Supplements 780814 Response to IE Bulletin 78-10, Bergen-Paterson Hydraulic Shock Suppressor Accumulator Spring Coils. Corrective Action Completed.Forwards Discussion of Corrective Action Results
ML19256E398
Person / Time
Site: Browns Ferry  
Issue date: 10/23/1979
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NUDOCS 7911050134
Download: ML19256E398 (4)


Text

,

a

/

TENNESSEE VALLEY AUTHORITY ':!;','.,

.. /, '"

CH ATTANOOG A. TENr ESSEE 37401 e

400 Chestnut Street Tower II

'(

O y,yq October 23, 1979 Mr. James P. O'Reilly, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Region II - Suite 3100 101 Marietta Street Atlanta, Georgia 30303

Dear Mr. O'Reilly:

OFFICE OF INSPECTION AND ENFORCEMENT BULLETIN 78 RII:JP0 50-259, -260, -296 - BROWNS FERRY NUCLEAR FLANT The corrective action which was taken as a result of the subject bulletin (described in TVA's response to Bulletin 78-10 dated August 10, 1978, J. E. Gilleland to J. P. O'Reilly) has been completed. Enclosed for your information are the results of those corrective actions.

Very truly yours, TENNESSEE VALLEY AUTHORITY

~,l M,h

.(,f L 'M.

11s, ager Nuclear Regula on and Safety Enclosure cc: Office of Inspection Enforcement (Enclosure)

,'f

. Division'of Reactor' Operations, Inspection

,y U.S. Nuclear f.egulatory Commission Washington, DC 20555 4

4 e

i C 284 7b/3, 134 %T 7 9110 5 0-g An Equal Opportunity Employer

o ENCLOSURE In a TVA letter from J. E. Gilleland to J. P. O'Reilly, of NRC dated August 14, 1978, TVA's approach in complying with the requirements of the subject bulletin for Browns Ferry Nuclear Plant is outlined.

Refueling outages for the three units have now been completed. Bergen-Paterson snubbers of external pipe configuration were subject to inspection under the following conditions:

1.

Serial (lot) numbers were within the suspect range.

, 2.

Lot numbers were not legible.

3.

Lot number tags were not attached.

j $

The results of our investigation are shown in the attached table and summarized as follows:

Investigation of unit 3 snubbers dur ng the September 1978 refueling d

outage revealed no snubbers to have lot numbers in the range of interest.

However, three spare snubbers in the storeroom did have lot numbers in this range. All three accumulator springs were rusty and one was broken.

All springs were replaced.

Thirty-one snubbers were removed from unit 1 during the December 1978 refueling outage for accumulator spring verification.

Before disassembly all snubbers were functionally tested and all met the operability requirement. During the outage, some snubbers were not disassembled because of time limitations. However, they were identified and subsequently disassembled for spring inspection. Twenty-nine snubbers contained petro-chemical-coated type accumulator springs.

One spring was in good condition; all the rest were rusty.

Twenty-one of these springs were also broken. Two snubbers contained teflon-coated accumulator springs.

Oae spring was in good condition and org had some rust spots.

Three snubbers were removed from unit 2 during the April 1979 refueling outage to check accumulator spring condition.

One snubber contained a petro-chemical-coated spring which was rusty and broken. The other two snubbers contained teflon-coated sprPags which were in good condition.

In total, 37 snubbers were examined and 23 had broken accumulator spri.ugs.

All snubbers were functionally tested before being disassembled; all met the functional test acceptance criteria.

O 1?:'

?85

ATTACHMENT

.h ',

e,

~'

c BERGEN-PATERSON ACCUMULATOR SPRING INSPECTION DETAILS ~

y Snubber System Number Iot Number Size Spring Coating Spring Condition Corrective Action Unit 3 - September 1978 - No Snubbers Within Subject Lots Storeroom - September 1978 4

Storeroom NA Missing HSSA 10 Petro-Chemical Rusty Installed teflon-coated spring

.NA F 62955 HSSA 10 Petro-Chemical Rusty & brokan Installed teilon-coated spring NA F 62955 HSSA 10 Petro-Chemical Rusty Installed teflon-coated spring Unit 1 - December 1978 Main Steam SSA1 Obliterated HSSA 20 Petro-Chemical Rusty Installed spare snubber SSB2 Obliterated liSSA 30 Petro-Chemical Rusty & broken Installed spare snubber SSB4 F 61284 HSSA 10 Petro-Chemical Rusty Installed spare snubber

-SSB5 Missing HSSA 10 Petro-Chemical Rusty & broken Installed spare snubber SSC1 F 61284 HSSA 30 Petro-Chemical Rusty & broken Installed teflon-cor,ted spring SSC2 F 61264 HSSA 30 Petro-Chemical Rusty & broken Installed teflon-coated spring SSC4 F 61284 HSSA 10 Petro-Chemical Rusty & broken Installed spare snubber Feedwater SSAI Missing HSSA 10 Petro-Chemical Rusty & broken Installed spare snubber -

SSAZ F 62955 HSSA 10 Petro-Chemical Rusty Installed teflon-coated spring SSA4

, F 61284 HSSA 10 Petro-Chemical Rusty & broken Installed spare snubber SSAS

'F 61284 HSSA 10 Petro-Chemical Rusty & broken installed spare snubber SSA6 Missing HSSA 10 Petro-Chemical Rusty Installed spare snubber SSA7 F 62955 HSSA 10 Petro-Chemical Rusty & broken Installed spare snubber SSA8 F 61284 HSSA 10 Petro-Chemical Rusty & broken Installed spare snubber SSA9 Obliterated HSSA 10 Petro-Chemical Rusty & broken Installed spare snubber SSBl F 61284 I!SSA 10 Petro-Chemical Rusty & broken Installed spare snubber SSB2 Missing IISSA 10 Petro-Chemical Rusty & broken Installed spare snubber

--+

NJ SSB3 F 61284 IISSA 10 Petro-Chemical Rusty & broken Installed teflon-coated spring SS B4 F 61284 HSSA 10 Petro 3 Chemical Rusty & broken Installed spare snubber l

SSB5 Missing liSSA 10 Petro-Chemical Rusty Installed teflon-coated spring SSB6 Missing HSSA 10 Petro-Chemical Rusty & broken Installed spa re snubber SSB8 Missing IISSA 10 Petro-Chemical Rusty & broken Installed stainless-steel spring C%?

c)w SSB9 F 61284 HSSA 10 Petro-Chemical Rusty & broken Installed spare snubber

,i

~ '

3 i

e

z.,

BERGEN-PATERSON ACCUMULATOR SPRING INSPECTION DETAILS s

(continued) f 4

Snubber j

j System Number Lot Number Size Spring Coating Spring Condition Corrective Action 3

5 Core Spray R-2 F 62955 HSSA 10 Petro-Chemical Rusty & broken

,' -Installed spare snubber R-6 North F 62955 HSSA 10 Petro-Chemical

-Rusty

' Installed teflon-coated spring

]

R-8 F 62955 HSSA 10 Petro-Chemical Rusty & broken Installed spare snubber 4

R-9 F 62955 HSSA 10 Petro-Chemical Rusty & broken Installed spare snubber

.R-13 North F 62955 HSSA 10 Petro-Chemical Good Installed spare snubber R-13 South F-62955 HSSA 10 Petro-Chemical Rusty Installed spare snubber 3

RCIC R-7 Lower Obliterated HSSA 3 Teflon Good Installed spare snubber

(

5 PSC SS12 Missing HSSA 10 Teflon Rusty Installed teflon-coated spring l

t i

Unit 2 - April 1979

{

t PSC SS7AX F 61284 HSSA-10 Petro-Chemical Rusty & broken Installed spare snubber j

s RCIC R-7 Lower Obliterated HSSA-3 Teflon Good Reinstalled snubber R-5 East Obliterated HSSA-3 Teflon Good Reinstalled snubber 4

3 4

?

?

34 s

E i

_m

'V 4

e, 8

.4 PJ CO t