ML19249E742

From kanterella
Jump to navigation Jump to search
Forwards IE Bulletin 79-13,Revision 1, Cracking in Feedwater Sys Piping. No Action Required
ML19249E742
Person / Time
Site: South Texas  
Issue date: 08/30/1979
From: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Eric Turner
HOUSTON LIGHTING & POWER CO.
References
NUDOCS 7910020319
Download: ML19249E742 (1)


Text

~/./ 6 p # recoq%

s UNITED STATES

  • E y'O;..-. (

g NUCLEAR REGULATORY COMMISSION G 4\\

o, %[\\ *~[ /c'[

611 RYAN PLAZA DRIVE, SUITE 1000 E

REGION IV

  1. 't,

,o*

ARLINGTON TEXAS 76012 August 30, 1979 In Reply Refer To:

RIV Docket Nos. 50-498/IE Bulletin No. 79-13, Revision 1 50-499/IE Bulletin No. 79-13, Revision 1 Houston Lighting & Power Company ATTN:

Mr. E. A. Turner, Vice President Power Plant Construction and Technical Services Post Office Box 1700 Houston, Texas 77001 Gentlemen:

IE Bulletin 79-13 was originally sent to you for action on June 27, 1979.

The enclosed IE Bulletin 79-13, Revision 1 is forwarded to you for information.

No written response is required. This Revision is being dispatched for action to the additional Utilities, listed in Enclosure 3, who are applicants for operating licenses.

If you desire additional information regarding this matter, please contact this office.

Sincerely,

[

2 l

'Karl. Sey rit Director

/

Enclosures:

1.

IE Bulletin No. 79-13, Revision 1 2.

List of IE Bulletins Issued in Last Six Months 3.

Designated Applicants for Operating Licenses C]?\\

.,.3

} O l t-7910020 4

UNITED STATE 3 NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 IE Bulletin No. 79-13 Revision 1 Date: August 30, 1979 Page 1 of 4 CRACKING IN FEEDWATER SYSTEM PIPING Description of Circumstances:

On May 20, 1979, Indiana and Michigan Power Company notified the NRC of cracking in two feedwater lines at their D. C. Cook Unit 2 facility. The cracking was discovered following a shutdown on May 19 to investigate leakage inside containment.

Leaking circumferential cracks were identified in the 16-inch feedwater elbows adjacent to two steam generator nozzle elbow welds.

Subsequent radiographic examination revealed crack indications in all eight steam generator feedwater lines at this location on both Units 1 and 2..

On May 25, 1979, a letter was sent to all PWR licensees by the Office of Nuclear Reactor Regulation which informed licensees of the D. C. Cook failures and requested specific information on feedwater system design, fabrication, inspection and operating histories. To further explore the generic nature of the cracking problem, the Office of Inspection and Enforcement requested licensees of PWR plants in current outages to immediately conduct volumetric examination of certain feedwater piping welds.

As a result of these actions, several other licensees with Westinghouse steam generators reported crack indications. Southern California Edison reported on June 5, 1979, that radiographic examination revealed indications of cracking in feedwater nozzle-to piping welds on two of three steam generators of San Onofre Unit 1.

On June 15, 1979, Carolina Power and Light reported that radiography showed crack indications in similar locations at their H. B.

Robinson Unit 2.

Duquesne Power and Light confirmed on June 18, 1979, that radiggraphy has shown cracking in their Beaver Valley Unit I feedwater piping to vessel nozzle weld.

Public Service Electric and Gas Company reported on June 20, 1979, that Salem Unit 1 also has crack indications. Wisconsin Public Service Company decided on June 20, 1979, to cut out a feedwater nozzle-to pipe veld which contained questionable indication, for metallurgical examination.

As of June 22, 1979. and since May 25, 1979, seven other PWR facilities have inspected the feedwater nozzle-to pipe welds without finding cracking indications.

The feedwater nozzle-to pipe configura C M " " N. T N "Si are shown on the attached Figures 1 an!i weld joint detail showing the principaq DUPLICATE DOCUMENT Onofre are shown on the attached Figur Entire document previously entered into system under:

ANo 790F2.RO/0/