ML19256D658

From kanterella
Jump to navigation Jump to search
Ack Receipt of 760721 & 760727 Submittals of Addl Info. Forwards Addl Request for Info to Complete Evaluation Re Calculation of Radiation Doses to Population within 50-mile Radius of Plant
ML19256D658
Person / Time
Site: Crane 
Issue date: 10/01/1976
From: Jay Collins
Office of Nuclear Reactor Regulation
To: Reid R
Office of Nuclear Reactor Regulation
References
NUDOCS 7910220570
Download: ML19256D658 (3)


Text

~

Dock.:3-M a

a.

a.

OCT 011976 s

D

  • W ff5)lf? BIT l.

Docket No. 50-289 c

a NDORANDUM FOR:

R. Reid, Chief Operating Reactors Branch No. 4, DOR FROM:

J. Collins, Chief Effluent Treatment Systems Branch, DSE

SUBJECT:

ACCEPTANCE REVIEW OF ADDITIONAL APPENDIX I INFORMATION FOR THREE MILE ISLAND NUCLEAR STATION, UNIT hV.1 We have reviewed the additional inforr.ation submitted by the licensee for "Ihree Mile Island Nuclear Station, Unit No.1, dated July 21, 1976, and' July 27, 1976, to meet the requirements of Section V.B of Appendix 1 to 10 CFR Part 50. The Effluent Tre4Onent Systems Branch and the Hydrology-Meteorology Branch find the information satisfactory to begin their evaluation. The Radiological Assessment Branch finds that addi-i' tional information is needed for calculation of radiation doses to the I

population within a.S0-mile radius of the plant, as raquired for the P

s cost-benefit analysis to be performed under Section II.D.

n f

'Ibe Radiological Assessment Branch will need the information noted

(

~

above before they can complete their evaluation. The questions are enclosed.

.3 e

.i g.

u

~

e -ORIGINAL SIGNED BY r

~

JOEN T. COLLINS t

John T. Collins, Chief i

Effluent Treatment Syn.sens Branch Division of Site Safety and Environmental Analysis

Enclosure:

RAB Questions

~

cc:

K. Goller Distribution:

R. Vollmer Docket File 50-289 W. Kroger NRR Reading File l

F. Congel DSE Reading File T. Verdery ETSB Reading File A g ;.

C. Nelson J. T. Collins J. Norris

/

B. Grimes W. Burke 1AC7 7OC P. Stoddart i *t J C LUJ DSE:ETSB$_8 DSE.:ETSB _

Dy ETSB.

.mc.

d.

.k PGStoddab:Lh Bkke ITCollins_

7. 9 10220 EZ O --

10/01/76 10/] /76 10]_/ ]76.__

o,,

  • N.

~ ~ " " " " " ~

\\

'g 1

OCT 011976 REQUEST FOR ADDITIONAL INFORMATION THREE MILE ISLAND NUCLEAR STATION, UNIT NO. 1 DOCKET NO. 50-289 1.

If there is a prior knowledge that the current 50 mile population age distribution may be significantly different from the U.S.

population distribution, then furnish the current age distribution of the 50 mile population (e.g., 0-12, 12-18, >18).

2.

Provide data on annual meat (kg/yr), milk (liters /yr) and truck farming production (kg/yr) and distribution within a 50 mile radius from the reactor. Provide the data by sectors in the same manner indicated in Sections 2.1.3.1 and 2.1.3.2 of R. G. 4.2, Rev. 1.

2 3.

Furnish information on type, quantity and yield (kg/m ) of irrigated crops grown.

4.

Provide information on gra:ing season (give dates), feeding regimes for cattle (such as gra:ing practices, green chop feeding, corn and 2

grass sileage feeding and hay feeding) pasture grass density (kg/m )

2 and yield statistics (kg/m ) for harvested forage crops for beef and dairy cattle feeding.

5.

Determine and indicate in tabular format the present and proiected commercial fish and shellfish catch (in Ibs/yr) from contiguous waters within 50 miles of the plant discharge. Report the catch by total landings and by principal species, indicating the relative amounts used as human food.

Indicate the location of principal fishing areas and ports of landing associated with these contiguous waters and relate these locations to harvest by species.

Indicate the relative amounts consumed locally. Determine and tabulate the present and projected recreational fish and shellfish harvest from these waters in the same format, also indicating principal fishing areas and their yield by species. As above, indicate the relative amounts consumed locally.

Include any harvest and use of seaweed, other aquatic life, or any vegetation used as human food from these waters.

Identify and describe any fish farms or similar aquatu activity within the 50 mile area utilizing water that may reasonably be affected by the power plant discharge.

Indicate the species and production from each of these facilities and indicate the relative amounts consumed locally.

6.

Identify any additional exposure pathways specific to the region around the site which could contribute 10% or more to either indi-vidual or population doses.

1452 286

s

, a 7

Annual Population Doses - Calculate, using the information provided in response to questions 1-6 above and any other necessary supporting data, the annual total-body man-rem and the annual man-thyroid-rem to the population expected to reside in the 50 mile region at the midpoint of plant operation as well as the annual total body man-rem and the annual man-thyroid-rem received by the U.S. population at the same time from all liquid and gaseous exposure pathways. Provide as an appendix to your response a description of the models and assumptions used in these calculations.

1452 287 hN 6*