Forwards Executive Summary,Tmi Liquid & Gaseous Releases Vs Tech Specs as Result of Incident on 790328
ML19254B222
Person / Time
Site: Crane  
Issue date: 08/12/1979
From: Porter S
PORTER CONSULTANTS, INC.
To: Jay Collins
Office of Nuclear Reactor Regulation
Shared Package
ML19254B223 List:
References
NUDOCS 7909240597
Download: ML19254B222 (1)


Text

sea / POR Porter Gertz Cenouttants Inc.

fo-J2 0 76 RITTEedHoVSE PLACE A M OMC M E, P A.19003 215 496-5353 August 12, 1979 August 18, 1979 REV: 1 Subj ect: Effluent Releases from TMI Units 1 and 2 For First and Second Quarter 1979 To:

R. C. Arnold

~.

J. G. Herbein J. R. Thorpe J. E. Mudge L. W. Harding J. B. Logan G. P. Miller B. C. Rusche J. J. Barton

~

J. L. Seelinger L. J. Landry -

-'J. T.iCollins, NRR,?NRC4 1.

Enclosed is an Executive Summary cr TMI Units x and ? Liquid and Caseous Releases vs Techn!&al Specifications.ss a Resc'e of the Incident of March 28, 1979 2.

Tables 1-8 provides additions t data for liquid discharges to the Susquehanna River.

bis

,e W Syd W. Porter, Jr. C.H.P.

l'f Head, Effluent /Enviromental Assesment Group e

O O*

992 309 4

~

1909240 '

'