ML19254A769

From kanterella
Jump to navigation Jump to search
Forwards IE Bulletin 79-18, Audibility Problems Encountered on Evacuation of Personnel from High Noise Areas. No Action Required
ML19254A769
Person / Time
Site: Marble Hill
Issue date: 08/07/1979
From: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Coughlin J
PSI ENERGY, INC. A/K/A PUBLIC SERVICE CO. OF INDIANA
References
NUDOCS 7908150379
Download: ML19254A769 (1)


Text

[gauc o

'o, UNITED STATES

}[Q

'g NUCLEAR REGULATORY COMMISSION g.7 c

REGION lli b

799 ROOSEVELT ROAD

' k.' [o o,

GLEN E LLYN, lLLINOIS 60137 Docket No. 50-546 Docket No. 50-547 Public Service of Indiana ATTN:

Dr. James Coughlin Vice President, Nuclear 1000 East Main Street Plainfield, IN 46168 Gentlemen:

The enclosed IE Bulletin No. 79-18 is forwarded to you for information.

No written response is required.

If you desire additional information regarding this matter, please contact this office.

Sincerely, 0

$/

1 James G. Keppler/

Director

Enclosure:

IE Bulletin No. 79-18 cc w/ encl:

Mr. R. M. Brown, Construction Project Superintendent Central Files Director, hTR/DPM Director, NRR/ DOR PDR Local PDR NSIC TIC LeBoeuf, Lamb, Leiby & MacRae 7 908150 377. a

Accessions No: 7908030403 SSINS No: 6820 UNITED STATES NUCLEAR REGULATORY COMMISSION 0FFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 August 7, 1979 IE Bulletin No. 79-18 AUDIBILITY FROBLEMS ENCOUhTERED ON EVACUATION OF PERSONNEL FROM BIGH-AREAS Description of Circumstances:

In January 1979, a number of licensee personnel were engaged in routine activities in the auxiliary building at the Florida Power Corporation, Crystal River Unit 3 nuclear plant.

While these individuals were working in the auxiliary building, in a high-noise (fan) area, an unplanned release of radio-active noble gases was detected by building monitors within the auxiliary building at concentrations which caused the licensee to initiate the facility emergency plan auxiliary building evacuation procedure.

The facility Emer-gency Officer (Shift Supervisor) assessed the monitor readings and initiated an auxiliary building evacuation. The evacuation announcement, made over the licensee's PA system, was not heard by the personnel working in the high-noise Licensee personnel did evacuate the auxiliary building upon observing aleu.

that other personnel had left, if an evacuation had been initiated.and after calling the control room to inquire During these occurrences, licensee personnel were not exposed to quantities of radionuclides above regulatory guidance.

However, the potential existed for inadvertent unnecessary exposure of individuals to radioactive materials.

Subsequent to the NRC followup inspection of this occurrence, Florida Power Corporation initiated an assessment of this situation and performed an engineering evaluation and identified several plant areas where the annun-ciator system needed audibility improvement. The licensee has installed a new auxiliary building evacuation tone signal and may add visual alarm indi-cators in areas of very high-noise.

Action to be Taken by the Licensees:

For all power reactor facilities with an operating license:

1.

Ostermine whether current alarm systems and evacuation announcement systems are clearly audible or visible throughout all plant areas with emphasis on high-noise areas. Determination in high noise areas must be made with the maximum anticipated noise level.

DUPLICATE DOCUMENT Entire document previously entered into system under:

ANO 7909030 40 b No. of pages:

S

..