ML19256E325
| ML19256E325 | |
| Person / Time | |
|---|---|
| Site: | Skagit |
| Issue date: | 10/03/1979 |
| From: | Black R NRC OFFICE OF THE EXECUTIVE LEGAL DIRECTOR (OELD) |
| To: | Deale V, Hooper F, Linenberger G Atomic Safety and Licensing Board Panel |
| Shared Package | |
| ML19256E326 | List: |
| References | |
| NUDOCS 7911020102 | |
| Download: ML19256E325 (61) | |
Text
-
- c.. x C PUBLIC DOCUMENT ROOM
/
UNITED STATES
//-
O[
~
NUCLEAR REGULATORY COMMISSION 2
9 o
3
- ,E WASHINGTON, D. C. 20555
%...../
g e
October 3, 1979 a
Valentine B. Deale, Esq., Chairman Dr. Frank F. Hooper Atomic Safety and Licensing Board School of Natural Resources 1001 Connecti:ut Avenue, N.W.
University of Michigan Washington, DC 20036 Ann Arbor, MI 48109 Mr. Gustave A. Linenberger Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Washington, DC 20555 In the Matter of Puget Sound Power & Light Company,~et al.
(Skagit Nuclear Power Project, Units 1 and 2) ~~ -
Docket Nos. STN 50-522 and STN 50-523 Gentlemen:
Enclosed is the NRC Staff's geology, seismology and geotechnical engineering review report which will be incorporated as Section 2.5 of the Final Supple-ment to the Staff's Safety Evaluation Report (SER). This report will also constitute the Staff's direct testimony on geology-seismology issues in this proceeding. The Staff's witnesses will consist of H. Lefevre, S. Wastler, Dr. J. Kelleher, and Dr. R. Regan. Also enclosed is the supplemental testi-many of Dr. Kelleher which addresses the Board request for testimony concerning the methods used by the Staff to estimate strong ground motion.
The U.S. Geological Survey has assisted the NRC Staff in the review of the Skagit site. The U.S.G.S.'s review reports of February 23, 1978 and Sep-tember 17, 1979 (these reports have been previously distributed to the Board and parties), are attached as Appendix D to the Staff's report.
U.S.3.S.
personnel who assisted in the Skagit review will be made available as wit-nesses.
I will submit a list of U.S.G.S. witnesses at a later date.
Sincerely, Richard L. Black Counsel for NRC Staff
Enclosures:
As stated cc w/encls: Servic.e List 1258 284 7911020/ O (
s-SAFETY EVALUATION REPORT INPUT - GEOSCIENCES BRANCH 2.5 Geology, Seismolooy and Geotechnical Engineering Introduction and Summary The Nuclear Regulatory Commission staff has completed its review of the geological, seismological, and geotechnical aspects of the proposed Skagit Nuclear Power Project, Units 1 and 2, and concludes that there are no geologic, seismologic, or geotechnical considerations that would make the site unsuitable for the proposed units.
Our review included consultation with Dr. John Kelleher, a former staff seismologist, now associated with Woodward-Clyde Consultants and Dr. Robert Regan, a geophysicist with the Phoenix Corporation.
Dr. Kelleher N rformed the seismology review, wnile Dr. Regan evaluated the aeromagnetic data submitted by the applicant (EDCON report).
Dr. Kelleher's Sept. 25, 1979 seismology evaluation is contained in Appendi.t E to this report and is considered a supplement to the staff March, 1978 testimony.
Dr. Regan's reports of Sept.1,1979 and Sept. 18, 1979 are contained in Appendix F to this report.
The staff's detailed geologic review of the site region considered regional faulting, the possibility of near site faulting, the teO.onic basis for earthquake design evaluation and the effects of nearby and distant volcanism on the proposed site.
No other geologic or seismic hazards have a potential for impacting the site.
The staff concludes the*. neither the faulting nor volcanism presents a hazard to the proposec Skagit nuclear facility that cannot be accomodated in the seismic design and that the seisaic design basis is conservative.
The U.S. Geological Survey, in their role as advisors to the NRC staff, has reached review conclusions with respect to potential faulting near the proposed site, volcanic hazards, :7d with respect to the appropriate reference acceleration to be used for site seismic design basis.
The U.S.
1258 285 2-1
Geological Survey's review reports of February 23, 1978 and Septe.T.ber 17, 1979 for the proposed Skagit site are contained in Appendix D to this report.
The Skagit Nuclear Power Project application has been subjected to an
~
extensive geosciences review beginning in the fall of 1974.
The staff's review (NRC and U.S. Gcc!cgical Survey) has included numerous site and vicinity visits, dis.ussions with the applicant, requests for additional information, several meetings and field trips with geologists of the Washington Division of Geology and Earth Resources, as well as a meeting and later field trip with the intervenor's Skagitonians Concerned About Nuclear Power (SCANP) ge: iogical consultant, Dr. Eric Cheney.
Several discussions were held with seismologists of the University of Washington at Seattle and Victoria.(British Columbia) Geophysical Observatory.
Geology and seismology matters were discussed at great length at the Atomic Safety Licensing Board Proceedings of July 1975, July 1976, March 1978, and March 1979.
As a result of geologic questions arising out of the March 1978 ASLB proceedings, the NRC and USGS requested, on June 9, 1978, that the applicant make additional geologic studies.
In May and June 1979 the applicant responded to our request and submitted a report entitled " Report of Geologic Investigations in 1978 and 1979.' This report has been reviewed in preparation of this report.
The proposed site is approximately 10 kilometers east-northeast of the town of Sedro Woolley, Washington, within the Northern Cascace Mountains section of the Cascade Mountains Physiographic province.
The proposed units are to be located on a glaciated bedrock bench over 90 meters above the flood plain of the Skagit River.
The tectonic setting of the proposed Skagit site region is characteristic of a remnant subducting plate margin.
The structural features of the region are not substantially different from known active subducting plate margins, though no Benioff zone is recognized.
Based on this, we have considered five potential earthquake sources for evaluating the ground motion at the site:
(1) subduction interface, (2) 1946 Vancouver Island 2-2 1258 286
i A
earthquake, (3) intraplate events, (4) the 1872 earthquake of the Pacific Northwest, and (5) earthquakes associated with the Devils Mountain fault zone (see Section 2.5.2.3).
The staff concludes, as a result of our review, that the significant earthquakes to be considered are (1) shallow earthquakes associated with possibly active near surface structures similar to the Devils Mountain fault, (2) intraplate earthquakes and (3) the 1872 earthquake of the Pacific Northwest.
The highest seismic design basis vibratory ground motion corresponaing to any of tnese postulated events is conservatively described by Regulatory Guide 1.60 spectra scaled to a reference acceleration of 0.35g at 33 Hz.
The motion is to be input at the free field finished grade.
Although the USGS reports do not agree with the tectonic distinction between the areas east and west of the Cascade volcanic chain which the staff supports, the reports agree that 0.35 g used to scale Regulatory Guide 1.60 response spectra is an adequately conservative seismic design basis for the site.
2.5.1 Geology 2.5.1.1 Regional Geology The pre-Tertiary rock of the North Cascades can be separated into three contrasting geologic zones separated by two major northerly trending post mid-Creatceous faults (Misch, 1966).
These faults are the Straight Creek Fault (See Section 2.5.1.2 of this document) on the western flank of the North Cascades and the Ross Lake Fault on the east side.
The area of concern with regard to the Skagit site is the Western Cascade Thrust zone located west of the Straight Creek Fault.
Misch's (1966) stratigraphic and structural type areas are located in the Western Cascade Thrust zone and interpreted westward.
The geology of this western zone is dominated by extensive thrust faults which flatten westward from a steep root zone that has been severed by the Straight Creek Fault (Misch, 1966).
The structurally higher Shuskan thrust (Misch,1966), places the Palezoic Shuskan Metamorphic Suite (Misch, 1966) above the mid-Devonian to mid-Perr.ian Chilliwack Group.
The Shuskan Metamorphic Suite includes the 2-3 1258 287
Shuskan greenschist and the underlying Darrington Phyllite.
The Chilliwack Group is comprised of a variety of metamorphosed rocks, for example, basaltic and andesitic volcanics, limestones, and phyllite.
The structurally lower Church Mountain thrust parallels the Shuskan thrust (Misch, 1966).
The Church Mountain thrust emplaces the Chilliwack Group over the Jurrasic to lower Cretaceous Nooksack Formation and Wells Creek Formation.
Misch (1966) points out that while these rocks are structurally the lowest rocks known in the western zone, additional thrusts could lie dseper.
Sheared zones within the Chilliwack, between and parallel to the two major thrusts represent zones of imbricate thrusting.
The age of the thrust system is bracketed by the Lower Cretaceous (less than 135 m.y.b.p.) Nooksack Formation and the Upper Cretaceous (greater than 65 m.y.b.p.) to Pal, eocene Chuckanut Formation which unconformably overlies the thrust (Misch,1966).
Tne thrusts are cut by the Straight Creek Fault and have been folded during the Eocene (Misch, 1966).
In the Skagit site area the Shuskan thrust has been mapped south of the Skagit River (approximately 6 km from the site) wrapping around the north flank of Haystack Mountain and the south flank of Cultus Mountain (Misch,1977; Miller ; in press; Puget,1979).
Whetten, et al (in press), mapping from the San Juan Islands eastward, has proposed a modification to the geology of the' Cascades as proposed by Misch (1966).
Tc the west, in the San Juan Islands, Vance (1977a) and Whetten, et al (1978) describe thrust fault bounded terranes of a generally different character and age from those recognized by Misch (1966) with the exception that the tirr-of thrusting may have been partially similar.
Whetten, et al (in press) proposes that the Mesozoic Decatur Terrane (i.e., Chilliwack Group of Misch, 1966) emplaced from the southwest by the Haystack thrust overlie the Lopez terr ine in the San Juan Islands as well as the Shuskan Metamorphic Suite in the Cascades.
In terms of the Skagit site area, Whetten would interpret Mischs' (1966) Chilliwack rocks as his Mesozoic Decatur Terrane and the Shuskan thrust in the site are (as mapped by Misch,1977; Miller, in press; Puget,1979) his southwesterly dipping Haystack thrust.
Whetten, et al (in press) proposes that the Haystack 1258 288 2,
k thrust fault is probably structurally the highest and most extensive thrust yet recognized within the family of Late Cretaceous thrust faults.
According to Whetten, et al (in press) the Haystack thrust overlies the Shuskan and Church Mountain thrusts and the crystalline core of the North Cascades.
This interpretation brackets the age of the Haystack thrust
~
between the mid-Cretaceous age for the underlying Lopez terrane in the San Juan Islands and the intrusion of the Late Cretaceous Mount Stuart Granodio-rite into t;.e Ingalls Complex.
2.E.1.2 Faulting 2.5.1.2.1 Regional Faulting The geology in the site vicinity thet has evolved during the review of the Skagit site by the NRC staff (Section 2.5.1.1) is complex.
Misch, Miller, Whetten and the applicant have been the main contributors to our present understanding of the geology.
As a result of this complexity, even with the extensive investio:stions that have been generated by the Skagit review, sufficient data is not available to determine a definitive interpretation of the site area geology.
It should be recognized that in all probability final solution to the geologic complexities of the site region will be d
years in resolving.
It should be carefully noted, therefore, that the staff has concentrated on conservatively evaluating individual aspects of the interpretations to determine their effect with regard to the safety of the proposed Skagit nuclear power plant site.
Several faults of regional extent have been reported or suggested to occur in the site vicinity:
The Shuskan and Church Mountain thrusts (Misch, 1966), the Haystack thrust (Whetten et al, in press), the Straight Creek Fault, the Devils Mountain Fault, the San Juan Islands Platform Faults and two postulated faults the "B and B" Fault (ASLB Hearing, March, 1978) and the Bellingham Bay - Lake Chaplain Fault (Cheney, 1978).
Based on the weight of the evidence, the staff concludes that the mid-Cretaceous Shuskan and Church Mountain thrust plates, the Haystack thrust, and the Straight Creek Fault are not capable.
Non capability of the Devils Mountain Fault and s
the San Juan Island Platform Faults has not been established on the basis of 1258 289 2-5
presently available data.
The existence of the two postulated faults (the "B and B" Fault and the Bellingham Bay-Lake Chaplain Fault) has not been demonstrated.
Each of these faults and the basis for the staff's conclusions will be discussed in the following paragraphs.
Shuskan and Church F.ountain Thrust The Shuksan thrust fault has an east to west displacement of approxi.eately 48 kilometers (Misch, 1966).
According to Miller (in press), the nearest mapped surface exposure of the Shuksan thrust to the site is near Talc Mountain about 8 km southeast of the proposed site.
Misch's interpretation places the western edge of the Shuksan thrust fault beneath the unconsoli-dated deposits within the Skagit valley about three to five kilometers west of the Skagit site.
The Church Mountain thrust plate underlies the Shuksan thrust picte sad has a similar amount of displacement.
The nearest extensive contact between the Church Mountain thrust plate and the under-lying Mesozoic (Lower Cretaceous and older) deposits is at the south-eastern flank of Mt. Baker, some 27 kilometers northeast of the proposed Skagit site.
Isolated, relatively small portions of the basal Church Mountain thrust fault occur 19 to 23 kilometers south of the proposed site in the vicinity of the Devils Mountain Fault.
Both thrust faults are overlain by the Chuckanut Formation which establishes the most recent movement on them as pre-Paleocene (greater than 58 m.y.b.p.) (Misch, 1967).
The overlap of the thrust plates by the Upper Cretaceous-Paleocene Chuckanut Fermation and the isolation, by erosion, of the western portion of the Shuksan-Church Mountain thrusts from the eastern portion of the thrusts in the vicinity of Mt. Baker indicates that both were part of an earlier phase of tectonic activity (PSAR) and are not capable within the
.:'ning of Appendix A to 10 CFR Part 100.
Haystack Thrust Whetten's interpretation of the Clear Lake NE quadrangle (1979) suggests that the northeasterly dipping Shuksan and Church Mountain thrusts (Misch, 1966) are overlain by the southwesterly dipping Haystack thrust.
The 2-6 1258 290
Haystack thrust fault, as shown near Haystack Mountain (Whetten, et al, 1979) is considered to be the youngest of a family of Cretaceous thrusts known to occur in the western Cascades (Wbetten et al, in press).
Whetten (in press) brackets the age of the Haystac'k Thrust as younger than the structurally lower Lopez terrane (* 100 m.y.o.) and older than the Late Cretaceous (88 m.y.o) Mount Stuart Granodiorite.
The staff concludes that the Haystack thrust is not capable within the meaning of Appendix A to lu CFh Part 100.
Straight Creek Fault The Straight Creek Fault, located 48 kilometers (km) east of the site, is a zone of discontinuous faults extending at least 210 km south from the Canadian border.
The fault continues 250 km north into British Columbia, Canada, as the Hope Fault of the Frazer Rive'r area.
Tertiary plutons interrupt the fault, along the faults total length, subdividing it into four sections.
From north to south these are the Hope Fault extending north from the Chilliwack Batholit.h, the Straight Creek fault lying between the Chilliwack and Grotto batholiths, the Evergreen Mountain segment between the Grotto and Shoqualmie batholiths, and the southern Kachess Fault segment.' The Straight Creek Fault is essentially north-south trending, with a dip ranging from 65 E to vertical.
The steep dip of the fault is reflected in the strongly linear trace of the'faelt zone.
Displacement on the Straight Creek Fault occurred in at least two episodes Late Mesozoic early Tertiary (Paleocene) and Oligocene-Miocene (Misch, 1966, Vance,1977b).
Initial displacement involved large scale right lateral strike slip movement of late Mesozoic and/or Paleocene age (Misch 1977a).
Misch (1977a) proposes 200 km of right lateral strike slip dis-placement on the Straight Creek - Frazer River Fault system based on the possible juxtaposition of contrasting metamorphic facies and terranes across the fault.
Misch also suggests that the geology west of the fault zone near Harrison. Lake in British Columbia is very similar to the geology in the Kachess Lake area, at the southern end of the fault.
Displacement on the Straight, Creek fault continued at least into the Eocene (greater 2-7 1258 291
than 36 m.y.b.p), as demonstrated by the presence of Eocene continental sedimentary rocks contained in the fault zone.
Field relations suggest that this later movement was high angle reverse faulting with the west side of the fault down dropped (Vance,~1977b).
Movement along the fault ceased by Oligocene to early Miocene time.
Tertiary plutons intrude the Straight Creek Fault and are not cut by the fault thus bracketing the age of movement along the fe91t.
Agc dating of these plut.ons give ages between 16 and 35 million years old (Vance
, 1977b).
These radiometric dates indicate continuous granitic plutonism from ear Oligocene to mid Miocene time.
Vance (1977b) and Misch (1977b, 1979) investigated the Tertiary plutons emplaced along the Straight Creek Fault and failed to find evidence of pc.st Oligocene movement.
This assumption was based on the fact that significant movement would be reflected in a distinct linear break within the pluton and in offset of the ' intrusive contacts.
Both Vance (1977b) and Misch (19775) indicate that tne f and joints found in the Tertiary plutons do not require renewed movement along the Straight Creek Fault.
More or less regular joint and fracture systems are developed in most igneous rocks, due to their origin and logically reflect post intrusive deformation (Balk,1937).
The Tertiary plutons have also been subjected to tensile stresses due to the early Pliocene arching of the Cascades which could produce similar fracture systems.
The staff does not consider these fractures to be of fault origin.
In addition, along the Kachess Fault, tne southernmost continuation of t Straight Creek Fault, late Oligocene (greater than 25 m.y.b.p.) silicic tuffs of tne Stevens Ridge type are r.ot disturbed and overlie the fault (Vance, 1977b).
A reconnaissance of the Straight Creek Fault revealed a prominent serie of linear ridges near the Straight Creek fault trace on the divide between the north fork of Diopsid Creek and Bacon Creek, near Marblemount (V 1977b).
- ance, Post glacial movement along these features is indicated (McClear and others, 1978).
Investigations indicate that these anti-slope features are most likely due to gravity, even though a tectonic origin cannot be 2-8 1258 292
e L
entirely ruled out (McCleary, and others, 1978).
Based on the available geologic data, the s i:7 cu vludes that the Straight Creek fault is non-c capable within the meaning of 10 CFR Part.100.
Even if, at a later date, the Straight Creek Fault is proved to be capable, it does not constitute a hazard to the proposed site because of its distance from the site (approximately 48 km).
Davi, Heuntain Fault The Devils Mountain fault zone is approximately 21 kilometers southwest of the proposed Skagit site at its closest approach.
It strikes about N85 W, and dips at a high angle down to the south.
Lovseth (1975) placed the length of the Devils Mountain fault zone at 24 kilometers including an inferred 11 kilometers eastward projection.
If projected 1arther to the east the fault zone would extend through Lake Cavt.aaugh into the alluviated-glaciatea valley of the North Fork of the Stilligaumish River near Boulcer Creek and perhaps farther to the n uthea t.
If projected westward the fault would extend into the alluvial sediments south of Mt. Vernon (Huntting, et al.,1961) and into Rosario Strait southeast of Lopez Island (USGS, 1977).
This fault zone was investigated axtensively by the applicant.
Studies included photoimagery i.3teraretation, geologic mapping, trenching, geophysical investigations, subsurfa e exploration and radiometric dating.
Photoimagery studies revealed no offset of the unconsolidated Pleistocene-Holocene deposits over the fault zone either in the valley of the North Fork of the Stilligaumish or the valley of the Skagit.
Interpretations by Lovst th (1975) indicate Oligocene (greater than 25 m.y.b.p.) units are the youngest consolidated rocks cut by the fault zone.
Pleistocene sediments in excess of 35,000 years old have been shown by the applicant's studies to r.ver the southern segment of the fault zone and are not offset by t.
Lovseth (1975) also found non-offset Pleistocene sediments overlying the fault during field mapping.
The applicant presented radiocarbon dating which yielded an age in excess of 35,000 years since last movement of this segment of the fault zone, wnich is considered by the applicant to demon-strate that the Devils Mountain fault zone is not capable within the meaning of Appendix A to 10 CFR Part 100.
1258 293 2-9
e b
Other data, however, iridicates that, several hundred meters of displacement along the Devils Mountain fault zone has occurred since the Oligocene (g.a.ater thc' 25 m.y.b.p.) (Miller, personal communication).
Also, Dr.
John Whetten (U.S. Geological Survey pers'onal communication) indicates that as much as 60 kilometers of left lateral movement may have occurred the fault zone.
In addition, high resolution marine seismic profiling in the vicinity of Whidbey Island hs shown some discontinuities in the bodded sediments.
These annaar to be most reasonably attributed to glacial deformation and post glacial slumping rather than tectonir. movement.
We cannot rule out, however, the possibility that the dif f acements are tectonic.
The lack of positive data demonstrating the ratectonic origin of the sediment deformation leaves open the possibility that minor recent movement may have occ"~
a in the Whidbey Island area along the westward projection of the t,a s is Mountain Fault.
Based on the apparent multiple-movement history of the Devils Mountain Fault, the staff considers the waight of the avidanca inadaquata to c nsarvatively concluda that tha fault is not capable within the meaning of Appendix A to 10 CFR Part 100.
Because the Devils Mountain fault zone may be associated with a majo-structural boundary along the southern edge of the San Juan Island plat-form, efforts were made to determine its extent to the west of the mapped portion of the fault zone.
If projected westward, the Devils Mountain fault would be sub parallel but not coincident with the fault bounding the San Juan Islands platform on the south (MacLeod,1977).
On t..e basis of high resolution marine seismic profiling end aeromagnetic surveys (USGS, 1977 and 1978) the staff considers the Devel Mountain Fault to represent a separate fault located somewhat north and t ast of the Southern San Juan Islands Platform fault.
San Juan Islands Platform Faults Seismic reflection profiles obtained within and adjacent to the San Juan Islands area by oil companies, the applicant and the U.S. Geological Survey show that the gross structure of the region can be characterized by a relatively uplifted platform of basement rocks, the San Juan I,slands.
2-10 12r
'94
The platferm is bounded on the north and south by unnamed east-west trending faults of regional extent which separate it from the oeep sedimentary basins.
The northern fault is within 43 kilometers of the Skagit site; the southern border fault is within 32 kilometers.
Vertical displacement of the noethern San Juan Islands Platform Fault appears to exceed one kilometer.
Apparently undisturbed sediments overlying the fault in some areas are at least 300 meters thick.
The structure of the Coastal Trough, north of the San Juan Islano platform, is 09st reveaieo oy a very strong set of reflectors on seismic profiles which range in depth between 1.3 to 2.3 seconds.
These reflectors show that basin strata are continuous and gently dipping throughout that part of the basin covered by the Mobil petroleum exploration survey.
The good quality of the seismic data in this area combined with the configuration of the track lines sugjests an absence of any faulting of regional extent within the basin.
The southern San Juan Islands Platform Fault is reflected in the gravity and magnetic data (Snavely, et al.,
1974; MacLeod et al., 1977; U.S. Geological Survey, Aeromagnetic Map, 1977) as well as by seismic reflection data.
High resolution profiling has been carried out on both sides of Whidbey Island to determine the position of the southern boundary fault of the San Juan Islands platform in that region.
Because of the proximity (21 km) of the Devils Mountain Fault (which is assumed t" be capable) to the proposed Skagit site no final determination of the capability or non-capability of the more distant San Juan Islands Platform Faults has been made because any earthquake event on it would be enveloped by the postulated event on the Devils Mountain f ault. The closest approact of either of the platform faults to the proposed site is 32 km.
Considerable (hundreds of meters) displacement has apparently taken place on each of the faults which art blanketed by an unknown thickness of what may be either Tertiary or Quaternary (perhaps Late Pleistocene) deposits.
Because of uncertainties associateo with the last movement of the platform faults P.nd the undetermined age of the capping sediments, the Northern and Southern San Juan Islands faults are both assumed to be capable.
The U.S. Geological Survey is currently reviewing recently-received seismic profsles taken within portions of the eastern San Juan Islands and the 2-11 1258 295
e Strait of Georgia immediately north of the islands.
Any impact of the USGS's review of these profiles cin the preceeding interpretation will be evaluated by the staff and transmitted at.a later date.
"B and B" Fault Dr. William H. Hays of the U.S. Geological Survey, inferred in Merch,1978 at tne Skagit ASLB nearing Inat a generally nortnwesterly trending fault may extend from west of Lummi Island some 59 km miles to the vicinity of Table Mountain.
This inferred fault would pass within 14 km west of the proposed Skagit Nuclear Power Plant.
The appar;..t bases for Dr. Hays' hypothetical fault (the "B and B") include 1) Dr. Peter D. Ward's 1977 letter to the U.S. Geological Survey suggesting faulting west of Lummi Island and 2) sheared rocks in the vicinity of Table Mountain (approxi-mately 64 km to the soua..ust of Lummi Island).
Dr. Ward, in his letter of December 5, 1977 to Mr. James F. Devine of the USGS, suggests that a large scale strike-slip fault may account for the origin dissimilarities in the rocks exposed on Barnes Island (one of the Sar. Juan Islands) and Lummi Island, about 5 km east of Barnes.
Dr. Ward states that the fault-ing was active during late Cretaceous and/or Tertiary.
Faulting in the Table Mountain area has been reported by various workers including:
1)
Misch in 1967, 2) Miller (in press), and 3) Whetien, et al, in 1979.
We have examined the pertinent available geological and geophysical data as discussed later and conclude that this data dces not support a continuous fault (the "B and B") as described by Dr. Hays.
We believe that faulting does exist in the vicinity of Table Mountain and at least limited faulting appears also to have occurred between Lummi Island and Barnes and Clark islands immediately to the west of Lummi.
We do not find either geological or geophysical evidence supporting continuous linear faulting between Lummi Island and Table Maintain areas. Moreover, the available informa-tion indicates that faulting as described by Dr. Hays, if it were to exist, would be restricted to late Cretaceous-earliest Tertiary time (no younger than 58 m.y.b.p.) and as such would present no hazard to the proposed Skagit plant because it would not be a caoable fault.
This conclusion is based on the fact that Vance's 1975 and 1977(a) work in the 1258 d6 2-12
vicinity of the San Juan Islands suggests that the Late Cretaceous-Paleocene Chuckanut Formation continues westward from Lummi Islano at least as far as Patos Island, some 19 km (Vance, 1975;-Puget, 1979) and is not offset by large scale strike slip faulting as suggested by Dr. Ward.
- Also, Barnes and Clark islands may have been emplaced by post-Nanaimo Group (Late Cretaceous) pre-Chuckanut Formation thrusting within the San Juan Islands such as that suggested by Whetten et al (1978).
In addition, the applicant's recently acquired closely spacea aeromagnetic coverage near Lummi Island does nut support the presence of a continuous linear "B and B" Fault.
Our interpretation of this aeromagnetic data indicates that the trace of the "B and B" Fault, if it were to exist, would underlie and thus predate the Haystack i. rust fault which is at least 80 million years old as established through dating of the Mount Stuart Granodiorite (Whetten et al, in press).
Based upon our interpretation of the information, the staff concludes that there is no strong basis for the projection of a continuous linear fault (the "B and B") between probable faulting southwest of Lummi Island and known faulting in the Table Mountain area.
Geologic evidence offered by Vance (1975 and 1977a) and by Whetten et al (in press) indicate that the faulting west of Lummi Island may be no younger than early Tertiary (58 m.y.b.p).
Additionally, the late Cretaceous (80 m.y.b.p)
Haystack thrust fault (Whetten et al, in press) appears to overlie and is thus younger than the southeastern projection of the hypothetical "B and B" Fault.
Therefore, the "B and B" Fault, even if it existed, would not be capable within the meaning of Appendix A to 10 CFR Part 100 because movement would have ceased prior to 80 m.y.b.p. and would thus present no hazard to the proposed Skagit site.
Bellinoham Bay - Lake Chaolain Fault and Hamilton Fault Geologic concerns expressed by E. S. Cheney, consultant to the interve-nor group, SCANP, include two postulated faults - the Bellingham Bay -
Lake Chaplain (BB-LC) fault zone and the Hamilton Fault (Cheney, 1978).
As suggested by Dr. Cheney, the BB-LC fault zone would trend northwesterly and be at least 350 kilometers in length, probably longer, and would extend in a zone several kilometers wide from Lake Chaplain near Everett, 2-1 1258 297
Washington to at least Bellingham Bay and then into the Strait of Georgia.
ine postulated Hamilton Fault would cross the Skagit valley near Hamilton and would be at least 50 kilometers long.. The BB-LC fault zone would pass some 14 kilometers west of the proposed Skagit site while the Hamilton fault would pass about 6 kilometers southeast of the proposed plant.
~
Based upon analysis of the available geological and geophysical data, including aeromagnetic maps developed both by the U.S. Geological Survey (Open File Reports 77-24 and 75-354) and by tiie applicant (Fuget, 1979) and interpretation of seismic reflection lines conducted within the San Juan Islands and adjacent areas by major oil companies, the U.S. Geological Survey (0 pen File Report 76-187, 1976) and the applicant, the staff concludes that the faults as postulated by Dr. Cheney are not supported by the above evidence and therefore they are not considered further in this review.
2.5.1.2.2 Local Faulting Several faults of local exter.t are present or postulated within the vicinity of the Skagit site.
These include Lovseth's Fault (1975), Whetten's (1979) interpreted Gilligan Creek and postulated Day Creek faults, the Lake Cavanaugh Road Fault, and the postulated Skagit Valley Fault (including the Hamilton Fault as postulated by Cheney (1978)) and as discussed in the previous paragraph.
Lovseth's Fault In 1924, Jenkins mapped a 7 km long unnamed fault in Walker Valley 2.5 km east of Big Lake (19 km southwest of the proposed site).
Jenkins (1924) shows the fault as an approximately N 30* W curvilinear fault trace which abruptly changes strike to N 70* W in T 34 N, R6E, Section 33.
Jenkins provided no further information or field evidence in his report to sub-stantiate this fault.
In 1975, Lovseth briefly reported a high angle fault trending N 30 W in Walker Valley (essentially coincident with Jenkins fault), at the contact between the Chucknut Formation and his rocks of Table Mountain.
In mapped versian, similar to Jenkins (1924),
the northern end of the N 30 W fault changes in strike to N 70* W.
-4 1258 298
g d
Lovseth (1975) provides no discussion regarding the N 70 W trending contact, which is covered by a large landslide.
Investigations by the applicant east and west of the landslide revealed no evidence of a pro-jection of this fault.
The N 30 W segment of this proposed fault is for
~
convenience termed the "Lovseth Fault".
Based on Jenkins' (1924) previous mapping and the linearity of the Chuckanut-Taoie Mountain rocks contact, Lovsetis (1975) coriciucac Ina ti.50 W contact to be faulted, with the sandstone on the west side of the fault highly deformed.
Lovseths' Fault is shown to terminate in a volcanic intrusion which has been dated at approximately 41.5 3.4 m.y. (Lovseth, 1975).
As a result of detailed field mapping the applicant concluded that the contact between the Chuckanut and the metavolcanics (i.e., Lovseth's rock of Table Mountain) is depositional (Miller, in press) showing basal shearing due to Tertiary folding and is not a fault contact as discussed by Lovseth (1975).
The applicant bases this conclusion on:
- 1) the trace of the Chuckanut contact is curvilinear, not linear, and, therefore, inconsistent with the high angle faulting proposed by Lovseth (1975) (similar to Jenkins N 30* W segment) 2) the extension of the mapped Chuckanut contact is at least one mile further to the east than mapped by Lovseth (1975), 3) the applicant has mapped undisturbed andesite dikes in close proximity to the contact, and 4) Tertiary volcanics dated at 41.5 3.4 m.y (Lovseth, 1975) have intruded and overlie the conthet (Lovseth, 1975). In addition, the applicant's aeromagnetic survey indicates no faulting in the area of'Lovseth's fault.
Based on the available data and on observations ma& during several field trips to the fault area, the staff conservatively assumes that the Chuckanut-metavolcanic contact may be fault controlled.
It should also be carefully noted that the present data does not preclude the applicant's interpretation Several factors have influenced the staff's decision:
- 1) the inability to define a clear exposure of the contact or define any characteristics of the actual contact, and 2) the applic.nt's interpretation of fault control to the south in the vicinity of the Tertiary volcanics is lacking, so that is is possibl for the fault to pass to the west of the. volcanics and, therefore, this material
-5 1258 299
wouldnotcherliethecontact. At the same time, the close proximity to the undisturbed andesite bodies (41, 46 and 49 m.y.b.p., Puget, 1979) indicated that since their emplacement, movement has been minimal to non-existent.
No further means of bracketing the ag2 of last mohement of the fault has been found. Therefore, the staff assumes that the fault is capable within the meaning of Appendix A to 10 CFR Part 100 because of our inability to demonstrate otherwise. This fault is not considered of safety significance to the proposed Skagit site due to the fault's proximity to the. larger, assumed capable Devils Mountain Fault. Any event on Lovseth's Fault would beenhelopedbythepostulatedDehilsMountainFaultearthquake.
Gillican Creek Fault Inthespringof1978,Dr.JohnWhettenoftheU.S.GeologicalSurhey suggested that a high angle normal fault may account for the linear trace of the applicant's Shuskan/Chilliwack thrust contact in the valley of Gilligan Creek. The normal fault, located within 6.5 km south of the Skagit site, has been named the Gilligan Creek Fault. Because of the similarity of linearity of the Gilligan Creek area with the Day Creek area (6 km to the eastofGilliganCreek)possiblefaultcontrolwasalsosuggestedinthehalley of Day Creek. Mapping of the Clear Lake NE quadrangle (Whetten et al, 1979) has not altered Dr. Whetten's interpretation of normal. faulting in the Gilligan Creek area. Howeher,afaultintheDayCreekareaisnotincludedonthe mapandisthereforenolongerconsideredinthisrehiew.
Individual' mapping efforts by the applicant and by Whetten et al (1979; in press) haheresultedintwodifferentinterpretationsofthegeologicstructurein the Gilligan Creek area. Theapplicant'sstructuralmodelinvolhestwo northeasterly dipping thrust plates, the Church Mountain overlain by the Shuskan.
Both of these thrust plates are mid-Cretaceous (more than 90 n.y. ago),
(Misch, 1966). The applicant olaces the fault contact between the two thrusts in the east valley wall of Gilligan Creek.
2-16 1258 300
Dr. Whetten's model of the same area is more complex and appears to consist of the following sequence:
- 1) emplacement of the Shuskan and Church Mountain thrusts during the mid-Cretaceous (more than 90 m.y. ago), 2) over-riding of the two earlier thrusts from the south by the Haystack thrust (Decatur Terrane rocks) later in the Cretaceous (88 m.y.b.p.), and 3) post-Haystack faulting (high angle normal faulting) along the east wall of Gilligan Creek. The applicant's GilliganCreekareamodelinholhestwobasicrockassemblages-theDarrington Phyllite (Shuskan thrust plate) and the Chilliwack Group (Church Mountain plate) - separated by a thrust fault.
The Whetten et al (1979) model of the same area would place the Darrington Phyllite in normal fault contact with the Decatur Terrane (Haystack plate).
Thestaffhasrehiewedallahailablegeologicdataandhasmadeseheral field trips into the Gilligan Creek area. As a result of our investigation, the staff concludes that the data supports a model of the Late Cretaceous Haystackthrust(Whetten,etal,inpress)locatedinGilliganCreekhalley, modified by Eocene syncline-folding, not normal faulting. The staff has based this conclusion on: 1) the fact that the aeromagnetic data (Puget, 1979) supports a southerly dipping Haystack thrust emplacing Mesozoic Decatur Terrane roc'.s over the Darrington Phyllite (Whetten, et al, 1979) and
- 2) the fact that the orientation of the foliation and the outcrop: pattern of the Mesozoic Decatur Terrane, the Darrington Phyllite, and the trace of the Haystack thrust supports post-Late Cretaceous synclinal folding, thereby, eliminatingthenecessityfornormalfaultinginGilliganCreekhalley.
It is important to note that all favored models, the applicant, the NRC staff and Whetten, et al (in press), include a late Cretaceous (older than 65 mybp) emplacement of the thrust plates. We conclude that this age of emplacement or last offset for these faults is 65 m.y.b.p. and, therefore, they are not capable faults within the meaning of Appendix A to 10 CFR Part 100 and are not a hazard to the proposed Skagit site.
LakeCahenaughRoadFault FaultinghasbeenobservednearLakeCahanaughaoproximately21kmsouth of the proposed Skagit site. The fault is exposed in a road cut along the 2-17 1258 301
A north side of Lake Cavanaugh Road and, based upon north-south SLAR (Side Looking Airborne Radar) imagery, appears to lie along tne southern end of a NW-SE trending line (lineament) extending from the valley of Gilligan Creek to the Lake Cavanaugh Road Fault.
Since the trend of the lineament (N 25* W) is coincident with the valley of Gilligan Creek which may be, at
~
least in part, fault controlled, the assumption has been made by Dr. Whetten that the Gilligan Creek lineament represents the trace of a fault.
The Lake Cavanaugh Road Fault consists of six en echelon faults cutting glacial lake sediments with accumlative offset and folding of about 7 meters.
The faults trend is to the northeast, between 60 and 70, and dips steeply to the southeast from 55 to 75.
The strike of the Gilligan Creek lineament is roughly N 25* W, nearly perpendicular to the strike of the Lake Cavanaugh Road Fault.
Closely-spaced drill holes made by the applicant for a total distance of approximately 155 meters along the road east and west of the faulted area have encountered a dense till at an essentially consistent depth of about 12 meters.
Maximum relief on the top of the till where crossed by a projection of the fault appears to be no more than 1 meter, unlike the 7 meters of fault movement noted at the ground surface.
Similar minimal relief was encountered on the till top throughout the remainder of the investigated area.
Non-disruption of the till underlying the surficial fault appears to preclude a tectonic origin for this feature.
Westinghouse Corporation SLAR imagery of the Gilligan Creek - Lake Cavanaugh area gives an apparent illusion that the Lake Cavanaugh Road faulting and Gilligan Creek valley to the north form a part of a detectable northwest-trending lineament extending from near the mouth of Gilligan Creek to Lake Cavanaugh - a distance of approximately 16 km.
The suggestion could be made that the lineation is fault-controlled, since it is associated with faulting in the valley of Gilligan Creek to the north and along Lake Cavanaugh Road to the south.
Careful examination of the Westinghouse SLAR (flown north-south) and that obtained by the Corps of Engineers (flow east west) indicates that the Gilligan Creek lineament is not continuous, and apparently consists of a number of non-related separate segments.
The origin of the segments is varied, ranging from the somewhat linear course 2-18 1258 302
of Gilligan Creek on the north to timbering operations and landsliding on the south.
The lineation is not apparent on either the Westinghouse or the Corps of Engineers SLAR imagery at the approximate mid point of the lineament (near the head of Gilligan Creek).
Additionally, interpretation of the aeromagnetic data encompassing this area gives no indication of possible faulting coinciding with the trend of the Gilligan Creek lineament.
The staff concludes that 1) there is minor faulting along Lake Cavanaugh Road about 21 km south of the site and most certainly in the Gilligan Creek valley, 2) that the trend of the Lake Cavanaugh Road faulting does not coincide with the alignment of the Gilligan Creek lineament, but rather is more coincident with the trend of tha nearby (about 1.5 km)
Devils Mountain Fault and 3) that there is no firm basis for assuming that the Gilligan Creek lineament as previously described is totally fault-controlled, extending from near the mouth of Gilligan Creek to the Lake
<E anaugh Road Fault. We also conclude that the origin of the Lake Cavanaugh Road Fault is probably non-tectonic and is most likely attributable to glacial or other near-surface phenomena, possibly slumping.
Skagit Valley Faulting The possibility of faulting in the Skagit valley was considered during our review of the Skagit docket.
The plant site is loca'.ed on the partially eroded northeast limb of a northwest plunging syncline which is oblique to the east-o st trending Skagit valley.
The core of the syncline is comprised of the Chuckanut Formation.
Repetitive regional folding has resulted in an apparent left-lateral offset of the syncline along the trend of the Skagit valley.
In order to define and interpret the geologic and structural framework of the near-site vicinity, the applicant undertook several investigative programs consisting of field mapping, geophysical exploration, and remote sensing studies.
The applicant's investigations 1evealed no evidence suggesting faulting in the Skagit valley.
Based spon our review of the available information the staff concludes that the apparent offset of the syncline across the ulley of the Skagit does not reflect east-west faulting in the vicinity of the site.
Our conclusion is based upon the following:
2-19 1258 303
(1) Geologic and tectonic maps of the area (Jenkins,1924; Rogers,1960; Huntting,1961; Misch,1977; King,1969; Hall and Othberg,1974; King and Beikm*,,1974) indicate no faulting, other than the Shuksan and Church Mountain / Haystack thrusts discussed above in the vicinity of the site.
(2) Gravity data taken in the Skagit valley near the site by the Univer-sity of Washington and the applicant (Smith and Foxall, 1976; Harding /
Lawson Associates, 1975 and 1979) does not indicate faulting.
(3) Seismic reflection surveys made by the U.S. Geological Survey (Snavely, et al., 1976) and Puget Power in the San Juan Islands indicate no faulting, attributable to other than glacial processes, within the area of their surveys along a projection from the Skagit valley to the west.
(4) The U.S. Geological Survey 1977 and 1978 aeromagnetic maps (0 pen File Reports 77-24 and 78-354) of the northern Puget Sound area do not show anomalies indicative of through going faulting either along or tranverse to the westward projection of the Skagit valley.
(5) The deformed Chuckanut synclinal fold axis at the site area conforms with other folds in the region.
(6) The north-south trending Straight Creek Fault of mid-Tertiary age east of the proposed Skagit site crosses the Skagit Valley 48 kms to the east and is not offset by any postulated east-west faulting.
(7) The EDCON aeromagnetic report (Puget, 1979) and map do not indicate anomalies suggestive of faulting either along or tranverse to the westward projection of the Skagit river valley.
(8) The lack of associated seismicity.
2-20 i258 304
2.5.1.3 Volcanism Volcanoes form the core of the Cascade Mountains.
Two volcanoes of the chain, Mount Baker 32 kilometers northeast and Glacier Peak 90 kilometers southwest, are close enough to potentially affect the proposed site.
Potential hazards associated with volcanoes are ashfall, flows (debris, ash and lava), and floods resulting from melted snow and ice from the flanks of the heated volcano.
During its review of the proposed Skagit site, the staff considered both ashfall and debris flow.
Hyde and Crandell (1975) have postulated ash flows and lava flows from volcanic activity of Mt. Baker will move no further than 15 kilometers along valleys heading on the mountain.
The volcanic hazards map of Washington depicts flows of the same dimension (Crandell,1976).
The most extensive lava flow from Mt. Baker was 19 kilometers long; it followed Sulphur Creek, terminating at the Baker River 40 km from the plant site (Coombs, 1939).
This is the closest flow to the Skagit site (Huntting, et al., 1961).
Less extensive flows have occurred in association with activity of Glacier Peak.
The largest moved approximately 8 kilometers from the cone (Huntting, et. al., 1961).
Ash flow and lava are not considered hazards for the proposed Skagit site due to the limited areal extent of these phenomena and the distance separating the site from the nearest volcano.
Ash flows emitting from other Washington or British Columbia volcanoes would not affect the Skagit site.
Ashfall potentially constitutes the most widely distributed volcanic hazard.
Volcanic ashfall is greatest downwind from the source (Wilcox, 1969; Mullineaux, 1974).
Prevailing winds in northwestern Washington based upon the 20 year record (1950-1970) are toward the northeast and southeast sectors.
High altitude winds (3,050 to 8,150 meters) are nearly uniform thrcughout western Washington (Hyde and Crandell,1975).
The proposed Skagit site is located in the southwest sector with respect to Mt. Baker and in the northwest sector with respect to Glacier Peak.
125u 305 2-21
Ashfall distribution from previous volcanic events i'.1dicates that wind patterns have remained consistent during the past 13,000 years (Riggs, 1958).
Fallout patterns of ash emitted from Mt. Mazama, Mt. St. Helens and Glacier Peak are consistent with the present data in that the pre-ponderance of ejecta is located east of the volcanoes (Fryxell,1965; Mullineaux, 1974). Ashfall distribution limits, based upon the largest tephra ejections during the past <0,000 years, has been determined for Mt.
Baker, Mt. Rainier, and Mt. St. Helens (Crandell,1976).
Since triere have been no Glacier Peak tephra eruptions during the past 10,000 years (Crandell, 1976), the 10,000 year Mt. St. Helens fallout distribution pattern was superimposed on Glacier Peak.
Based on its eruptive history and its relationship to similar volcanoes, Mt. Baker is considered to have a low explosive potential (Crandell, 1976).
In the interest of conservatism, the well-documented Mt. Katmai, Alaska ashfall (Griggs, 1922) distribution pattern was superimposed on Glacier Peak.
The ashfall in the site area resulting from a postulated Mt. Katmai type event centered on Glacier Peak is about 7.5 centimeters.
Ashfall resulting from a potential eruption of Glacier Peak is estimated at less than 5 centimeters at the Skagit site (Crandell, 1976).
The Skagit site is located upwind from Mt. Baker and is not situated within the tephra zones considered ha.ardous to either property or human life (Hyde and Crandell, 1975).
Based on the abvte we consider the applicant's suggested 15 centimeters maximum ashfall at the site within a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period to be conservative.
We have also considered debris flows originating from the eastern flank of Mt. Baker.
The debris flow potential for Glacier Peak and other, more distant volcanoes was not evaluated in detail because of their remoteness from the Skagit site.
The applicant evaluated the impact on the Skagit site of a debris flow as large (2 cubic kilometers) as the Osceola flow from Mt. Rainier.
This is the largest known flow from a voir.ano in the Cascade Mountains (Crandeli and Waldron, 1956).
The failure of the Lake Shannon and Baker Lake dams which are on the Baker River downstream from Mt. Baker was considered to occur simultaneously with the postulated flow.
1258 306 2-22
e The combined volume of material, mudflow plus reservoirs of the two dams, 9
would be in excess of 2.52 x 10 cubic meters.
This mass, moving down the Baker River Valley, then the valley of the Skagit, would result in less than 30 meters of debris in the valley below the proposed plant site.
Since the plant is to be situated over 91 meters above the valley, the postulated flow would represent no safety hazard to the propnsed facility.
We consider an "Osceola" type mudflow to be a conservative assumption 7
because a rock mass of 3 x 10 cubic meters (about 65 times smaller thar.
the Osceola) c.'iginating from Mt. Baker is considered to be the maximum reasonable (Hyde and Crandell,1975; Frank, Meier and Swanson,1977).
Based on our review of potential volcanic hazards for the Skagit site, we conclude that a significant fall of ash at the site emitting from Mt.
Baker is inconsistent with the eruptive record of the volcano (Hyde and Crandell, 1975; Crandell, 1976).
Using Griggs's (1922) ash thickness map of the Mt. Katmai event centered at Glacier Peak results in an extm po-lateo ash thickness of about 7.5 centimeters at the Skagit site.
A postulated debris flow was assessed involving an Osceola-type event (Crar. dell and Mullir. eaux,1967), and is approximately 65 times larger than that potential debris flow as suggested at Mt. Baker by Hyde and Crandell (1975) and was found to be of no safety significance.
Even considering the water volumes of Lakes Shannon and Baker combined with the debris, the total volume of the flow would be insufficient to affect the safety of the proposed plant site.
The remaining volcanic hazards (flooding, lava flows and ash flows) have no plant safety implications because they are localized to the volcanic sourc'e area.
2.5.1.4 Geulogy of the Proposed Skagit Site In order to define the geologic structure in the site area, the applicant has made extensive use of exploratory techniques including surface map-ping, exploratory trenching, vertical and inclined drill holes and geo-physical surveys.
The geologic history of the proposed site probably begins with Middle Paleozoic (Misch, 1966) marine shale and other sediments' metamorphosed later in the Paleozoic or early Mesozoic.
Deposition of the 2-23
Late Cretaceous-Early Tertiary Chuckanut Formation followed aetamorphism of the Middle Paleozoic sediments and the regional Middle Cretaceous Shuksan and Church Mountain thrust faulting.
Subsequent to the Chuckanut deposition, at least three periods of regional deformation (Eocene, Oligocene-Miocene, and Pliocene) affected the site.
These deformational periods resulted in folding and associated minor faulting at the site.
There is no record of Tertiary rock units o!.her than the Chuckanut formation at the site.
The Pleistocene to Holocene geologic record at the critical structures area consists of approximately 3 meters of overburden.
No volcanic ejecta have been found at the proposed site.
Soil cover is thin to absent in the critical structures area of the site and where present does not exceed three meters in thickness.
This over-burden consists predominantly of an assemblage of glacially-derived soils.
Bedrock in the plant site consists of Shuksan metamorphics (pre-Jurassic phyllites and schists) and the sedimentary (siltstone and sandstone with some shale and coal) Cretaceous-Paleocene Chuckanut formation.
The thick-ness of these units (Shuksan and Chuckanut) has not been determined, but each probably amounts to several thousand feet in thickness (Miller and Misch, 1963; Misch, 1966).
The proposed Seismic Category I facilities are to be situated on the partially-eroded, steeply-dipping (50* or greeter to the southwest) northeast limb of a syncline which plunges to the northwest.
The syncline is comprised of the folded and reielded Cretaceous-Paleocene Chuckanut Format'7n.
At the site, minor faulting, consisting of adjustments within the Chuckanut as well as along the Chuckanut-Shuksan contact undoubtedly accompanied the Tertiary folding.
In order to demonstrate the structural integrity of the Chuckanut Formation at the site, five distinctive marker beds were traced by the applicant without marker interruption or offset within the area of the proposed power plant structures.
In addition, a distinctive steeply-dipping easterly trending shear zone (Shear Zone A) less than 400 feet long is bracketed by the marker beds.
This shear, according to the applicant, has a maximum 2-24 1258 308
offset of 30 feet and, where observed, is oblique to bedding.
The applicant's investigations concluded that the projection of Shear Zone A beyond its mapped limits shows no discernible offset of the marker beds and most likely gradually dies out assuming bedding plane shears along the eastward and westward projections.
The applicant has determined, because of the minimal detectable length of the shear and its trangression in an east-west direction from a lateral to a bedding plane shear, that the feature is related to the folding of the Chuckanut Formation during the Tertiary and is of no present significant to the safety of the proposed facilities.
The staff has examined the core from those borings passing through the marker beds and finds that these distinctive lithologies can be traced in a northwesterly trend throughout the proposed plant area without detectable offset. We have been unable to find any dislocation of the generally northwest-southeast trending marker beds when assuming a projection of Shear Zone A (which has an east-west orientation), across the trend of the marker beds.
Additionally we have observed no offset of the northwesterly-trending Darrington phyllite-Chuckanut Formation contact where intersected by the easterly projection 'f Shear Zone A.
Based upon our evaluation of the observed core from the ite borings, we find 1) the marker beds are reliable indicators of tructural cite continuity and 2) we have seen no compelling evidence ta suggest that L ar Z0nc A extends beyond the area as manned by the rpplicant.
We also conclude that bedding plane' shearing as well as transverse shearing such as noted at Shear Zone A is of minimal extent n m m likely quite old, being related to Tertiary deformation, This shearing consequently poses no hazard to the proposed Skagit nuclear power plant site within the meaning of Appendix A to 10 CFR Part 100.
Man's activities at the site have included two quarries, a gravel pit and two local coal prospects.
The two quarries are within the Chuckanut Formation approximately 90 m and 880 m southeast of the Seismic Category I structures, while the gravel pit is about 730 m southwest of the nearest critical stracture.
No commercial coal mining has been reported at the site but two short (less than 20 m) exploratory adits are located within the site boundaries.
The closest approach of either adit to the critical structures area is approximately 580 m.
These past activities of man, due 2-25 1
to their limited nature and remoteness, present no hazard to the proposed plant structures.
Furthermore, future commercial mining activities will be prohibited at the site since mineral rights are retained by the appli ant.
No commercial coal mining activity has occurred in the site area, other than at the Cokedale Mine about three km to the northwest of the plant (Jenkins, 1924; Livingston, 1974).
Production ceased at the Cokedale mine in 1921 (Jenkins, 1924). Jenkins (1924) shows coal prospects, but no mines, along Powell Creek located near the western site limit, within 580 m northwest of the proposed plant.
Jenkins observed a 70 cm coal bed, partially weathered and containing shale partings, along the roadway north of Minkler Lake about 980 m southeast of the proposed plant.
We have concluded that past coal prospecting presents no hazard to the proposed plant structures because of their limited extent and distance from safety-related structures.
The possibility of coal beds within the Chuckanut formation burning in place and posing a hazard to the proposed nuclear plants is considered extremely remote, perhaps impossible because of two primary reasons 1) the lack of continuous, extensive coal beds beneath either of the proposed plants, and 2) the high ground water table throughout the area of the plants.
Exploratory investigations, including drill holes and trenches do indicate steeply-northwesterly dipping coal beds up to 3.5 feet thick beneath the plants.
However, based upon the investigations, the coal beds are discontinuous, grade laterally into non-combustible lithologies, and do not extend beyond the general power plant limits, thus preventing access to the plant area from an off-site coal fire (in the extremely unlikely event that a fire would occur).
One common method of extinguishing many fires is by the application of water.
Subsurface investigations within the proposed plant areas have demonstrated that the ground water table here ranges from above ground level (artesian conditions) to a depth of 3.6 meters below the surface.
The average depth is approximately 2 meters.
Combustion of the coal would appear to be highly unli:?ly under these conditions.
Based upon the above rationale, the staff does not consider that coal bed fires constitute a potential safety hazard to the proposed Skagit nuclear facility.
3758 510 2-26
From our analysis and evaluation of available geologic data, including the results of investigations performed by the applicant, we have concluded that there are no geologic considerations that would preclude the accept-ability of the site.
Although the Chuckanut Formation has been deformed, locally sheared, and faulted, the deformation took place during the Tertiary (Mayers and Bennett, 1973; Thornbury, 1965; Misch, 1966) and no longer presents a hazard to the site.
Investigations by the applicant have revealed no evidence of recent faulting in the site area.
Man's activities, consisting of removal of stone and sand and gravel represent no hazard to the proposed site because of their limited extent, and distances from safety-related structures.
The exploration for coal during the past does not cause a safety hazard because the site adits were exploratory, and of limited extent. We base our conclusions relative to the size and location of the adits upon:
(1) no evidence of former subsurface workings in an extensive northeasterly-trending trench by the applicant within the area of each of the proposed units, (2) no voids indicative of previous, un-reported mining activity were encountered during the investigations of the proposed site, (3) a lack of evidence in the site quarry supportir.g former coal mining activity southeast of the plant locations, and (4) no acknow-ledgement in the literature (Jenkins,1924; Livingston,1974) of commercial coal mining operations at the proposed site., Since neither mining nor exploration beneath the proposed site will be permitted in the future (due to ownership of the mineral rights by the applicant) coal prospecting will be prohibited and consequently presents no hazard to the proposed plant.
The applicant has agreed to geologically map, in detail, geologic features exposed in the excavations for all Seismic Category I structures, including Seismic Category I pipelines.
In addition, similar mapping will be conducted within other excavations related to nonsafety structures if required to adequately interpret the site geology.
The NRC staff will visit the site during, or shortly af ter, mapping of the excavations is complete in order to make an independent evaluation of the site geologic conditions.
2-27 1258 311
2.5.2 Vibratory Ground Motion 2.5.2.1 Regional Tectonics The tectonic deformation of Western North America appears to be intimately related to the interaction of two major lithospheric plates, the North American Plate and the Pacific Plate.
The interaction is principally along two major transcurrent faults, the San Andreas Fault in Califoraia and the Queen Charlotte Fault off Western Canada.
However, in the area between Cape Mendocino in northern California and the southern extent of the Queen Charlotte Fault off the western tip of Vancouver Island, the two major plates named above are separated from one another by the small Juan de Fuca Plate.
The interaction between the Juan de Fuca Plate and the North American Plate is not presently understood.
The magnetic anomaly pattern east and west of the Juan de Fuca Ridge indicates that part of the Juan de Fuca Plate has been subducted beneath the North American Plate.
Also, the chain of stratovolcanoes which forms the axis of the Cascade Mountains is believed to have been produced by magma from a subducting plate (Atwater, 1970).
Several other types of data indicate that an episode of late Cenozoic subduction occurred in this region of western North America.
Seismic reflection surveys off the coast show a sediment-filled trench at the base of the continental slope (Hays and Ewing, 1970).
Anomalously high gravity values on Vancouver Island are suggestive of a remnant subducting slab beneath the region (Stacey, 1974).
Seismic wave velocities indicate that a high velocity slab exists beneath the Puget Sound Basin (McKenzie and Julian, 1971); Crosson, 1972) which is indi-cative of a subducting lithospheric plate.
Other evidence indicates, however, that subduction along the Juan de Fuca Plate-North American Plate boundary is not currently occurring.
In parti-cular, earthquake activity indicative of a Benioff zone (a characteristic of subducting plates) is absent in this region. Also, the orientation of the present regional stress field is inconsistent with active subduction.
Analysis of earthquake source mechanisms show that the maxi.num principal 1258 312 2-28
stress is north-south compressional and the minimum principal stress varies from east-west to nearly vertical (Crosson, 1972).
While the available data are not clearly definitive, the staff believes they support the interpretation that subduction may no longer be occurring along the Juan de Fuca-North American Plate boundary.
The applicant proposed that the geological and seismic characteristics of the tectonic elements within the site region provide a basis for subdividing the Pacific Northwest into several tectonic provinces.
These subdivisions are referred to in the Preliminary Safety Analysis Report as the southern Puget Sound subprovince, the Western north Cascades subprovince, and the Eastern North Cascades subprovince.
The Southern Puget Sound subprovince corresponds directly to the Puget Trough.
The Western North Cascades subprovince consists of that portion of the North Cascades west of the Cascade core, including the San Juan Islands Platform and the stratovol-car.oes.
The Eastern North Cascades subprovince is described as that portion of the Pacific Northwest east of the eastern edge of the Cascade Mountain core and north of the Columbia Plateau.
The applicant did not define the eastern or the exact southern boundary of this subprovince.
The Eastern North Cascades Tectonic Subprovince is distinguished from the Western North Cascade Mountains on the basis of structural geology, volcanology and seismicity.
Structurally, the Eastern North Cascades subprovince is characterized by north-westerly trending Tertiary grabens, bounded by normal faults of large displacements.
The faults apparently have no counterparts in the Western North Cascades Subprovince.
The subprovince exhibits no evidence of the Pleistocene volcanism which is characteristic of the Western North Cascades Subpravince.
In contrast to the low seismicity defined in the Western North Cascades Subprovince and the lack of seismicity in the Cascade core, the applicant considers that the Eastern North Cascades subprovince to exhibit high seismicity, particularly in the Entiat and Chelan, Washington area.
The staff agrees that the cited geologic data generally supports differences in structural characteristics among the proposed tectonic provinces.
However, the staff cannot concur that the tectonic provinces described 1258 313 2-29
provide a suitable basis for determiing the safe shutdown earthquake for the site on the bar,is of currently available data.
The entire region has experienced considerable tectonism in Quaternary time. With the exception of the Puget Trough discussed below, historic seismicity does not clearly distinguish the proposed provinces.
The Puget Trough, the northern portion of the Puget Lowlands as defined by Livingston (1969), is characterized as a linear downwarp which parallels the Cascade Mountains on the west and extends fom the Olympia lineament on the south to the southern San Juan Islands platform fault.
The Puget Trough shows geologic evidence of continued tectonic acti tity from the Tertiary into the Holocene and a continuing relatively higher level of seismicity.
This downwarp has been actively subsiding since Tertiary, as demonstrated by thick deposits of Tertiary rocks and extensive accumulation:,
of unconsolidated sediments (Hall and Othberg, 1974).
These sediments which are probably post-Tertiary in age, reach a thickness of at least 1,100 meters near Seattle, Washington.
Major structural blocks bounded by northwest and east-west trending faults represent the present structural
- ramework of t.ie Puget Trough.
These faults have been interpreted from gravity data by Danes, et al., 1965, and Rogers, 1970.
The intensity of the gravity anomalies in the region is such that faults having as much as 10 kilometers of recent displacements are indicated (Danes, et al., 1965).
The historic seismicity of the Puget Trough indicates a significant spatial variation in the frequency of earthquake occurrence.
The southern portion of the Puget Trough exhibits about 70 percent of the historic earthquake activity within the entire Puget Trough. This pattern of historic earthquake activity has been confirmed by the distribution of accurately located earthquakes during the past five years (Crosson, 1974 and 1975). Four large subcrustal earthquakes have also been concentrated in the southern Puget Trough (Algermissen and Hardins, 1965). These earthquakes are discussed below in Secticn 2.5.2.2, Maximum Historic Earthquakes.
1258 M 4 2-30
2.5.2.2 Maximum Historic Earthquakes Moderate to large earthquakes have occurred within 200 miles of the pro-posed Skagit site during the 134 year historic record.
A discussion of tha principal parameters of each earthquake together with estimated intensity that each produced at the proposed Skagit cite is given in Preliminary Safety Analysis Report Section 2.5.2.5.
The three largest historic earthquakes within the proposed Skagit site region occurred December 14, 1872, June 23, 1946, and April 13, 1949. The applicant's consultants developed detailed information on the 1872 earthquake in order to define its maximum int,insity and epicentral location.
Subsequent reviews of this extensive data base by the applicant and by a panel of experts convened by the utilities of the Pacific Northwest, and also by the U.S. Geological Survey /NOAA Ad Hoc Working Group resulted in some clarification of the parameters of the 1872 event.
The applicant's investigation indicated the epic. enter of the 1872 event was in central Washington, near Lake Chelan.
The applicant proposed that the 1872 earth-quake was magnitude 6.5 to 7.0, with a maximum Modified Mercalli intensity of a strong VIII and a felt area of approximately 777,000 square kilo-meters (300,000 square miles).
The panel of experts, which consisted of Ors. Otto W. Nuttli, W. G. Milne, David B. Slemmons and Howard A. Coombs, reached a similar conclusion regarding the intensity, but considered the felt area to be approximately 1,300,000 square kilometers (500,000 square miles) based on intensity III isoseismals.
They considered the epicentral area to be within a region north of Entiat to the Canadian border.
No magnitude determination was developed, but the panel indicated that the event was not shallow, i.e., less than 10 kilometers.
The U, S. Geological Survey /NOAA review panel resulted in similar param-eters for the 1872 event with the exception of the intensity value which was conservatively assigned a Modified Mercalli IX.
The applicant estimated this earthquake produced a maximum intensity of VI to VII at the propose 1258 315 2-31
Skagit site.
In a letter to the NRC's L. V. Gossick, dated November 15, 1977, the Advisory Committee on Reactor Safeguards (ACRS) and its consultants concluded that the 1872 earthquake should be considered as an Intensity VIII.
The 1946 British Columbia earthquake has been evaluated several times in regard to its epicentral location.
The questionable epicentral location and causative structure for the 1946 British Columbia earthquake prompted scientists (Hodgson Tnd Milne, 1951; Hodgson; 1946; Wickens and Hodgson, 1967) to develop several epicentral locations for this event and associate
't with both northeast and northwest trending structures.
The applicant adopted the recent relocation of the 1946 British Columbia Earthquake as approximately 50*N latitude and 125*W longitude, 10 kilometers inland on the east coast of Vancouver Island, as developed by Aogers (1975) and associated the earthquake with a northeast-trending structure.
One of the most recent interpretations (Rogers,1975) and that adopted by the applicant, is that the 1946 earthquake occurred on the east coast of Vancouver Island near the Strait of Georgia, approximately 274 kilon iters from the proposed Skagit site.
The magnitude of this event was detern,'ned to be 7.3 with a felt area within the continental United States of 259,000 square kilometers (100,000 square miles) (Cofmann and Von Hake, 1973).
The applicant estimated that the 1946 British Columbia earthquake produced a maximum intensity of VI at the proposed plant site.
The largest historic earthquake in the southern Puget Sound (magnitude 7.1 and maximum intensity MM VIII (Rasmussen, 1967)) occurred between Olympia and Tacoma on April 13, 1949, 185 kilometers from the proposed site.
The applicant estimated that this earthquake produced a maximum intensity of MM V at the proposed Skagit site.
On April 29, 1965, February 14, 1946 and November 12, 1939 three moderate earthquakes occurred in the area of deep subcrustal tectonism and high seismicity discussed in relation to the Puget Depression.
The closest of thes,e to the proposed site was 130 kilometers to the southwest near Seattle, Washington on April 29, 1965.
Its mcgnitude was determined to be 6.5 and the maximum intensity was MM VIII (Rasmussen, 1967).
The intensity at the 125B M
,_3,
proposed Skagit site from this earthquake was estimated by the applicant to be no more than MM VI.
The two remaining subcrustal events in the Puget Sound were MM intensity VII (Rasmussen, 1967, Cofmann and Von Hake, 1973), and occurred November 12, 1939 and February 14, 1946.
The 1939 event was located approximately 130 kilometers from the proposed site and had a felt area of 155,000 square kilometers (Rasmussen,1967).
The applicant estimated a site intensity for this event of IV MM.
The 1946 event was located approximately 152 kilor,eters southwest of the proposed site and had a felt area of 70,000 square miles (U.S. Earthquakes,1946).
Sedro Woolley reported intensity III from this event.
In addition to the subcrustal events recorded in the Puget Sound, on May 16, 1976 a magnitude 5.5 earthquake with a focal depth of 62 kilometers occ.
-d near the southern tip of Vancouver Island.
No estimate of proposed site intensity was given for this event.
Two shocks of epicentral intensity MM VII (Cofmann and Von Hake, 1973) occurred 65 kilometers northwest of the proposed Skagit site on January 11, 1909 and January 23, 1920.
The 1909 event had an estimated felt area of 65,000 square kilometers (Milne, 1956).
The applicant estimated the proposed site intensity as V.
Based on an analysis of newspaper accounts of the 1920 event, the applicant determined the epicentral intensity to be Mod!fied Mercalli VI and a proposed site intensity as Mod'fied Mercalli III-IV.
The nearest kr.own earthquakes to the proposed Skagit site occurred on December 15, 1974, April 8, 1975, and October 13, 1977. The first two were both 6.5 kilometers southeast of the proposed site and had magnitudes o' 3.0 and 2.7 respectively.
The applicant conducted field mapping, remote sensing and a geophysical program to ascertain the possible relation of these two events to a causative structure.
The October 1977 event occurred 3 kilometers southwest of the proposed site, but did not trigger the strong motion accelerograph at the proposed site which was set to begin recording at.05g.
The geophysical program and seismic investigations established that the 1974 and 1975 earthquakes and aftershocks were clustered 2-33 k
in an area of less than one kilometer (Smith and Foxhall,1976).
Additional velocity data gathered by the geophysical program enabled a reevaluation of the fault plane solutionr for the aftershock of the December 15 event indicating a fault plane striking N26*E with reverse movement (Smith and Foxhall, 1976). A gravity survey was also conducted near the epicentral area to determine whether faulting might exist along the Skagit valley near the epicenter of the December 15, 1974 event.
This gravity data indicate the existence of a buried ancient river channel and shows no indication of control by faulting.
As a result of thorough initial investi-gations, no additional studies were deemed necessary by the applicant to conclude that these earthquakes were not related to surface faulting but most likely associated with shallow crustal adjustments or local relief of stress.
The earthquake of December 15, 1974 produced a maximum intensity of VI in the thick alluvial and glacial materials of the Skagit valley, but was not felt at the proposed site.
The earthquake of April 8,1975 produced a maximum intensity of IV in the valley, but again was not felt at the proposed site.
The earthquake of October 13, 1977, was not felt at the proposed site nor was an intensity value determined for this event.
2.5.2.3 Safe Shutdown Earthquake Applicants' Position The historical earthquakes considered by the applicant as having an effect on the proposed Skagit plant site are the intensity VIII British Columbia earthquake of 1946, the April 13, 1949, and April 29, 1965 intensity VIII earthquakes of the southern Puget Sound and the intensity VIII+ December 14, 1872 earthquake.
The applicant's analysis of the April 13, 1949 and April 29, 1965 intensity VIII, suberustal Puget Sound earthquakes and their effect at the proposed Skagit site were approached in three different ways.
The applicant assumed t;,at (1) these large earthquakes are associated with the subducted remnant of the Juan de Fuca plate, (2) that these events are crustal in origin an 125B 2-34
should be restricted to the Southern Puget Sound subprovince directly associated with the major deep crustal faulting (Danes, et al., 1965, Rogers, 1975) and (3) that these events are random crustal events and assumed to occur at the northern boundary of the Southern Puget Sound subprovince.
After careful analysis of seismicity of the Puget Depression as depicted by Crosson (1972) and Harding and Algermissen (1965), in light of plate tectonics as it is known in the Pacific Northwest, the applicant concluded that the large subcrustal earthquakes in the southern Puget Depression might reasonably be related to the subducted portion of the Juan de Fuca plate beneath the Puget Lowlands. The applicant developed a schematic drawing of the subduction zone at the latitude of the April 29, 1965 event (Fig.2.5-28i) based upon studies by Issac, et al., (1968), Silver, (1972), McKenzie and Julian (1971), and Dickerson (1970).
Assuming the figure to be applicable at the latitude of the proposed plant site, with a modification to account for the westward curvature of the subduction zone (Atwater, 1970, Crosson, 1972), the applicant concluded that a similar event occurring along the top of the subducted plate at its closest approach to the proposed site would indicate a hypocentral distance of 80 kilometers resulting in an intensity VII or less at the proposed site.
According to the applicant, the maximum acceleration on rock at a distance of 80 kilometers from a magnitude 7.1 earthquake would be no more than.10g (Schnable and Seed, 1973).
Karsberg (1967), Sylvester, et al., (1971) and Algermissen and liarding (1965) all noted and discussed in varying detail the possible association of the deep major block faults of the Southern Puget Sound subprovince to the large subcrustal earthquakes.
After a review of the available literature, which included focal mechanism studies of the large Puget Sound earthquakes and the available geophysical data, the applicant concluded that the largest earthquakes -- the 1949 or 1965, intensity VIII events -- were assumed to recur along these respective structures at their clocest approach to the proposed plant site.
The applicant concluded that the resulting intensity at the proposed plant site would prcbably not exceed VI.
Acknowledging the fact that these large events may be considered rande~
n 2-35
and not directly relatable to structure, the applicant applied the tectonic province approach as defined within the meaning of Appendix A to 10 CFR 100.
Assuming that the earthquake recurred at the northern boundary of the Southern Puget Sound subprovince located approximately 32 kilometers from the proposed site, the applicant concluded that the resulting intensity at the proposed plant site would be VII, with a peak acceleration of.15g and an effective acceleration of about.12g (Schnabel and Seed, 1973).
The December 14, 1872 earthquake was located, as a result of extensive investigations by the applicant, east of the Cascades in the Wenatachee-Chelan, Washington area.
In an attempt to determine the causative structure for this event, the applicant conducted geological investigations in the Wenatachee-Chelan regi ' which included mapping, photo analysis, discussions with local geolc p
plus a review of historical seismicity.
The applicant attempted to sr.- t 2t the tectonic history of the 1872 epicentral region indicates a te.:urrence of structural deformstion along generally aligned northwest-southeast trending axes.
According to the applicant, sufficient evidence was gathered during the investigation to reach the conclusion that the 1872 event can be reasonably associated with the northwest trending Badger-Entiat Uplift or the adjacent Entiat Faust, which marks the western boundary of the uplift.
It is, therfore, the applicant's position to conservatively assume that the 1872 event could recur on either northwest trending structure at its closest approach to the proposed plant site.
The event would be 97 kilometers (60 miles) from the proposed Skagit site and according to the applicant would result in an intensity VII or less at the proposed site.
The analysis of the December 14, 1872 earthquake and the effect on the proposed Skagit site also was approached by applying the tectonic province method as discussed in Apoendix A to 10 CFR Part 100.
In doing so, the applicant assumed the event to occur on the western boundary of the Eastern North Cascades province (described in Seciton 2.5.2.1 of the Preliminary Safety Analysis Report) located 80 kilometers (50 miles) from the pr.oposed plant site, and at this location would not produce an intensity greater than VII at the proposed site.
2-36
As a result of the arguments discusssed above, the applicant considers that the maximum historic earthquake at the proposed Skagit site is intensity VII.
However, for additional conservatism, the applicant increased the maximum earthquake to intensity VIII at the proposed plant sita.
The proposed intensity VIII provides a large factor of safety according to the applicant, in view of the fact thal..>e reactor at the proposed Skagit site will be built on competent bedrock whereas the only intensity VIII Puget Sound earthquakes have been recorded on soils.
Using the intensity-acceleration relationships by Newman (1954) and Coulter, Waldron and Devine (1973) (i.e., above average fi.
Dedrock), the applicant concluded for an intensity VIII maximum earthquake that a.25g reference acceleration is adequately conservative.
In order to provide additional conservatism, the applicant elected to use.35g as the reference acceleration for the proposed Skagit site.
NRC Staff Position The staff's review of the vibratory ground motion potential for the proposed Skagit site was conducted to determine a conservative value for the intensity and resultant ground acceleration for the safe shutdown earthquake.
As stated in Safety Evaluation Repcrt Section 2.5.2.1, the staff feels that an evaluation of the seismic hazards at the proposed Skagit site more realistically involves consideration of the regional tectonics as a remnant plate margin rather than delineation of tectonic provinces based on surface geologic structures.
The proposed site is located near and somewhat seaward of the volcanic chain along the Pacific Northwest. While this chain of volcanoes was probably generated by mid-to-late Tertiary subduction of the Farallon plate, there are reasons, discussed bels.?, to think that the tectonic regime has now evolved considerably from that of a typical subducting margin.
At present, much of the seismicity of the Pacific northwest may be derived from two regional tectonic processess:
(a) a remnant subduc'1on zone in which the present convergence rate is probably several centimeters a year or less, and (b) a shearing force exerted by the northwestward movement of the Pacific plate on the remnant Farallon plate, possibly in jhb 2-37
the vicinity of the Mendocino and Blanco fracture zones.
The remnant Farallon plate is often referred to as the Juan de Fuca plate.
These models - remnant subduction model and shear model -are not mutually exclusive and some aspects of each probably influence the contemporary tectonics of the Sacific northwest.
Neither of these tectonic models necessarily exclude a regional stress contribution from other possible sources of which the staff is currently unaware.
Under these two models there are potentially five seismic sources which require evaluation for assessing vibratory ground motion at the proposed site:
(1) Subduction Interface Large thrust earthquakes associated with movement along the subduction interface do not constitute a hazard to the proposed plant site.
Comparisons of this margin with other subducting margins around the Pacific present clear evidence that large thrust earthquakes (m >
7.0) should not be expected as a result of interaction between the Juan de Fuca (Farallon) plate and the Americas plate.
Locations along subduction zones with a history of large thrust earthquakes are characterSed by well-defined dipping Benioff zones and by focal mechnisms w.lich indicate shallow-angle thrusting.
Despite the occurrence of several earthquakes in the Puget Sound region at hypocentral depths near 60 kilometers, the seismicity of the area does not define a Benioff zone.
Neither are there, to the staft's knowledge, published focal mechanism studies which indicate shallow angle thr'Jsting.
These two observations constitute sufficient evidence to conclude that large earthquakes should not be expected on the interface and are not a hazard to the proposed plant site.
Nevertheless, there is considerable additional evidence which supports this conclusion including:
\\19 2-38
(a) The shallow water depths offshore:
segments of subdur. ting margins from vlich large shocks are absent or near absent are i
characterized by shallow oceanic seafloor; (b)
The absence of a well-developed trench:
subduction zones where large shallow thrust earthquakes occur have well developed off-shore trenches; (c) The absence of great thrust earthquakes during historic time:
one hundred years of data are not insignificant because an entire margin is involved (Mendocino Fault Zone to Vancouver Island) and not an isolated segment or seismic gap; (d) The relative youth of the oceanic lithosphere within the Juan de Fuca plate:
subductions zones where large shallow thrust earthquakes occur have significant portions of oceanic lithosphere which is Oligocene or older (23 million years before present).
By contrast, the 91 dest portion of the Juan de Fuca plate is late Miocene (about 10 million years before present);
and (e) The relatively high heat flow within the Juan de Fuca plate:
this is indicative of the youth of the plate, and by inference suggestive of the inability of the plate to sustain the stresses necessary for great earthquakes.
(2) 1946 Vancouver Island earthquake.
There is reasonable evidence that the plate margin near the northern half of Vancouver Island responds to a different regional stress pattern than does the remainder of the margin.
Based on magnetic evider.ce, the northerly portion of the Juan de Fuca plate may have been decoupled from the remainder of the plate during the past 10 million years (Riddihough, 1976, 1977).
The larger shocks of Vancouver Island, including the 1946 shock, occur in the northern part of
Vancouver Island, that is, landward of the potentially decoupled portion of the plate (G. Rodgers, 1976, personal communication).
Finally, the focal mechanisms of earthquakes near the northern portion of Vancouver Island are consistently strike slip including a reanalysis of the 1946 event (G. Rodgers, 1976).
For these reasons, Rodgers groups the 1946 earthquake with other events of the northern portion of Vancouver Island. While the sum total of this evidence does not establish the existence of a separate plate (tentatively named the Explorer plate by Riddihough), the evidence does indicate that the tectonic style is distinct through the northerly portion of the margin and that, therfore, a tectonic bound can reasonably be drawn somewhere across the southern portion of Vancouver Island.
(3) Intraplate events within subducted portions of the Juan de Fuca (Farallon) Plate, i.e., events similar to the 1949 or 1965 Seattle earthquakes.
Since earthquakes with hypocentral depths near 50-60 kilometers were reported near the southern tip of Vancouver Island (Milne, personal communication, 1976), it shald be assumed that events similar to the 1949 or 1965 Seattle earthquakes could occur further to the north, beneath the proposed site at a depth of about 55 kilometers.
A survey of twelve published curves presenting empirical relationships between distance and acceleration for earchquakes cf magnitude 7.5 show accelerations of.3g or less at a distance of 50 kilometers (PSAR for WPPSS Nuclear Project No. 3, Fig. 2.5-57b).
The earthquakes of 1949 and 1965 generated intensities near VIII MM at the ground surface which are equivalent to a reference acceleration of.26g (Trifunac and Brady, 1975).
(4) The 1872 earthquake of the Pacific northwest.
This large event occurred to the east of the chain of active volcanoes and, therefore, a recurrence of such an event should be postulated no h
2-40
closer than 32 kilometers (20 miles) from the proposed plant site, the approximate midpoint of the band of volcanoes.
Implicit in this reasoning is the staff's position that the chain of active volcanoes is a clearcut, seismotectonic boundary.
A summary of attenuation curves contained in the PSAR for WPPSS No. 3 (Fig. 2.5-576) indicate that an earthquake of magnitude 7.5 would attenuate over a distance 32 kilometers (20 miles) to a value of.35g or 1ess. While the magnitude of the 1872 earthquake is unknown, data support a value less than 7.5.
(5) Earthquakes associated with the Devils Mountain fault zone.
An earthquake of magnitude about 6.5M is a conservative estimate of s
the largest event which might be as ciated with movement on the Devil s Mountain fault zone.
This conclusion is based on (a) the absence of clearcut seismicity evidence to delineate the fault zone, and (b) a comparison with similar tectonic settings, i.e., near the seaward side of volcanic chains. While exceptions to this statement occur, i.e., earthquakes of magnitude greater than 6.5, it is important to note that these exceptions were located near extremely active subduction zones which have experienced the largest known earthquakes.
Based on Schnabel and Seed (1973), an earthquake of magnitude 6.5 would generate average accelerations of about.27g at a distance of 21 km (13 miles).
Based on the for:[0ing analyses, the staff concludes that a seismic design value of.35g horizontal acceleration is adequately conservative for the proposed Skagit site.
2.5.2.4 Operating Basis Earthquake The applicant committed the design vibratory acceleration for the operating basis earthquake to te.175g, one-half of the safe shutdown earthquake consistent with Appendix A to 10 CFR, Part 100.
2-41
2.5.3 Stability of Subsurface Materials and Foundations 2.5.3.1 Subsurface Conditions The proposed Skagit Plant will be founded on a glaciated bedrock bench located on the margin of the North Cascade foothills above the Skagit River Valley.
Structurally, the rock bench is a truncated limb of a synclinal fold of sedimentary rocks of the Chuckanut Formation.
The rock is a thick massive bedded sandstone and siltstone with interbedded shales and coal seams; it exhibits numerous shear zones.
The rock beds dip steeply to the,outhwest at about 50 degrees on an average strike of N55W.
The geology of the site is described in detail in Section 2.5.1.5 of the Preliminary Safety Analysis Report, "Ge.? logy of the Proposed Skagit Site."
The existing ground surface in the area of plant structure has a maximum elevation of 484 feet (U.S. Geological Survey Datum) and gently slopes away from the proposed plant site to the southwest, west, and also to the north towards Black Creek.
Plant grade will be at elevation 415.
The depth of soil overburden varies from a thin veneer of about 10 feet in thickness in the area of proposed plant structures to a maximum depth of about 95 feet north of Unit 1 in the vicinity of Black Creek.
Overburden soils consist of a few feet of recent alluvium underlain by undifferentiated glacial drift materials consisting of loose to dense silty to gravelly sand varying in thickness up to a maximum of 27 feet.
Underlying the glacial debris is dense glacial till classified as a silty, gravelly, fine to coarse sand which has an average Standard Penetration resistance of 100 blows per foot.
In the area of proposed plant structures the till has been eroded and only exists sporadically in thin layers but has a maximum thickness of 65 feet in the Black Creek drainage basin north of the proposed plant.
Groundwater levels range from near the existing ground surface to 31 feet below the ground surface, and are subject to fluctuation corresponding.to variations in precipitation which is the only source of recharge.
The groundwater level used for design purposes is discussed in Section 2.4.4 of the Safety Evaluation Report, NUREG-0309, " Groundwater."
Q 2-42
2.5.3.2 Foundations for Structures Main Plant Structures Proposed Category I structures, with the exception of the diesel fuel oil storage vaults and the Cat.egory I piping system between the main plant and the ultimate heat sink, will have mat foundations founded on hard rock or fill concrete extending to hard rock.
The excavations for the structures will extend a maximum dapth of about 20 feet into rock material for Unit 1 and 50 feet'for Unit 2.
The level of hard rock is below foundation grade in the southwest areas of Unit 1 where portions of the foundations for t:1e containment and enclosure building and auxiliary and fuel buildings will be placed on fill concrete extending to a maximum depth of about 20 feet.
The staff reviewed preliminary design details and specifications for placement of fill concrete and related foundation preparation (Drawing No. SK-C-558 Rev. A and Specification 10363-C 106) and finds them acceptable.
Placement of fill concrete will be subject to quality assurance requirements of Appendix B of 10 CFR Part 50.
The containment and enclosure building for each of the two proposed units will be founded on a circular mat, 145 feet in diameter which exerts a total static load of 9,520 pounds ;.ar sqvare foot.
Other proposed Category I structures, the auxiliary building, control building, fuel building and diesel generator building, will be founded on independent mat foundations with total loads ranging from 2000 pounds per square foot to 3600 pounds per square foot.
The staff agrees with the applicant's estimate that total and differential settlement of these Category I structures will be negligible.
Ultimate Heat Sink Each proposed reactor unit will have a Category I water storage pool for the redundant mechanical draft cooling towers that provide the emergency cooling water for plant shutdown.
These pools and towers will be located about 200 feet to the southwest of the reactors of each unit.
The storage h
2-43
pool will be a reinforced concrete box structure about 60 feet deep supported by a mat foundation 155 feet by 145 feet founded on hard rock at about elevation 340.
The excavation for the ultimate heat sink pools for the proposed Units 1 and 2 will extend to a maximum depth of about 50 feet into hard rock.
Construction of the ultimate heat sink pool for the proposed Unit 2 will require excavation into Bacus Hill, a rock ridge that extends above eleva-tion 600 and is located at the southeast edge of the proposed plant site.
The applicant has completed a stability evaluation of the excavation slopes based on information obtained from outcrops and drill hole data regarding bedding and fracturing characteristics of the rock.
There are several high angle fractures dipping northward.
However, experience with deep cuts in rock in early exploratory trench excavation indicates the rock is blocky and fracture planes are commonly irregular and discontinuous.
However, because there is some uncertainty, the staff recommends that a more detailed stability evaluation be completed during construction when the excavated faces are exposed which will permit direct inspectian of existing rock conditions.
It may be necessary to employ rock anchors and drains to stabilize local rock masses or it may be desirable to remove additional rock.
The applicant should provide the staff with a special report of the detailed evaluation of as built conditions of the rock slopes during construction together with a description of action taken to stabilize rock masses; geologic mapping of the excavated faces should also be provided, as soon as this information becomes available.
The rock foundation is adequate to support the ultimate heat sink structures and the staff oncurs with the applicant's estimate that total and differential settlements of these structures will be negligible.
Category I Pipelines The proposed Category I pipelines that connect the ultimate heat sink to the containment and auxiliary building will be founded on dense glacial till (average Standard Penetration resistance greater than 100 blows per 2-44
\\
foot), bedrock, or a mat of compacted engineered fill consisting of sand and gravel.
The gradation of the fill material given in the Preliminary dafety Analysis Report in Section 2.5.4.5 is acceptable.
The maximum 6epth of engineered fill that may be required will be about 25 feet for Unit 1 piping and about 10 feet for the Un'c 2 piping. A bedding of sand 12 inches thick will be placed under all proposed Category I piping for both Units 1 and 2.
Backfill between the rock excavation surfaces and building walls will consist of free draining granular backfill with a top size of 1.5 inches and 3 percent or less passing the no. 200 size sieve.
Lean concrete will be used in areas too small to permit placement of engineered fill to provide suitable support for the overlying engineered fill supporting the proposed Category I pipes.
The settlement. of the engineered fill supporting the proposed Category I piping systems was evaluated under dynamic loading conditions by using a synthetic (Bechtell time history with a maximum acceleration of 0.35g to represent the seismic ground motion.
The settlement of the engineered fill due to a seismc event calculated by the applicant was considered negligible.
Diesel Fuel Storage Tanks The proposed diesel fuel storn-tanks will be founded on rock just north of the power block areas for Units I and 2.
The foundation loading is 2000 poundt per square foot.
The staff finds the details of the foundations design shown in Figure 2.5-17e of the Preliminary Safety Analysis Report acceptable.
2.5.3.3 Foundation Treatment for Plant Structures Excavations for proposed Category I structures will be carried out in a controlled manner to minimize damage to the rock foundations.
The staff requires that the applicant complete a test excavation in hard rock, during construction, to demonstratr that specifications and controls for blasting are adequate to assure that the foundation excavations can be Qh 2-45
completed without unnecessary and unacceptable damage to the foundations.
The test excavation should be of sufficient size to include all expected, variations in geologic conditions to be encountered in the excavation during construction.
The staff should be notified when the test excav.
tion is complete and will be available for inspection.
If unsatisfactory results are obtained, the field data will be evaluated by the applicant and the staff to develop suitable controls and criteria for blasting activity.
All excavations wil; be m'qually scaled of loose material and geologically mapped in detail.
The staff will inspect these excavations before mapping is completed.
The staff should be notified at least one week in advance so that an inspection trip may be planned.
Rocks, such as coals and shales which deteriorate and weather rapidly, will be covered with a thin layer of protective concrete within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after exposure at bearing grade.
The foundation excavations will expose zones of coals, shales, and shear zones which will require treatment.
Coal beds range in thickness from a fraction of an inch to about 3.5 feet.
There may also be a few zones of combined coal and carbonaceous siltstone ranging up to 7 to 10 feet in thickness.
The staff requires that all such zones, two feet or greater in width, as measured horizontally on the exposed face, be treated with dental concrete.
This treatment will consist of removal of the weak zone to a depth, below foundation grade, which is at least twice its exposed width.
The excavated weak zone will be sloped on both sides so that it becomes narrower toward the bottom, and the excavation will be cleaned of all loose, soft or unsound rock 5efore being filled with dental concrete.
The analytical justification for this method of treatment will be provided by the applicant in the Final Safety Analysis Report.
2.5.3.4
_ Plant Area Bench Fill About 22 acres of space will be provided on the west side of the proposed site for plant operation.
Existing ground level in this area ranges from 2-46
elevation 415 feet to 355 feet.
Rock material consisting of sound sandstone and siltstone from excavations at the proposed site will be used as fill to establish plant grade (elevation 415) in this area and in the upper reaches of.he Black Creek drainage basin to the north of the proposed plant site. The maximum depth of fill will be approximately 50 feet.
In the proposed plant area around Category I structures and facilities (south of coordinate N 62,400), excavation requirements for the foundation of the bench fill will include removal of all overburden material to dense glacial till (average Standard Penetration values of 100 blows per foot) or bedrock.
Where the overburden thickens to 90 feet in depth in the Black Creek drainage area north of the proposed plant (rorth of coordinate N 62,400), only the surficial organic sofis and the underlying loose glacial drift materials will be removed.
In this area the foundation will be proofrolled; unsatisfactory compressible soils will be removed prior to placing fill.
Black Creek will be diverted to the north of the proposed site; subdrains will be installed in the original Black Creek stream bed and other drainage depressions to permit the free passage of ground water from beneath th9 rock fill areas.
The applicant has assumed that the rock fill in the proposed plant area (south of coordinate N 62,400) will be sufficiently free draining to maintain the normal groundwater level near the base of the fill.
The applicant has established controls restricting the percentage of fines (passing a No. 200 size sieve) permitted in the fill to five percent and has specified that the fill be placed in lift thicknesses not exceeding 36 inches and compacted by a minimum of four passes with a (20,000 pound) vibratory roller.
The optimum lift thickness and compaction effort to achieve an adequate density and to assure drainability is dependent on the actual gradation of the in place rock fill.
The applicant has therefore committed to construction test fills during construction to evaluate these properties.
The in place gradation and density of rocA fill obtained in the field test fills should be evaluated and shown to be satisfactory prior to continuing with fill placement.
The maximum size rock (measured in its maximum dimension) permitted in the fill should be restricted to 2-47
e 2/3 the lift thickness.
Also, every effort should be made to reduce the quantity of coal, shale and carbonaceous siltstone in the rock fill since these materials will deteriorate during handling and placement and degrade drainability of the fill.
The staff requires, and the applicant has so committed. that the first six foot depth of fill not be permitted to contain mee than five percent coal, shales or carbonaceous siltstone since this zone is most critical to foundation drainage.
The applicant will place an eight foot wide engineered transition zone between the engineered fill supporting proposed Category I pipelines and the proposed plant crea rock fill to prevent any tendency for fines in the pipe support fill to erode into the adjacent rock fill.
Lateral earth pressures exerted by the proposed plant area fill against structures will be computed issuming an at-rest earth pressure coefficient of 0.7 to account for the pressures due to compaction of backfill.
The dynamic loading increment of lateral pressure will be computed using the Mononobe-Okabe Methed.
This criteria for lateral soil pressures is acceptable, providing these pressures exceed those calculated from the soil structure interaction analysis.
2.5.4 Seismic Design and Soil Structure Interaction The design basis earthquake is described in Section 2.5.2 of this supplement.
For all rock supported structures, a ground motion with a peak acceleration of 0.35g at the foundation level will be used.
The response spectrum for the design ground motion agrees with Regulatory Guide 1.60.
Dynamic properties of the foundation materials are expected to be be appropriately determined and modeled.
Foundation / structure interaction under seismic loading is taken into consideration using spring interaction analysis techniques described in Section 3.3 of Bechtel Topical Report BE-TOP-4.
This method is appropriate for the foundation conditions of this proposed plant.
2-48
2.5.5 Slope Stability 2.5.5.1 Bacus Hill Bacus Hill is a rock ridge located soutneast of the proposed plant site woich extends from elevation 400 feet at its northern toe near the proposed plant site to elevation 580 feet at its crest.
The southern limit of Bacus Hill is along State Route 20, about 2000 feet south of the proposed plant structures.
The north face of the ridge faces the proposed plant.
The r* dge is composed of sedimentary rock of the Chuckanut Form & tion, the same geologic formation that the proposed plant will be founded on.
Overburden is thin and there are numerous rock outcrops.
The slope of the north side of the ridge toward the proposed plant site flattens from about a 1 vertical (V) on 1 horizontal (H) near its toe to 1 on 3 towards the crest.
The rock bedding dips favorably to the southwest and west, away from the face of the slope which enhances its stability.
There is no evidence of prior landsliding on the north face of Bacus Hill and none would be expected in the existing rock slope before the planned earth and rock cuts except for normal rock spalls due to long-term weathering and erosion.
The overburden could slide if it became saturated or was disturbed at the toe of the slope by spalling rock.
such surficial slides, however, would be small and would not present any hazard to the proposed plant.
See Section 2.5.3.2 for a discussion of precautions for excavations into the toe of this hill.
The dip of the Chuckanut bedding flattens to the south and become less favorably oriented with respect to the soutnern face of Bacus Hill.
However, the strike of the bedding is obliquely oriented dipping toward the west (Fig. 2.5-13 of the Preliminary Safety Analysis Report).
A reconnaissance survey was made of the plant site area by the staff in order to examine existing rock exposures for evidence of slope instability.
Other than movement of small rock masses attributable to road construction activities and normal, expected geologic processes no unusual movement was 2-49
observed.
Numerous Chuckanut Formation exposures, with dips generally ranging from 35' to 60* to the southwest, were examined along 1) State Route 20 at the foot of Bacus Hill, 2) the site access road (Bacus Road),
- 3) the abandoned quarry on Bacus Hill south of Bacus Road, 4) along Wiseman Creek (Powell Creek) approximately 2,000 feet west of proposed Unit 1, and
- 5) in the trenches at the two proposed nuclear reactor locations.
Road construction along Stata Route 20 and Bacus Road has involved rock excavation, blasting, slope undercutting, and ditch excavation.
The predominant dip of the Chuckanut Fo-mation is into the plane of the roadway thus accelerating the movement of small, surface blocks along bedding planes where undercut because of soil and/or rock removal.
The movement of the rock blocks is minor and, where observed is surficial, involving only the lower undercut or undermined toe of the slopes.
Blast effects, involving the movement of small rock masses due to gas overpressure along bedding planes, joints and other openings, was especially common along Bacus Road, the quarry, and in the site trenches.
These are clearly surface phenomena since continuous, undisturbed rock was seen immediately adjacent to the disturbed rock.
Other than small scale surficial movement attributable mainly to erosion, nothing unusual was seen along the good exposures at Wiseman Creek.
No indication of movement was seen in the exposed faces of the gravel pit north of State 20 at Wiseman Creek.
In summary, the staff has seen no evidence within the plant site area indicating the potential for large-scale movement of rock masses and sees no known potential for rock movement affecting the safety of the proposed facilities.
Numerous flow slides of overburden materials (unconsolidated sediments, glacial outwash, and alluvium) have been reported on the south side of Bacus Hill.
Two such slides were reported by Puget Sound Power and Light Company in a summary report of the December 1975 Skagit Valley Flood.
Another report on the same slides was prepared by the %agit County Planning Department, Mount Vernon, Washington.
The staff reviewed these documents and concludes that flow slides of overburden material would not be considered unusual in these materials during period of high rainfall, however, they would not affect the proposed plant safety.
h 2-50
l More recently, Heller (1979a) has reported a number of debris flows and slump flows within the plant site adjacent to State Route 20.
Those factors listed by Heller as contributing toward these slope failures are
- 1) ground water perched at an impermeable boundary and 2) road construction (cutting and filling) (Heller, 1979a) Heller's (1979a) report includes an area within at least 1.5 km of the proposed plant locations and, with the exception of those landslic;es having occurred adjacent to State Route 20, has indicated that the slopes are stable, have not exhibited any landslides in the recent past, and are probably not a significant hazard.
2.5.5.2 Lyman Ridge The geologic structure and stability of Lyman Ridge which is immediately north of the proposed plant site was also evaluated by the applicant.
The toe of the slope is at approximately elevation 500 feet and located about 3000 feet north of the principal plant structures.
From the toe up to the 2000-foot elevation, the slope averages about 20 degrees.
The slope above the 2000-foot elevation, extending to tne crest of the c*dge at a 3450-foot elevation, averages about 15 degrees.
Lyman Ridge is underlain by Shuksan metamorphic rocks.
These rocks are strongly foliated and the foliations dip steeply into the slope.
Any major sliding involving a large mass of bedrock would require shearing of the rock across these foliations and therefore the possibility of large slides appears unlikely.
No evidence of landslide scarps or scars was found by a remote sensing analysis or by a field study conducted by the applicant.
Minor sliding or creep may occur in the colluvium and talus at the toe of this ridge, but the proposed reactors are at least 3000 feet from the toe of the slope and therefore their operation and safety will not be affected if such movement does occur.
2-51 g
BIBLIOGRAPHY" - (Continued from NUREG-0309) 2.5 Seismology, Geology and Geotechnic Engineering Algermissen, S.
T., and S. T. Harding, 1965, The Puget Sound, Washington Earthquake of April 29, 1965:
U.S. Dept. of Commerce - Preliminary Seismology Report.
- Atwater, T., 1970, Implications of Plate Tectonics for the Cenozoic Tectonic Evolution of Western North America:
Geol. Soc. Amer. Bull. v. 81, no. 12.
Balk, R.,1937, Structural Behavior of Igneous Rocks, Geological Society of America,
%moir 5.
Cheney, E. S., 1978, Interim Report on the Seismic and Geologic Hazards to the Proposed Skagit Nuclear Power Site, Sedro Woolley, Washington:
Unpublished Manuscript.
Cof fman, J. L., and c. A. von Hake,1973, Earthquake History of the United States:
U.S. Department of Commerce Publication 41-1.
Coombs, H.
A., 1939, Mt. Baker, A. Cascade Volcano:
Geol. Soc. Americal Bull. v. 50, no. 10.
Coulter, H.
W., H. H. Waldron, and J. F. Devine, '.973, Seismic an(i Geologic Siting Considerations for Nuclear Facilities:
Fifth World Conference on Earthquake Encineering Proceedings, Rome.
Crandell, D. R., and H. H. Waldron,1956, A Recent Volcanic Mudflow of Exceptional rimensions from Mt. Ranier, Washington:
Am. Jour. Sci., v 256, pp. 384-397.
- Note:
Unless otherwise indicated all listc0 references are available in or form public technical libraries or the appropriate university library.
2-52 G<PQ
BIBLIOGRAPHY (Continued)
Crandell, D. R.,1976, Preliminary Assessment of Potentiai Hazards from Fature Volcanic Eruptions in Washington:
U.S. Geol. Survey Misc. Field Studies Map MF-774.
Crosson, R. S.,1972, Small Earthquakes, Structure, and Tectonics of Puget Souna Basin:
Seismol. Soc. America Bull., v. 62, no. 5, pp. 1133-1171.
Crosson, R. S.,1973, Compilation of Earthquake Hypocenters in Western Washington:
Washington Div. Geology and Earth Resources, Inf. Circ. 53.
Crosson, R. S., 1974, Compilation of Earthquake Hypocenters in Western Washington:
Washington Div. Geology and Earth Resources, Inf. Circ. 54.
Crosson, R. S., 1975, Compilation of Earthquake Hypocenters in Western Washington -
1973: Washington Div. Geology and Earth Resources, Inf. Circ. 55.
Crosson, R. S., 1975, Compilation of Earthquake Hypocenters in Western Washington -
1974: Washington Div. Geology and Earth Resources, Inf. Circ. 56.
Dancs, Z. F., et al,1965, Geophysical Investigations of the Southern Puget Sound Area:
Jour. Geophys. Research, v. 77, no.22.
Dickerson, W. R., 1970, Relation of Andesites, Granites, and Carivative Sandstones to Arc-Trench Tectonics, Rev. Geophysics, vol. 8.
Eardley, A.
J., 1962, Structural Geology of North America:
Harper & Row, New York.
Frank, D., M. F. Meier and P. A. Swanson, 1977, Assessment of Increased Thermal Acti-vity at Mount Baker, Washington, March 1975-March 1976, U.S. Geol. Surv. Prof. Paper 1022-A.
Fryxell, R.,1965, Mazama and Glacier Peak Volcanic Ash Layers:
Science, v. 47.
Griggs, F. R.,1922, The Valley of 10,000 Smokes (Alaska):
the Natl. Geog. Soc., 340 p.
2-53
\\15B
BIBLIOGRAPHY (Continued)
Hall, H.
B., and K. L. Othberg, 1974, Thickness of Unconsolidated Sediments Puget Lowland: Washington Div. of Mines and Geology, Geol. Map GM-12.
Hanson, L. G., 1970, The Origin and Development of Moses Coulee and other Scabland Fea-tures on the Waterville Plateau, Washington:
Masters Thesis; University of Washington.
Harding-Lawson Associates, 1975, Gravity Survey, Skagit River Valley, Sedro Woolley, Washington: Appendix 2D, Skagit Nuclear Power Project PSAR.
Harding-Lawson Associates, 1979, Skagit River Valley Gravity Survey-Phase II, Sedro Woolley, Washington:
Appendix 2C, Skagit Nuclear Power Project, Report of Geological Investigations in 1978-1979.
Hayes, D. E., and M. Ewing, 1970, Pacific Boundary Structure, in the Sea, A. E. Maxwell (ed.), Vol. 4, Part II, pp. 29-72.
Heller, P. H., 1978, Pleistocene Geology and Related Landslides in the Lower Skagit and Baker Valleys, North Cascades, Washington:
unpublished M. S. Thesis, Western Washington State University.
Heller, P. L.,1979a, Map Showing Landslides and Relative Slope Stability of Quate-ary Deposits of the Lower Skagit and Baker Valleys, North Cascades, Washington:
U. S. Geol.
Survey Open File Report 79-963.
Heller, P. L. 1979b, Map Showing Surficial Geology of Parts of the Lower Skagit and Baker Valleys, North Cascades, Washington:
U. S. Geol. Survey Open File Report 79-964.
Hodgson, E.
A., 1946, British Columbia Earthquake, June 23, 1946, Jour. Royal Astron.
Soc. of Canada, v. 60.
Hodgson, J. H., and W. G. Milne, 1951, Direction of Faulting in Certain Earthquakes of the North Pacific, Bull. Seis. Soc. Amer., v. 41, no. 3, pp. 221-242.
\\19 2-54
BIBLIOGRAPHY (Continued)
Huntting, M.
T., et al., 1961, Geologic Map of Washington:
Washington Div. of Mines and Geology.
Hyde, J. H., and D. R. Crandell, 1975, Origin and Age of Post glacial Deposits and Assessment of Potential Hazards from Future Eruptions of Mt. Baker, Washington:
U.S. Geol. Survey Open File Report 75-286.
Isacks, B. L., J. Oliver and L. R. Sykes,1968, Seismology and the New Global Tectonics: Jour. Geophys. Research, v. 73, no. 18.
Jenkins, O. P., 1924, Geological Investigations of the Coal Fields of Skagit County, Washington: Washington Div. Geology Bull. 29.
Kaarsberg, R. A., 1967, Magnetic Survey of the Puget Sound Earthquake Zone:
Geo-physics, v. 32.
King, P.
B., 1969, Tectonic Map of North America:
U.S. Geol. Survey.
King, P. B., H. M. Beikman, 1974, Geologic Map of the United States:
U.S. Geol.
Survey.
Livingston, V.
E., Jr., 1969, Geologic History and Rocks and Minerals of Washington, Washington ')epartment of Natural Resources, Division of Mines and Geology, Informa-tion Circular, No. 45.
Livingston, Vaughn E., Jr., 1974, Energy Resources of Washington: Washington Div.
Geology and Earth Resources, Inf. Circ., No. 50.
Lovseth, T. P.,1975, The Devils Mountain Fault Zone, Northwestern Washington:
unpub-lished M. S. Thesis, Univ. of Washington.
MacLeod, N. S., D. L. Tif fin, P. D. Snavely, Jr., and R. G. Currie,1977, Geologic Interpretation of Magnetic and Gravity Anomalies in the Strait of Juan de Fuca:
Canadian Jour. Earth Sci., v. 14, no. 2, pp. 223-238.
g
\\
2-55
BIBLIOGRAPHY (Continued)
- McCleary, J., H. Dohrenwend, L. Cluff, and K. Hansen, 1978, Straight Creek Fault Zone Study: Woodward-Clyde Consultants, prepared for United Engineering and Constructors, Inc.
McKenzie, D., and B. Julian, 1971, Puget Sound, Washington, Earthquakes and the Mantle Structures Beneath the Northwest United States: Geol. Amer. Bull., v. 82, pp. 3519-3524.
Mathews, W. H., J. G. Fyles, and H. W. Masmith, 1960, Postglacial Crustal Movements in Southwestern British Columbia and Adjacent Washington State:
Canadian Jour.
Earth Sci., v. 15, pp.89-117.
Mayers, I. A., and L. C. Bennett, Jr.,1973, Geology of the Straits of Juan de Fuca:
Marine Geology, v. 15, pp.89-117.
Miller, G. M., in press, Western Extent of the Shuskan and Church Mountain Thrust Plates in Whatcomb, Skagit, and Snohomish Counties, Washington:
Northwest Science.
Miller, G. M., and P. Misch, 1963, Early Eocene Angular Unconformity at Western Front of. Northern Cascades, Whatcom County, Washington:
Am. Assoc.
Petroleum Geologist, Bull., v. 47, no. 1.
Milne, W. G., 1965, Seismic Activity in Canada, West of the 113th Meridian 1841-1951:
Publication of the Dominican Observatory, Ottawa, Canada.
- Misch, P., 1979, Geologic Map of the Marblemount Quadrangle, Washington, Geologic Map GM-23:
State of Washington Department of Natural Resources.
Misch, P., 1977(a), Bedrock Geology of the North Cascade in Brown, E. H. and Ellis, R. C. (eds.), jn Geological Excursions in the Pacific Northwest, Geol, Soc. of Amer. Field Guidebook Ann. Mtg., Seattle, Wash., publ. by Dept. of Geol., Western Washington State Univ.
2-56 3
BIBLIOGRAPHY (Continued)
Misch, P. 1977(b), Letter to M. J. Adair dated Oct,ober 23, 1977, Skagit PSAR, Appendix 2G.
Misch, P.,1966, Tectonic Evolution of the Northern Cascades of Washington State:
Canadian Inst. Mining and Metallurgy, Spec. Paper, v. 8.
Misch, P.,1967, Structural Sketch Map of the N:rthast Cascades of *riashir.- on:
unpublished data, Univ. of Washington.
Muller, J. E., and J. A. Jeletsky,1970, Geology of the Upper Cretaceous Nanaimo Group, Vancouver Island and Gulf Islands, British Columbia:
Canada Geol. Survey Paper 69-25.
Mullineaux, D. R.,1974, Pumice and Other Pyroclastic Deposits in Mt. Rainier National Park, Washington:
U.S. Geol. Survey Bull.
1326.
Neumann, F.,1954, Earthquake Intensity and Related Gound Motion University of Washing-ton Press, Seattle, Washington, 77 p.
Norbisrath, H.,1939, Geology of the Mt. Vernon Area:
unpublished B. S. Thesis, Univ.
of Washington.
Preliminary Safety Analysis Report (PSAR),1974, as amended, Skagit Nuclear Power Project, Puget Sound Power and Light Company.
Puget Sound Power and Light Co., 1979, Report of Geological Investigations in 1978-1979, 3 volumes.
Page, B. M.,1939, Geology of a Part of the Chiwaukum Quadrangle, Washington:
unpub-lished Ph.D. Thesis, Stanford University.
Pasmussen, N., 1967, Washington State Earthquakes 1840 Through 1975, Seismol. Soc.
America Bull., v. 57, no. 3.
Regan, D. M., 1968, Structural Geology, An Introduction to Geometrical Techniques, J. Wiley and Sons, Inc., 163 p.
p 2-57
BIBLIOGRAPHY (Continued)
Regan, R. D.,1979, A Critical Evaluation of the Interpretation Report of Aeromagnetic Coverage of the Skagit Nuclear Power Project, Phoenix Corporation, 17 p.
Regan, R. D., 1979, Letter to S. Wastler dated September 18, 1979.
Riddihough, R., and R. D. Hyndman, 1976, Canada's Active Western Margin - The Case for Subduction, Geosciences Canada, v. 3, no. 4.
Riddihough, R., 1977, Lithospheric Plate Interaction of Canada's West Coast During the Last 10 Million Years, Earth Physics Branch Contribution (in preparation).
Riggs, G. B. 1958, Peat Resources of Washington:
Washington Div. Mines and Geology Bull. 44.
Rogers, G. C.,1946, Vancouver Island Earthquake of July 5,1972, Dominican Observa-tory, Earth Sciences Branch, Publication No. 563, Victoria, Canada.
Rogers, W. P.,1970, A Geological and Geophysical Study of the Central Puget Lowland:
Ph.D. Thesis, University of Washington.
Schnabel, P. B., and H. B. Seed, 1973, Accelerations in Rock for Earthquakes in the Western United States:
Seismol.
Soc. America Bull., v. 62, no. 2.
Silver, E. A.,1972, Small Plate Tectonics in the Northeastern Pacific, Seismol. Soc.
America Bull., v. 82.
Smith, S.
W., and W. Foxall, 1976, Geophysical Investigation of the Skagit Valley Earthquakes of 1974-75:
Skagit Nuclear Power Project, PSAR, App. 2M, Univ. of Washington.
Snavely, P. D., Jr., and H. C. Wagoner, 1963, Tectonic and Geologic History of Western Oregon and Washington; Washington Div. Mines and Geology, Rept. Inv. 22.
2-58
\\
BIBLIOGRAPHY (Continued)
Snavely, P. D., Jr. et al.,1974, Preliminary Gravity and Magnetic Maps of the Strait of Juan de Fuca, British Columbia, Canada and Washington, United States:
U.S. Geol.
Survey Open File Report.
Snavely, P. D., Jr., et al.,1976, High Resolution Seismic Profiles Adjacent to Whibey and Fidalgo Islands, Washington:
U.S. Geol. Survey Open File Report 76-187.
Stacey, R. A., and L. E. Stephens, 1969, An Interpretation of Gravity Measurements on the West Coast of Canada:
Canadian Jour.
Earth Sci., v. 6, no. 3.
Stacey, R. A.,1974, Plate Tectonics, Volcanism, and the Lithosphere in British Columbia, Nature, Vol. 250, No. 5462, pp. 133-134.
Sylvester, R. E., L. C. Bennet, Jr., M. A. Sheriff, and R. C. Bostram,1971, The Deter-mination of Active Fault Zones in Puget Sound, Washington, by Means of Continuous Seismic Profiling:
Proceedings of the International Symposium on Engineering Properties of Sea Floor Soils, UNESCO-NSF, Seattle, Washington.
Trifunac, M. D. and A. G. Brady, 1975, On the Correlation of Seismic Intensity Scales with Peaks of Recorded Strong Gound Motion, Bull. Seis. Soc. Amer., vol. 65, pp. 139-162.
U.S Geological Survey, 1978, Aeromagnetic Map of the Bellingham Area, Washington:
U.S. Geol. Survey, Open File Report 78-354.
U.S. Geological Survey,1977, Aeromagnetic Map of Northern and Eastern Parts of the Puget Sound area, Washington:
U.S. Geol. Survey Open File Report 77-14.
Vance, J. A., 1975, Bedrock Geology of San Juan County; in Geology and Water Resources of the San Juan Islands, Washington:
Washington Dept. of Ecology, Water Supply Bull. No. 46.
Vance, J. A., 1977a, The Stratigraphy and Structure of Orcas Island, San Juan Islands, in Geological Excursions in the Pacific Northwest:
Geol. Soc. of Amer. Field Guidebook, Ann.
Mtg., Seattle, Wash. ; publ. by Dept. of Geol., Western Washington State Univ.
C)
BIBLIOGRAPHY (Continued)
Vance, J.
A., 1977b, Fault Studies in the North Cascades; in WPPSS Nuclear Projects Nos. 1 and 4, PSAR, Amendment 23, Subappendix 2RD, p 2RD.5.
Ward, Peter D., letter of Dec. 5,1977 to James F. Devine of the U.S. Geological Survey.
Whetten, J.
T., Zartman, R. E., Blakely, R.
J., and D. L. Jones, Allochthonous Jurassic Ophiolite in Northwest Washington, in press.
Whetten, J. T., D. P. Dethier, and P. R. Carroll,1979, Preliminary Geologic Map of the Clear Lake NE Quadrangle, Skagit County, Washington:
U.S. Geol. Survey Open File Report 79-1468.
Whetten, J. T., Jones, D. L., Cowan, D. S., and Zartman, R. E.,1978, A..s of Mesozoic Terranes in the San Juan Islands, Washington: jn Howell, D. G., and McDougall, K. A.,
Mesozoic Paleography of the Western United States-Pacific Coast Paleography Symposium 2; Pacific Coast Sect., Soc. Econ. Paleont. Mineralogists, Los Angeles, California.
Wickens, A. J. and J. H. Hodgson, 1967, Computer Re-evaluation of Earthquake Mechanism Solutions, 1922-1962, Publication of Dominican Observatory, v. 33, no. 1.
Wilcox, R.
E., 1959, Some Effects of Recent Volcanic Ash Falls with Special Reference to Alaska:
U.S. Geol. Survey Bull. 1028N.
Willis, C.
L., 1953, The Chiwaukum Graben, A Major Structure of Central Washington:
Amer. Jour. Sci., v. 251, pp. 789-797.
2-60