O Appendix A NOTICE OF VIOLATION Ptlton rasteel, Inc.

License No. 48-02669-02 As a result of the inspection conducted on January 6, 1981, and in accordance with the Interim Enforcement Policy, 45 FR 66754 (October 7, 1980), the following violation was identified:

10 CFR 34.33(c) requires pocket dosimeters be checked at periods not to exceed one year for correct response to radiation.

Contrary to the above, no checks of your pocket dosimeters were performed during 1980.

This is a Severity Level V violation (Supplement VII).

Pursuant to the provisions of 10 CFR 2.201, you are required to submit to this office within twenty-five days of the date of this Notice a written statement or explanation in reply, including for each item of noncompliance:

(1) corrective action taken and the results achieved; (2) corrective action to be taken to avoid further noncompliance; and (3) the date when full com-pliance will be achieved.

Under the authority of Section 182 of the Atomic Energy Act of 1954, as amended, this response shall be submitted under oath or af firmation.

dated W. L. Fisher, Acting Chief Fuel Facility and Materials Safety Branch 5103000179