ML19256D524

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 50-289/73-01 on 730109-11 & Brunner 730207 Transmittal Memo
ML19256D524
Person / Time
Site: Crane Constellation icon.png
Issue date: 02/21/1973
From: James Keppler
US ATOMIC ENERGY COMMISSION (AEC)
To: Schwencer A
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML19256D522 List:
References
NUDOCS 7910180836
Download: ML19256D524 (1)


Text

,

,}

UNITED STATES ATOMIC FNERGY COMMISSION O

'l

'*D l' WASHINGTON, D.C. 20545 February 21, 1973 A. Schwencer, Chief, PWR Branch #4, L METROPOLITAN EDISON COMPANY (THREE MILE ISLAND UNIT 1)

DOCKET N0. 50-289 The enclosed inspection report and transmittal memorandum from our Region I (Newark) Office, relating to an inspection of the subject facility on January 9-11, 1973, are forwarded for infomation.

The enclosures provide information on Metropolitan Edison Company's current plans relating to preoperational testing of the Core Flood System.

In this regard, it should be noted that the test program proposed by Metropolitan Edison Compa1y is considerably less than that which has been perfomed at earlier ct.crent generation PWR facilities.

In an attempt to promote standard testing requirements for all facilities, we have requested our Technical Assistance Branch to develop a proposed position on the acceptable testing that should

{-

be perfomed on Core Flood / Accumulator systems. We plan to forward this proposed position to DL for review and possible adoptian as the Regulatory recomended testing program for such systems at appropriate facilities.

OSM

40. G. Ke p er, Chief, Reactor Testing and Operations Branch Directorate of Regulatory Operations

Enclosure:

R0 Inspection Report No. 50-289/73-01 cc:

L. R. Rogers, RS R. Vollmer, L J. P. O'Reilly, R0:I R. S. Boyd, L (2)

J. Hendrie, L J. G. Davis, RO:II R. C. DeYoung, L (2)

R. W. Houston, L B. H. Grier, R0:II D. J. Skovholt, L (2)

P. A. Morris, R0 N. C. Moseley, R0:IV H. R. Denton, L (2)

H. D. Thornburg, R0 R. W. Smith, R0:V P. Muller, L P.. H. Engelken, R0 E/J. Brunner, RO:I R. Tedesco, L G. W. Reinmuth, R0 dR Central Files 1451 126 72910180 0

-