ML19256D041

From kanterella
Jump to navigation Jump to search
Discusses Vent Valve Insp Requirements at Davis-Besse 1.Test Procedures Tp 200.01 Inadequate.Design Criteria to Be Requested from Licensee
ML19256D041
Person / Time
Site: Crane, Davis Besse  
Issue date: 03/23/1976
From: Martin R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Knop R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19256D037 List:
References
NUDOCS 7910160766
Download: ML19256D041 (2)


Text

..~

UNITCo STATES NUCLEAR REGULATORY COMMISSION REGlo.*J til 799 ROOSEVELT RO AO CLEN ELLYN ILLfl.olS 60137 March 23, 1976 R. C. Knop, Chief, Reactor Projects Section 1 VENT VALVE INSPECTION REQUIREMENTS - DAVIS-BESSE 1 The design and evaluations of the 14 inch diameter internals vent valves utilized in the Davis-Besse Unit I design are described in Sections 4.2.2.2.8, 4.2.2.3, and 4.2.2.4 of the FSAR. The description notes that these valves will be fully open at a differential pressure between the plenum assembly inside the core support shield and the crolant annulus outside the shield of not more than 0.3 psig. The description also notes that these valves should start to open at a differential pressure of 0.15 psig.

(It is noted that Q.4.4.3 of the FSAR indicates that valves will be open at "about 0.5 psig".)

These valves are fitted with lifting lugs which permit their exercising during periods when the vessel is open utilizing long handling tools.

Such periodic exercising is required every 18 months by Technical Specification 4.4.10.1.2.b (Draft Technical Specifications - Davis-Besse Unit 1):

"Each internals vent valve shall be demonstrated OPERABLE at least once every 18 months by visual inspection and manual actuation."

During the review of preoperational test procedure TP 200.01, " Reactor Internals Vent Valve Removal and Replacement, Exercise, and Inspection Test", it was ncted that one of the acceptance criteria for this test called for the opening force (using the exercising tool) to be in the range of 15-25 lbs. with the fully open force to be in the range of 75-100 lbs. This suggests that the ratio of opening to fully open force could be acceptable in the range of 1:3 to 1:7.

Based on the FSAR description and drawings of these valves, it would appear that a ratio of less than 1:2.5 would be appropriate.

Ir. discussing the abova vith the licensee's staff, I was informed that these acceptance criteria were recommended by B&W as being indicative of the experience obtained at other sites and are not directly related to the design criteria for the valves.

In light of the above, I recommend the following steps be taken:

-A

\\4 79101607g

.