ML19256E540
| ML19256E540 | |
| Person / Time | |
|---|---|
| Site: | Browns Ferry |
| Issue date: | 10/25/1979 |
| From: | Ippolito T Office of Nuclear Reactor Regulation |
| To: | Parris H TENNESSEE VALLEY AUTHORITY |
| References | |
| NUDOCS 7911080008 | |
| Download: ML19256E540 (3) | |
Text
30~ eof /*b /P
.s, g
UNITED STATES
+
e 3 g NUCLEAR REGULATORY COMMISSION p.
WASHINGTON, D. C. 20555
%Q.,OR,/
October 25, 1979 Docket Nos. 50-259 50-260 and 50-296 Mr. Hugh G. Parris Manager of Power Tennessee Valley Authorit.
500 A Chestnut Street, Tower II Chattanooga, Tennessee 37401
Dear Mr. Parris:
Reference is made to your submittals of December 21, 1978, March 1, 1979 and June 12, 1979 on the containment purge and venting systems at the Browns Ferry Nuclear Plant, Units Nos.1, 2 and 3.
To assist us in our review, we request the information identified in the enclosure.
Please provide the requested infomation within 60 days of receipt of this letter.
Sincerely, h
w Thom ppolito, Chief Operating Reactors Branch #3 Division of Operating Reactors
Enclosure:
Request for Additional Information cc w/ enclosure:
See next page h
1294 012 7 9110 8 0 C 5'
,L a
Mr. Hugh G. Parris Tennessee Valley Authority 2-
=c:
H. S. Sanger, Jr., Esquire General Counsel Tennessee VLlley Authority 400 Commerce Avenue E 11B 33 C Knoxville, Ter.nessee 37902 Mr. Dennis McCloud Tennessee Valley Authority 400 Chestnut Street. Tower II Chattanooga, Tennessee 37401 Mr. E. G. Beasley Tennessee Valley Authority 400 Commerce Avenue W 10C 131C Knoxville, Tersnessee 37902 Robert F. Sullivan U. S. Nuclear Regulatory Commission P. O. Box 1863 Decatur, Alabama 35602 Athens Public Library South and Forrest Athens, Alabama 35611 1294 013
BROWNS FERRY NU"I. EAR PLANT UNITS NOS. 1, i and 3 REQUEST FOR ADDITIONAL INFORMATION CONTAINMENT PURGE AND VENTING SYSTEMS DOCKET NOS. 50-259, :i0-260 AND 50-296 1.
With regard to the containment purge and vent system, discu.ss the provisions made to ensure that your system has been designed in accordance with each paragraoh and sub-paragraph of Branch Technical Position CSB 6-4.
1294 014