ML19254D018

From kanterella
Jump to navigation Jump to search
Forwards IE Bulletin 79-24, Frozen Lines. No Action Required
ML19254D018
Person / Time
Site: Atlantic Nuclear Power Plant PSEG icon.png
Issue date: 09/27/1979
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Collier A
OFFSHORE POWER SYSTEMS (SUBS. OF WESTINGHOUSE ELECTRI
References
NUDOCS 7910190293
Download: ML19254D018 (2)


Text

'o UNITED STATES 8

3 NUCLEAR REGULATORY COMMISSION o

E REGION 11 o

a 101 MARIETTA ST N.W., SUITE 3100

'g ATLANTA, GEORGIA 30303 In Reply Refer To:

SEP 2 71979 RII:JP0 (50-437 Offshore Power Systema Attn:

A. R. Collier, President P. O. Box 8000 Jacksonville, Florida 32211 Gentlemen:

The enclosed Bulletin 79-24 is forwarded to you for information.

If you desira additional information regarding this matter, please contact this office.

Sincerely, C'

James P. O'Reilly Director

Enclosure:

IE Bulletin No. 79-24

/

e 1190 089 7910190 s

._-.-..e-_.

4

Accession No. 7908220114 SSINS No:

6820 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 September 27, 1979 IE Bulletin No. 79-24 FROZEN LINES Summary:

On January 3, 1979, an unusual event occurred at Davis-Besse, Unit 1.

The event involved the freezing of the water in a portion of the high pressure coolant injection (HPCI) system recirculation line that is common to both high pressure coolant injection pumps.

The line was not thawed until January 5, 1979, and the event was not reported to NRC until March 12, 1979.

In addition, over the past five years, there have been several events invol.ing frozen instrument and sampling lines.

Description of Circumstances:

The condition was discovered on January 3,1979, while the reactor was operating at approximately 96 percent power. During a monthly surveillance test of the HPCI pumps, there was no flow through the recirculation line from the pump discharge to the Borated Water Storage Tank (BWST).

Investigation revealed that water in a portion of the line exposed to the outside weather was frozen.

This portion of the line to the BWST is common to both HPCI pumps. The line has redundant heat tracing (a heated wire to prevent freezing); it is insulated; and it has a low-temperature alarm system to warn of freezing conditions.

Water in the line froze apparently because of prolonged sub-freezing temperatures and a defect in the insulation.

There was no apparent malfunction of the heat tracing or temperature alarm circuits, although the temperature sensing elements are located in an area not exposed to the coldest temperature conditions.

This recirculation line serves two purposes: One is to provide a flow path for surveillance testing, and the other is to provide a min ium flow path to prevent possible damage to the pump in the event it is operated against a closed discharge valve or a reactor coolant system pressure greater than the maximum discharge pressure of the pump (approximately 1600 psig).

In the initial review of the event on January 3, 1979, the licensee concluded that the pumps were still operable with tl

~

no immediate action was taken to thaw the January 5, 1979, the line was thawed and 1 was*successfully completed.

DUPLICATE DOCUMENT Entire docurent previously entered into syster under:

h[

ANO No. of pages:

.