d' p" "'4,I g j'.

UNITED STATES 4

NUCLEAR REGULATORY COMMISSION

[

) P:

S REGION I k

pc (31 PAR K AVENUE KING OF PRUS$1 A, PENNSYLV ANI A 19406 Docket Nos. 50-277 50-278 Philadelphia Electric Company ATTN:

Mr. S. L. Daltroff Vice President Electric Production 2301 fiarket Street Philadelphia, Pennsylvania 19101 Gentlemen:

The enclosed IE Bulletin 79-10 is forwarded to you for action.

A written response is required.

If you desire additional information regarding this matter, please contact this office.

Sincerely, oyce H. Grier

- Director Enclosures :

1.

IE Bulletin No. 79-in 2.

List of IE Bulletins Issued in Last Twelve Months cc w/encls:

W. T. Ullrich, Station Superintendent Troy B. Conner, Jr., Esquire Eugene J. Bradley, Esquire Raymond L. Hovis, Esquire Warren Rich, Esquire 79 06110/kh Q

UNITED STATES NUCLEAR REGULATORY C0fNISSION OFFICE OF INSPECTION Af4D ENFORCEMEflT WASHIfiGTON, D.C.

20555 IE Bulletin No. 79-10 Date:

May 11, 1979 Page 1 of 2 REQUALIFICATION TRAINING PROGRAM STATISTICS Description of Circumstances:

Because of the apparent failure of the operators at Three Mile Island to recognize certain plant conditions and take appropriate action to effec-tively cool the core and contain fission products after release from the core, the NRC Commissioners are evaluating licensee's requalification training programs.

As one element in this evaluation, the f1RC is in-terested in obtaining statistics about the failure rate on the annual requalification examinations.

The information requested below along with other information will then be used to evaluate the effectiveness of the operator requalificatinn training program.

Action to be Taken by Licensees:

For all power reactor facilities with an operating license.

1.

Provide both the total number and percentage of operators who have failed the annual requalification examination.

2.

Provide the percentage of those operators who take the annual requalification examination and are required to attend lectures on categories of material for which they received a grade of less than 80 percent.

Also provide the total number of supplemental lectures attended (e.g., 3 operators had to attend 2 lectures,1 operator had to attend 3 lectures, etc. ).

3.

Provide both the total number and percentage of operators under the requalification program that participated in accelerated training because they either scored less than 70 percent overall on the annual written examination or had an unsatisfactory performance on the oral examination.

4.

Provide the same informati DUPLICATE DOCUMENT Entire document previously entered into system under:

hk ANO No. of pages: