Jersey Central Power & Light Company y)

. .i h1.n f Madison Avenue at Punch Bowl Road Mornstown, New Jersey 07960 (201)455-8200 September 21, 1979 Director of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, DC 20555

Dear Sir:

Subject:

Oyster Creek Nuclear Generating Station Docket No. 50-219 Relicf Valves In response to Mr. Brian K. Grimes' letter of July 16, 1979 on the subject of safety / relief valves, Oyster Creek does not utilize Target Rock valves. We will therefore as directed disregard the enclosure to that letter.

Very truly yours, Ivan R. Finfr ,J Vice Preside o la 1046 258 7 9 09 '? 7 9 R f Jersey centrai P=r nyt cey is a Meer e tne ner Puse utees System q