTT11 Mi 01 C Cl Nl 2l@l 0l 01 -l 0l 0l 0l 0l 0l -l 0l 0l@l 4l 1l ll 1l 1l@l l@

7 8 9 LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE 30 57 CAT 58 CON'T M

S URE lL l@l0 l5 l0 l0 l0 l3 l1 l8 l@l1 l2 l1 l217 8 )@ 0l 1 01 41 7 9l@

7 8

60 61 DOCKET NUMB ER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h 10 l 2 l At 0741 22 charging pump was discovered to have excessive primary packing I

o 3 l leakage (21 charging pump had been previously isolated for packing leakage),

i l reducing the number of operable charging pumps to one less than the number i

o 4

rg pg] i required by T.S. 3.1.2.4.

22 charging pump was returned to service at 1330.

l #23 charging pump remained operable during the 6 vent. LER 77-69 describes o

s io;2; ; a similar event.

l l 0 l8 l l l

E CO E S BC E COMPONENT CODE SU8 CODE SU E

g P lC l@ l E @ l Fl@

XlXlXlX XlXl@

Z [@ l Z @

7 8

9 10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION I

l 1

g l 0';3 lTl l_l F

WT1

@jUb I

IW I-l I

_ 21 22 23 24 26 27 N

M 30 31 32 KN AC ON O P teT M

HOURS 22 S8 1 FOR B.

SUPPL 1 MANUF C RER B l@l Z l@

l Z l@

Zl@

l0l0l0lu

[ N_J @

[Y_j@

Al@

Xl9l9l9l@

33 34 35 36 37 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h I This event was caused by the packinos (UTEX INDUSTRIES #0722-04-0194-19) of I

i O

li li i i two charaina pumps reachina their natural end of life simultaneously.

FCRs I

i 2 1 77-0124 and 78-0101 are currently in proaress to facilitate packina repairs I

I and allow extended packina service life respectively.

I i

3 FTTTIl l

"^'2SY

% POWER OTHER STATUS DIS O R DISCOVERY DESCRIPTION ST l__E_l@ l 0 l 9 l 7 l@l

- NA l

lAl@l Operator Observation l

i s

' A!TiviTY COMTeNT OF RELE ASE AMOUNT OF ACTIVITY LOCATION OF RELEASE RELEASE @D LZj@[

NA l

l NA l

Lz_l i

e

,ERSO~~EL ExPOSsES NUVBE R TYPE

DESCRIPTION

y l 0l 01 Ol@Lzj@l NA l

,ERSONNEl'i~;uWiES DESCRiPTiO~@

NUMBER L2_Lajl010101@l NA l

7 8 9 11 12 80

?#E '"^"'AiON '' " @

ESCn

@l NA l

1 9 7

8 9 10 80 PUBLIC TY NRC USE ONLY NA l

l 1 l l l l l l l l l ll d d@l 790l'10g9{ngg T

S. M. Davis /K. M. Romney 4WN psons: