Forwards IE Bulletin 79-13,Revision 1, Cracking in Feedwater Sys Piping. No Action Required
ML19249E748
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 08/30/1979
From: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Gary R
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
References
NUDOCS 7910020330
Download: ML19249E748 (1)


Text

/

C km ancu

'o UNITED STATES

' E [^').7

'g g

NUCLEAR REGULATORY COMMISSION r, ' \\

cE f1EGIOiv IV

[

611 RYAN PLAZA DRIVE, SUITE 1000

\\ [be t, -

t

,d AR LINGToiv, T E X AS 76012 August 30, 1979 In Reply Refer To:

RIV Docket Nos.

50-445/IE Bulletin No. 79-13, Revision 1 50-446/IE Bulletin No. 79-13, Revision 1 Texas Utilities Generating Company ATTN:

Mr. R, J. Gary, Executive Vice President and General Manager 2001 Bryan Tower Dallas, Texas 75201 Centlemen:

IE Bulletin 79 -13 was originally sent to you tor action on June 27, 1979.

The enclosed IE Bulletin 79-13, Revision 1 is forwarded to you for information.

No written response is required. This Revision is being dispatclied for action to the additional Utilities, listed in Enclosure 3, who are applicants for operating licenses.

If you desire additional information regarding this matter, please contact this office.

Sincerely,

.tj k Karl V. Sey'fri Director I/

Enclosures:

1.

IE Bulletin No. 79-13, Revision 1 2.

List of IE Bulletins Issued in Last Six Months 3.

Designated Applicants for Operating Licensea 1072 L2 f7 7910029 33 0

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 IE Bulletin No. 79-13 Revision 1 Date: August 30, 1979 Page 1 of 4 CRACKING IN FEEDWATER SYSTEM PIPING Description of Circumstances:

On May 20, 1979, Indiana and Michigan Power Company notified the NRC of cracking in two feedwater lines at their D. C. Cook Unit 2 facili' J.

The cracking was discovered.following a shutdown on May 19 to investigate leakage inside containment.

Leaking circumferential cracks were identified in the 16-inch feedwacer elbows adjacent to two steam generator nozzle elbow welds.

Subsequent radiograpaic examination revealed crack indications in all eight steam generator feedwater lines at this location on both Units 1 and 2.

On May 25, 1979, a letter was sent to all PWR licensees by the Office of Nuclear Reactor Regulation which informed licensees of the D. C. Cook failures and requested specific information on feedwater system design, fabrication, inspection and operat.ing histories.

To further explore the generic nature of the cracking problem, the Office of Inspection and Enforcement requested licensees of PWR plants in current outages to immediately conduct volumetric exam' nation of certain feedwater piping welds.

As a result of these actions, several other licensees with Westinghouse steam generators reported crack indications. Southern California Edison reported on June 5,1979, that radiographic examination revealed indications of cracking in feedwater nozzle-to piping welds on two of three steam generators of San Onofre Unit 1.

On June 15, 1979, Carolina Power and Light reported that radiography showed crack indications in similar locations at their H. B.

Robinson Unit 2.

Duquesne Power and Light confirmed on June 18, 1979, that radiography has shown cracking in their Beaver Valley Unit 1 feedwater piping to vessel nozzle weld.

Public Service Electric and Gas Company reported on June 20, 1979, that Salem Unit 1 also has crack indications. Wisconsin Public Service Company decided on June 20, 1979, to cut out a feedwater nozzle-to pipe weld which contained questionable indication, for metallurgical examination.

As of June 22, 1979, and since May 25, 1979, seven other PWR facilities have inspected the feedwater nozzle-to pipe welds without finding cracking indications.

m-m-wmq~ m m.

rw-The feedwater nozzle-to pipe configuratV '

are shown on the attached Figures 1 andl DUPLICATE DOCUMENT weld joint detail showing the principalj g

Onofre are shown on the attached Figurej Entire document previously entered i into system under:

7,90SAAo/W l".

nNO No. of pages:

N l o l,l, w,,

a kins b 6.wwe bw.c R9-_

~ ~ bkh.-.

DESIGNATED APPLICANTS FOR OPERATING LICENSES Salem 2 North Anna 2 Diablo Canyon i a 2 Sequoyah 1 McGuire 1 San Onofre 2 Summer Watts Bar 1 & 2 e

b

\\ ol? =^