Forwards LERs 79-057/03L-0 & 79-058/03L-0
Date released: 09/27/2019 Download: ML19256G012


LER 79-058/03L-0:on 791121,boron Injection Tank Declared Inoperable Due to Low Concentration.Caused by Inadvertent Safety Injection.Concentration Increased by Batching
ML19256G018
Person / Time
Site: Farley 
Issue date: 12/19/1979
From: Hairston W
ALABAMA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19256G018 (1)
LER 79-057/03L-0:on 791122,steam Generator B Level Channel 486 Declared Inoperable Due to High Reading.Caused by Instruments Equalizing Valve Leaking.Valve Tightened,Tested & Returned to Operation
ML19256G016
Person / Time
Site: Farley 
Issue date: 12/19/1979
From: Hairston W
ALABAMA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19256G016 (1)
Forwards LERs 79-057/03L-0 & 79-058/03L-0
ML19256G011
Person / Time
Site: Farley 
Issue date: 12/19/1979
From: Clayton F
ALABAMA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References