ML19256B699

From kanterella
Jump to navigation Jump to search
Forwards IE Bulletin 79-19, Packaging of Low Level Radioactive Waste for Transportation & Burial. Action Required
ML19256B699
Person / Time
Site: Yankee Rowe
Issue date: 08/10/1979
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Groce R
YANKEE ATOMIC ELECTRIC CO.
References
NUDOCS 7908280031
Download: ML19256B699 (1)


Text

[,M'

  • t G ogI9, l

.o UNITED STATES Y2 yy),,<

g NUCLEAR REGULATORY COMMISSION

. j REGION I 0, ' ?*

g 631 PARK AVENL'E

[

KING OF PRUSSIA, PENNSYLVANIA 19406 h,

<./

August 10, 1979 Docket No. 50-29 Yankee Atomic Electric Company ATTN: Mr. Robert H. Groce Licensing Engineer 20 Turnpike Road Westborough, Massachusetts 01581 Gentlemen:

Enclosed is IE Bulletin No. 79-19, which requires action by you with regard to your reactor and/or facility (ies) with an operating license.

Should you have questions regarding this Bulletin or the actions required of you, please contact this office.

Sincerely,

[

Director oyce H. Grier

Enclosures:

1.

IE Bulletin No. 79-19 2.

List of Bulletins Issued in Last Six Months cc w/encls:

H. Autio, Plant Superintendent L. E. Minnick, President 790828cwn

ENCLOSURE 1 UNITEa STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 IE Bulletin No. 79-19 Date: August 10, 1979 Page 1 of 3 PACKAGING OF LOW-LEVEL RADI0 ACTIVE WASTE FOR TRANSPORT AND BURIAL Description of Circumstances:

Low-level radioactive waste is that waste which can be transferred and shipped to one of three waste burial facilities which are located in and licensed by the Agreement States of Nevada South Carolina, and Washington.

On July 10, 1979, the Governors of the three states notified NRC Chainnan Hendrie of the serious and repeated disregard for rules governing the shipments of low-level radioactive wastes to these burial facilities.

Examples of violations of Agreement State, D0T and NRC rules follow:

Improperly packaged uranium fines igniting packaged liquid scintillation vials in combustible waste is believed to have caused a fire and destruction of a truck at the Beatty, Nevada burial facility on May 14, 1979.

On July 2, 1979, three of twelve steel containers shipped to the Beatty burial facility were found to be leaking radioactive material.

The material was described on the bill of lading as being a solid inorganic salt (evaporator concentrates solidified with urea fonnaldehyde) from a reactor facility.

The Governor of the State of Nevada ordered the drums to be shipped out of the state and the burial facility was temporarily closed.

On July 30, the first shipment into the reopened Beatty facility contained free liquid in " solid" material.

The radioactive contents were sand filters used at an insitu leaching process at a uranium mill.

Forty-three shipments with sixty-three deficiencies were observed during the package inspection program between April 10 and July 5,1979, by the Agreement State of South Carolina, at the Barnwll, S.C. burial facility.

The shipments were from reactor, medical, industrial and military facilities.

On June 28, 1979, the Federal Highway Administration issued a Notice of Violation to a reactor facility proposing a $10,000 fine for truck contamination resulting from improper closures on 55-gallon drums of LSA material and for improper loading of the drums on the vehici These are a few examples of shipme DUPLICATE DOCUMENT which did not fully meet NRC, 00T developed to protect the health an Entire document previously three States with licensed burial entered into system u g g / [er:

is not rectified, they may have to three burial sites by violators.

ANO No. of pages: