ML19257C480

From kanterella
Jump to navigation Jump to search
Forwards LERs 80-008/01T-0 & 80-010/01T-0
Date released: 09/28/2019 Download: ML19257C480


LER 80-010/01T-0:on 800111,during Review for IE Bulletin 79-14,S&W Found Stress on Vertical Rod Hangers SW-H-162A & SW-H-160A to Be Over Design Allowable.Caused by Incorrect Valve Weights Used in Pipe Support Design Calculations
ML19257C492
Person / Time
Site: North Anna Dominion icon.png
Issue date: 01/24/1980
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19257C492 (2)
LER 80-008/01T-0:on 800111,during Review for IE Circular 78-08,S&W Found Control Room Air Conditioning Chiller Units Control Panel Not Qualified to Seismic Category I Requirements.Cause Unknown.Vendor Reviewing Components
ML19257C491
Person / Time
Site: North Anna Dominion icon.png
Issue date: 01/24/1980
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19257C491 (2)
Forwards LERs 80-008/01T-0 & 80-010/01T-0
ML19257C479
Person / Time
Site: North Anna Dominion icon.png
Issue date: 01/25/1980
From: Stallings C
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19257C479 (1)