05000318/LER-1979-051-03, /03L-0:on 791228,while Taking Log Readings, Operator Discovered Failure of Containment Gaseous Monitor. Caused by Loose Monitor Detector Cable Connector,Probably Left Unsecured After Recent Surveillance Test

From kanterella
(Redirected from ML19257C761)
Jump to navigation Jump to search
/03L-0:on 791228,while Taking Log Readings, Operator Discovered Failure of Containment Gaseous Monitor. Caused by Loose Monitor Detector Cable Connector,Probably Left Unsecured After Recent Surveillance Test
ML19257C761
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 01/25/1980
From: Davis S, Rizzo P
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19257C759 List:
References
LER-79-051-03L-01, LER-79-51-3L-1, NUDOCS 8001300312
Download: ML19257C761 (2)


LER-1979-051, /03L-0:on 791228,while Taking Log Readings, Operator Discovered Failure of Containment Gaseous Monitor. Caused by Loose Monitor Detector Cable Connector,Probably Left Unsecured After Recent Surveillance Test
Event date:
Report date:
3181979051R03 - NRC Website

text

NRC F ORM 366 U. S. NUCLEAR REGUL ATONY COMMISSION (7 77)

LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6

MIoIcIcINI2l@l0l0 -1010101010l-1010l@l4Il 11111 @l l@

0 i 7

8 5 LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE JO 57 CAT b8 CON'T 10111 3$"c' d l015 0101013Il18l@l1l2 21817 l 9 l@l 0 l 1 l 2 l S I 8 l 0 @

?

8 60 61 DOCKET NUM8ER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROB ABLE CONSEQUENCES h 1012I At 0900 while takinc_ his log readings, an operator discovered the contairinent l0 lal gaseous monitor had failed. The monitor was placed out of service in accord-I

Ol4l l snce with T.S. 3.4.6.1.

The containment air particulate monitor and the I

1015 I I containment sump level alarm remained operable during the event. The contain-I I ment gaseous monitor was returned to service at 1450 on 12/31/79. This is i

O e O

7 not a repetitive occurrence.

m _ _

O 8

t "O3 80 7

8 9

~ '

DE CO E

$UBC E COMPONENT CODE SUBCOdE SU DE O 9 lM Cl@ (_A1@ Lc_J@ l 11 NI Sl Tl Rl Ul@ l_XJ@ LZ_j @

7 8

9 to 11 12 13 18 19 20 SEQUENTI AL OCCURRENCE REPORT REV:SION LE R/RO EVENT YE AR REPORT NO.

CODE TYPE N O.

@ Nug 17 19 I l-1 10 51 11 l_/_]

lo 13 I L l l---J l 01 "e

21 22 23 24 26 27 28 29 30 31 32 AK N AC ONP NT MT HOURS 22 S B 1 D

FOR 8.

SUPPLIER

  • MANUFACTURER H l@[_Z_J@

[Z_j@

IZl@

1010 0 ul

[.Y J @

LNj@

[ A__j@

IW 11 1210 l@

33 34 35 36 37 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h i

O l The containment caseous monitor detector cable connector was found to be li li i i loose, causing a loss of sianal. The connector is of a detented twist-lock I

i 2 l variety which may have been inadvertently lef t unsecured.af ter comnletion 1

i 3 I of a recently scheduled surveillance test, allowino it to loosen af ter some f

I time.

I i 4 7

8 9 80 ST

% POWER OTHERSTATUS DIS Y

DISCOVERY DESCRIPTION Li ]5J l EJ@

ll Q Q@l NA l

lBl@l Operator Observation l

~

' A!TiviTY CSTENT O

RELEASED OF RELEASE AMOUNT OF ACTIVITY

,LOCATIO1 CORTL{ASE q

[_z] @ l.Z.J@SES NA l

l NA IOJV (J 't c l

l i s

,ERSO~~EL EoOS NUMBER TYPE

DESCRIPTION

IOlOlOl@[Z_j@l NA

~

1 7 PERSONNEL INJURIES OESCRi,uON@

NUM.ER 101 Ol Ol@l NA I

i a n

7 8 9 11 12 80

'g5 o' og^"R #O,f '^""" @

80013 o o

^'

E bN l

[_Z_j@l NA 1 9 7

8 9 10 80 d@ DESCRIPTION tss l

NA -

1 Ifililllillli?2 2 O

,80,3.. j; 7

8 9 10 68 69 S. H. Davis /P. G. Rizzo (301)234-7942nqu -

Ed NAME OF PREPARER pnoye:

LER NO.

79-51/3L DOCKET NO.

50-318 EVENT DATE 12/28/79 REPORT DATE 01/25/80 ATTACHMENT CAUSE DESCRIPTION AND CORRECTIVE ACTIONS _:

(CONTINUED)

Technicians involved in radiation monitoring system maintenance have been cautioned to insure connectors in the system are securely detented when they are rejoined after maintenance.