Telephone 617 366-90ll TWE F50 390 0739 YANKEE ATOMIC ELECTRIC COMPANY n.s.2.1

.m, WYR 79-161 20 Turnpike Road Westborough, Massachusetts 01581

.Ya_n n',

uxse December 21, 1979 United States Nuclear Regulatory Commission Washington, D. C.

20555 Attention: Office of Nuclear Reactor Regulation Mr. D. L. Ziemann, Chief Operating Reactors Branch #2

References:

(A) License No. DPR-3 (Docket No. 50-29)

(B) USNRC Letter to Yankee Rowe dated September 12, 1979 (C) YAEC Letter to US!BC dated July 18, 1975 (D) YAEC Letter to USNRC dated November 2, 1977 (E) YAEC Letter to USNRC dated November 7, 1979 (F) YAEC Letter to US!BC dated December 7, 1979

Dear Sir:

Subject:

Water Hammer Reference (E) was submitted in response to your letter reference (B) regarding steam generator water hammer. We wish to reiterate that we do not have steam generator water hammer at Yankee Rowe.

The tranjents described in reference (B) have been reviewed. Yankee Rowe has not experienced steam generator water hammer subsequent to modifications made in 1966.

We hope this final clarification adequately addresses your concerns.

Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY

.b D. E. Moody Manager of Operations BLD/dep 1654 334 79123106 M g