6 Form NAC-618 U.S. NUCLE AR REGULATORY COMMISSION CERTIFICATE OF CO".*PLIANCE g CFR M For Radioactive M.1:erials Packaaes 1.f a) Ce tif care %weer 1.tbl Revuion No.

1.(cl Pacw :e identifician No.

1.(d ) Pages No. 1.te) Tc 36 No. c.:es i

a

=cac 1

ties /:c26 /9I IF 1

3

2. PRE AM3LE 2.(a)

This cerrd.cate is issued to satisfy Sections 173.':93a.173.394.173.395. and 173.' 06 of the Oepartrwne of Transport 3 tion Ha23rc3us M.sterials Regulations 143 CFR 1701i19 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Depart "ent of Transportation Dangerous Cargoes Regulations (46 CF R 146-1491, as amended.

2.lb)

The packaging and con ents described in item 5 below, meets the safety.tandards set forth in Subpart C of Title 10. Code of Jederal Regulations. Pa t 71. " Packaging of Radioactive Materiats for Transport and Transportation of Radioactive Yaterial Under Certain Conctitions.

2.fc)

This certificate does not relieve t*e consignor from complience with any reouirement of the regulations of the U.S. Department of Transportation or other apphcable regulatory agencies, including the government of any country through or into which the pacnage will be transported,

m. >
3. This certificate is issued on the basis of a safety analysis report of the package design of application-3.(a)

Prepared by (Name and ac fress):

3.(b)

Title and icentification of report or application:

General Electric Company General Electric Company application dated P.O. Box 460 Septemb_er 18, 1968, as supplemented.

Pleasanton, CA 94566 3.(c)

Docket No.

71-$926

4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart O of 10 CFR 71, as applicable, and the condition, specified in item 5 below.
5. Description of Packaging and Authorized Contents, Model Number, Fissile Class. Other Conditions, and References-.

(a) Packaging (1) Model No.:

GE-100 (2) Description A steel encased lead shielded shipping cask.

The cask is a double-walled steel circular cylinder, 20-1/4-inch diameter by 27-1/8-inch high with a central cavity 7-5/8-inch diameter by 10 inches high.

Approximately 5-7/8 inches of lend surround the central cavity.

The cask is equipped with a cavity drain line and lifting device.

Closure is accomplished by a gasketed and bolted steel lead filled plug.

For additional shielding lead, tungsten or uranium 1:ners may be inserted in the cask cavity.

The maximum weight of the packaging is 3,520 pounds.

a 1301 M2

Page 2 - Certificate No. 5926 - Revision No. 3 - Docket No. 71-5926 5.

(a) Packaging (continued)

(3) Drawings The packaging is constructed in accordance with the following General Electric Company Drawings Nos.:

913E390, Rev. 1 612Dl37, Rev. 4 612D139, Rev. 5 693C292, Rev. 5 985C540, Rev. 2 985C575, Rev. 2 693C293, Rev. 3 135C5371, Rev. 2 153F902, Rev. 5 135C5529, Rev. 3 706E594, Rev. 7 153C4270, Rev. 2 (b) Contents (1) Type and form of mat 2 rial By;:roduct and irradiated special nuclear material in solid metal or solid oxide form; or other non-decomposable (at 650 F) solid materiais.

(2) Maximum quantity of material per package Radioac-ive decay heat: 400 watts, ard fissile material:

500 grams U-235 equivalent mass.

(U-235 equivalent mass equals U-235 mass plus 1.66 times U-233 mass plus 1.66 times Pu mass.)

(c)

Fissile Class II Minimum transport index to be shown cn label 5.6 6.

The byproduct and special nuclear material shall be clad, encapsulated or con-tained in a metal encasement in accordance with the statements and representations contained in the General Electric Company's submittal dated June 13, 1969, or in special form (10 CFR 571.4(o)).

7.

At the time of delivery of the loaded package to a carrier fcr transport, the package contents shall be dry and the fissile mz.terial unmoderated (H to X atomic ratio less than 2).

~

1301 043

Page 3 - Certificate No. 5926 - Revision No. 3 - Docket No. 71-5926 3.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

9.

Expiration date:

February 28, 1980.

REFERENCES, General Electric Company application dated September 18, 1968.

Supplements dated: October 25, November 13, and December 19, 1968; June 13, 1969; April 9,1979; and October 8,1979.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION Ci;arles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle ar.d Material Safety Date: OCT 311979 1301 944

.