ML19256F681

From kanterella
Jump to navigation Jump to search
Forwards IE Bulletin 79-28, Possible Malfunction of Namco Model EA180 Limit Switches at Elevated Temps. Action Required
ML19256F681
Person / Time
Site: Grand Gulf  
Issue date: 12/07/1979
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Stampley N
MISSISSIPPI POWER & LIGHT CO.
References
NUDOCS 7912200049
Download: ML19256F681 (2)


Text

C

/

'o UNITED STATES

~,,

8 NUCLEAR REGULATORY COMMISSION 3E E

REGION 11 n

{ g Mh.g#

c, 101 MAFtIETT A ST., N.W., SUITE 3100 o

ATLANTA, GEORGIA 30303 DEC 7 1979 In Reply Refer To:

)RI lEQ_

c_50-416, 50-417)

Mississippi Power and Light Company Attn:

N. L. Stampley Vice President of Production P. O. Box 1640 Jackson, Mississippi 39205 Gentlemen:

Enclosed is IE Bulletin No. 79-28 which requires action by you with regard to your power reactor facility (ies) with an operating license or a construction permit.

Should you have questions regarding this Bulletin or the actio.ns required of you, please contact this office.

Sincerely, m.. / ~

James P. O'Reilly Director

Enclosures:

1.

IE Bulletin No. 79-28 w/its Attachment 2.

List of Recently Issued 1E Bulletins 182$

Is7 7912200 0 4 7

DEC 71979 f

Mississippi Power and Light Company -

cc w/ encl:

C. K. McCoy Plant Manager Post Office Box 756 Port Gibson, Mississippi 39150 m

182gi8

~

UNITED STATES SSINS No.: 6820 NUCLEAR REGULATORY COMMISSION Accession No.-

0FFICE OF INSPECTION AND ENFORCEMENT 7910250505 WASHINGTON, D.C.

20555 December 7, 1979 IE Bulletin No. 79-28 POSSIBLE MALFUNCTION OF NAMCO MODEL EA180 LIMIT SWITCHES AT ELEVATED TEMPERATURES Description of Circumstances:

The NRC has been recently advised through a 10 CFR 21 report from Namco Controls that a malfunction of a Namco Model EA180 stem mounted limit switch (SMLa) occurred at the Cooper Nuclear Statien.

Investigation into thc switch failure by the licensee revealed yellow and orown " crystal-like" tesin deposits on the internal components of the switch. The affected switch is located inside the drywell containment at this facility and was being used as the replacement switch for an unqualified SMLS previously identified in IE Bulletin Nos.

78-04 and 79-01.

According to the manufacturer, the problem was traced to a batch of top cover gaskets of which some were over-impregnated and insuf ficiently heat cured.

It has been determined that this condition can leave an uncured residue of " Loctite" in the gasket, which vaporizes at sustained temperatures above 175 F.

To correct the problem, the manufacturer has revised production techniques beginning September 1979 in order to better control the impregnation process and to properly heat cure the gaskets following impregnation.

This problem is unique to all Namco Model EA180 series switches received by licensees after March 1, 1979. According to the manufacturer, the suspect switches can be identified by checking the date code which is a 4 digit number stamped on the conduit boss of the switch housing.

Namco recommends that any EA180 series switch with a date code between 02-79 through 08-79 should have its top cover gasket replaced.

Also, licensees should request from their suppliers of equipment on which Namco EA180 series switches are used that they check their inventory and replace top cover gaskets on switches date coded between 02-79 through 08-79.

The enclosed letter from Namco further describes the high-temperature environ-mental problem with the top cover gaskets used in their EA180 switches and provides recommendations to correct the problem. According to Namco, this letter has been sent to each customer who was shipped EA180 switches between February 21, 1979, and August 24, 1979.

Action to be Taken by Licensees of Powe Holders of Construction Permits:

1.

Determine if your facility has inst DUPLICATE DOCUMENT switches in any safety-related equi containment, including valve positi Entire document previously containment isolation valves.

entered into system under:

ANO k

)

No. of pages:

i