Updates 790921 Response to IE Bulletin 79-18, Audibility Problem Encountered on Evacuation of Personnel from High Noise Areas. Engineering Study Complete & Mod/Installation of Equipment to Be Completed by 800312
ML19256G304
Person / Time
Site: Crystal River 
Issue date: 12/13/1979
From: Moore G
FLORIDA POWER CORP.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
IEB-79-18, NUDOCS 7912310010
Download: ML19256G304 (2)


Text

.-

< tl

.c ei;ck];WC h s

IN D

t

?

g {.

oc h

d', r

%29#

'r

't i Florida Power CO R Po a a T so N December 13, 1979 File:

3-0-3-a-4 Mr. J. P. O'Reilly Director U.S. Nuclear Regulatory Commission Office of Inspection and Enforcement Suite 3100 101 Marietta Street Atlanta, GA 30303

Subject:

Crystal River Unit 3 Docket No. 50-302 Operating License No. DPR-72 IE Bulletin 79-18 Audibility - High Noise Areas

Dear Mr. O'Reilly:

In our previous response to you, dated September 21, 1979, concerning Item 2 of the subject bulletin, we stated that an Engineering Study was being conducted and that a schedule for modification / installation of equipment could be determined upon its completion.

The Engineering Study has been completed and the modification /

installation of equipment, which includes the visual indicators for the identified very high noise areas, can be completed by March 12, 1980.

This schedule includes engineering, purchasing of materials, and installation of all equipment.

Since Item 4 of NRC Bulletin 79-18 states that all corrective actions must be completed within 120 days of the Bulletin, which would be December 5,

1979, it is necessary for us to implement temporary administrative procedures until the modifications can be completed.

We have posted a guard at the doorway of the Auxiliary Building and require everyone to sign in and out of the building in the Auxilary Bu_ilding Access Log Book.

Should the alarm annunciate, it is the guard's duty to check the Auxiliary Building Access Log Book to assure that the building has been evacuated.

If the log book indicates someone is still in the building, the guard will notify the ChemRad Section, who in turn will orgac. ate search for the missing individual (s).J a. c\\ General Office 3201 inirty fourtn street soutn. P O Box 14042, St Petersburg. Flonda 33733 e 813-866-5151 79123100( O

Mr. J. P. O'Reilly Page Two December 13, 1979 Please contact this office if you require additional information con-cerning our tempora ry administrative procedure or our schedule for modification / installation of equipment. Very truly yours, FLORIDA POWER CORPORATION l ff k}/hnL ,'G. C. Moore Assistant Vice President Power Production JAHemhT05(D5) cc: Director Division of Operating Reactors Office of Inspection and Enforcement U.S. Nuclear Regulatory Commisgion Washington, D.C. 20555 1660 218 e}}