,e UNITED STATES pa asc oq%
NUCLEAR REGULAT ORY COMMISSION y%
REGloN IV y
o I
611 RYAN PL AZA D RIVE, SulTE 1000 O
'I[
ARLINGTON, TEXAS 76012 o,
c 30 OCT B73 J
Docket No.
99900391/79-01 Marotta Scientific Controls, Inc.
ATTN:
J. G. Kenann President & Chief Executive Officer Boonton Avenue Boonton, New Jersey 07005 Gentlemen:
This refers to the QA Program inspection conducted by Mr. Um. D. idley of this office on October 1-5, 1979, of your facility t Boonton, New Jersey associated with the manufacture of ASME "N" Class 1, 2, and 3 valves and to the discussions of our findings with you and members of your staff at the conclusion of the inspection.
This inspection was made to confirm that, in the areas inspected, your QA Program is being ef fectively implemented. The inspection effort is not designed to assure that unique quality requirements imposed by a customer are being imple=ented; nor to assure that a specific product, co=ponent or service provided by you to your customers, is of acceptable quality.
As you know, the NRC requires each of its licensees to assume full responsibility for the quality of specific products, co=ponents or services procured from others.
You should therefore not conclud2 that the NRC's inspection exempts you from inspections by an NRC licensee or his agents nor from taking effective cor-rective action in response to their findings.
Areas examined and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and c.bservations by the inspector.
During the inspection it was found that the implementation of your QA Program failed to meet certain NRC require =ents.
However the specific finding was corrected, and appropriate action to prevent recurrence was implemented prior to the termination of the inspection.
In accordance with Section 2.790 of the Co= mission's " Rules of Practice,"
Part 2, Title 10, Code of Federal Regulations, a copy of this letter with the enclosure, together with the enclosed inspection report, will be placed in the Commission's Public Document Room.
If this report contains any 1687 053 so o t o40 3N
Harotta Scientific Controls, Inc.
2 information that you believe to be proprietary, it is necessary that you make a written application within thirty (30) days to this office to withhold such information from public disclosure.
Any such application must include a full state =ent of the reasons on the basis of which it is claimed that the informa-tion is proprietary, and should be prepared so that proprietary information identified in the application is contained in a separate part of the documect.
If we do not hear froa you in this regard within the specified period, the report will be placed in the Public Document Room.
Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely, GOl Uldis Potspovs, Chief Vendor Inspection Branch