Seismic Risk Analysis for Atomics Intl Nuclear Matls Development Facility,Santa Susana,Ca
ML19249A330
Person / Time
Site: 07000025
Issue date: 12/29/1978
From:
TERA CORP.
To:
Shared Package
ML19249A329 List:
References
REF-PROJ-M-3 NUDOCS 7908220084
Download: ML19249A330 (48)


Text

'a SEISMIC RISK ANALYSIS FOR THE ATOMICS NTERNATIONAL NUCLEAR MATERIALS DEVELOPMENT FACILITY sat'TA SUSANA, CALIFORNI A suo me: to LAWRENCE LIVERMORE LABORATORY F.O. Box 808 Livermore, California 94550 Attention: Mr. Don Bernreuter Project Manager TERA CORPORATION Teknekron Energy Resource Analysts 2150 Shattuck Avenue Berkeley. California 94704 415 845 5200 Decernber 29,1978 79082200 N

TABLE OF CONTENTS Section Pooe

1.0 INTRODUCTION

AND SUMM ARY...............................

1-1 2.0 SEISMIC RISK METHODOLOGY.................................

2-1 2.1 Thuory..................................................

2-2 3.0 GEOLOGY...................................................

3-l 3.I R egional G eol ogy.........................................

3-!

3.2 S i t e G eol og y.............................................

3-5 3.3 G eologi c Haz ards.........................................

3-7 4.0 SEISMOLOGY.................................................

4-l 5.0 C ALCULATIONS AND RESULTS................................

5-I 5.I Input....................................................

5-1 5.2 Results..................................................

5-9 5.3 R esponse S pe ct rum.......................................

5-10 6.0 B I BL I OGR APH Y...............................................

6-1 844

=

TERA CORPORATION

l.0 INTRODUCTION NO

SUMMARY

In this report, TERA Corporation presents the results of a detailed seismic risk analysis of the Nuclear Materials Development Focility (NMDF) operated by Atomics internatior,al at Santo Susana, California.

This report is one part of a larger effort being directed by the U.S. Nuclear Regulatory Commission.

The NRC's objective in commissioning the overall report is to essess and improve, to the extent practicable, the ability of this f acility to withstand adverse natural phenomeno without loss of copocity. This report focuses en earthquakes; the other natural hazards, being oddressed in separate reports, are severe weather (strong winds and tornados) and floods. The overall analysis will provide o mean-centered assessment of the consequences of an accident resulting from any of these natural phenomeno. The assessment will express a quantitative probobilistic measure of the potential structural demoge and the release function. It will also provide a probabilistic estimate of the resulting dose of radioactivity to the public.

To ensure credible results, very sophisticated but well-occepted techniques were employed in this component of the project, an analysis of the seismic hozord.

The calculational method we used, which is based on Cornell's work (1968), has been p.eviously applied to safety evaluations of major projects.

The historical seismic record was established offer a review of available litera-ture, consultation with operators of local seismic arrays and examination of oppropriate seismic data bases including the USGS, California Institute of Tech-nology and NElS data bases.

The resulting seismic record, covering the period 1769-1977, was used to identify all possible sources of seismicity that could affect the site. Inadequacies and incompleteness in this record were explicitly considered in this definition of source regions cnd their activity rates. Where there were uncertainties, we assigned subjective probabilities to the spcn of uncertainty.

M 4 l-l TERACORPORATION

The acceleration attenuation relation used in the molysis was developed based on a complete re-evoluotion of oil relevant strong motion dato, with particular ottention directed to the near-field environment.

To guarantee use of the best available calculational methods and input, the entire project vcos reviewed by two seismologists with particular expertise in the local and regional seismology and tectonic setting:

Dr. John G. Anderson University of Southern California Professor Stewart W. Smith, University of Washington The results of our cnolysis, which include estimates of the uncertainty, are presented in Figure I-l.

Our best estimate curve indicates that the Atomics internationo! Focility will experience 30 percent g with a return period of 55 yeors and 60 perce t g with a retum period of 750 years. The curves on either side of our best estimates represent roughly the one standard deviation confidence limits about this best estimate.

These curves provide the seismic design basis for the NMDF in terms of peak ground acceleration. For those structures and equipment that could experience structural amplification, we recommend application of the mean rock response spectrum contained in WASH 1255.

TERACORPORATION

0 10 l

4 i

i

/

3 iO 7

/

/,

s.

1 I

/ I

/

/.-

I I

I

/

l/

/

l l

I

/

/

/

I

/1/ /

l i

f I

5

~

6 2

l

+ 0 10 5

1 I i /

f.

i g

i

/

i/

/i i

2 I

/

/

/

I i

5 i

/

fi f

i i

9 1

1/ /

/

I i

I

// /

I l

I 10 i

i 1

i i

BEST i

i ESTIMATE i

0 10 0

10 20 30 40 50 60 70

%g b

FIGURE l-I RETURN PERIOD - ACCELERATION FOR THE NMDF TERA CORPORATION

2.0 SEISMIC RISK METHODOLOGY A seismic risk analysis is only as credible os the risk onelysis methodology and the input to it. This section presents the basis for our selection of a probabilistic Poisson model for the risk assessment at the Nuclear Materials Development Facility.

There ace generally two distinctly different approaches to seismic risk analysis:

probabilistic and deterministic.

Using the deterministic approach, the analyst judgmentally decides that on earthquake of a given magnitude or intensity occurs at a specific location. He then attenuates the ground motion from the earthquake source to the site and determines the effects of that quake. The problem in using this approach is that it is difficult to define the margin of safety or the degree of conservatism in the resulting design parameters. Analysts are often asked to provide information on the " maximum possible" or "most probable" earthquakes for design purposes, but the deterministic opproach does not ecsily provide those answers.

A probabilistic approach, on the other hand, quantifies the uncertainty in the number, size, and location of possible future earthquakes and allows on analyst to present the trade-off between more costly designs or retrofits and the economic or social impact of a foi!vre. Because the product of a probabilistic approach is a measure of the scismic risk expressed in terms of return period, this trade-off con easily be quantified.

Although the probabilistic opproach requires significantly more effort than the deterministic approach, it has the following advantages:

e it quantifies the risk in terms of return period; e

It rigorously incorporates the complete historical seismic record; it can incorporate the judgment and experience of the hkk e

analyst; 2-l TERA CORPORATION

it accounts for incomplete knowledge regarding the loco-e tion of faults; it has the flexibility to ossess the risk at the site in terms e

of spectral acceleration, velocity, displacement, or earth-quake intensity.

The credibility of the probabilistic approach hos been established through de-toiled technical review of its application to several important projects and creas.

Recent cpplications include assessments of the seismic risk in Boston (Cornell and Merz,1974), in the San Francisco Boy Area (Vogliente,1973), in the Puget Sound Area (Stepp,1974) and continental' United States (Algermissen and Perkins, 1976). Results of these studies have been applied to, among other creas:

Development of long-range earthquake engineering re-e search goals; e

Planning decisior.s for urbon development; e

Environmental hazards associated with the milling of uranium; ord Design considerations for radioactive waste repositories.

e This diversity af application demonstrates the :,herent 'iibility of the risk assessment approach.

2.1 THEORY The risk calculations con be" fundamentally represented by the total probability theorem P [A]

P [A/m cnd r] f I*)I (r) dmdr

=

M R

where P indicates probability, A is the event whose probability is sought, and M and R ore continuous, independent random variables which influence A.

The probability that A will occur con be calculated by multiplying the conditional probability of A, giver, events m cnd r, tir.es the probobilities of m cnd r, and integrating over all possible values of ru m d r.

844 2-2 TERACORPORATION

In our ossessment of the NMDF, A will be taken as maximum acceleration and therefore P [ A/m and r ]

will be derived from dato relating peck occeleration to epicentrol distance and earthquake mognitude. Of ten known as attenuotion data, these dato are usually lognormally distributed arodnd a mean relationship of the form (McGuire,1977o).

A = C, e (R+r,) 3 2

The distribution on earthquake mognitude, f (m), con rermly be derived from on g

actual or postulated frequency relationship of the form log N = o-bM where N is the number of earthquakes having mognitude greater than M, and o and b are constants chorocteristic of the porticular source region under con-sideration. It follows (Cornell,1968) that f con be derived from the cumulative g

distribution function, F, which has the form, g

M = k (i.e O M)

F where k is a normalizing cor.stant and 8 = binl0.

The distribution on distance, f (r), depends on the geometry of the problem R

under consideration.

For simple geometries, the distributions con of ten be integrated analytically. Realistic geometries however, re. quire r.umerical eval-votion of the integro!. A very versatile computer program has been developed by Anderson and Trifunce (1978) that incorporates the theory presented above with a numerical integration scheme that allows for evoluotion of very complex source-site geometries.

2-3 TERACORPORATION

The overall approach to performing seismic risk assessment by this theory is summarized below. First, the historical earthquake record and local attenuation dato are combined with the experience of the analyst to produce the functional relationships applicable '.. the area under consideration. The source regions are divided into circular sectors and proportional seismicity is allocated to eacn sector. The total expected number of evcnts cousing maximum occelerations at the site greater than a porticular test acceleration is obtained by summing the events from each sector within each source region. The risk associated with this test acceleration is then ec'culated using the conventional ossumption that earthquakes have o Poisson distribution in time. It then follows inct the retum period is simply the reciprocol of tne risk.

In recognition of the uncertainties in any seismological analysis, we test the sensitivity of results to variations, corresponding to the uncertainty, in key parameters. The results are then combined by assigning subjective probabilities to the range of variations and weighting the results acce.dingly. The final synthesized estimate of the seismic risk con be considered a Boyesion estimate (Cornell and Merz,1974).

i 844

-e 2-4

?

TERA CORPORATION s

3.0 GEOLOGY 3.1 REGIONAL GEOLOGY 3.i.1

SUMMARY

The Atomics International Nuclear Materials Development Facility is located in the Los Angeles crea of the Transverse Range Geomorphic Province of California. The crea is within the Simi ! ulls, opproximately 10 miles west of Conogo:

k, California.

The geology of the southern Ventura County part of the province is dominated by the Ventura basin, which extends westerly u. der the present Pacific Ocean. This is on east-trending region that has been down-warped and in which has been deposited a great thickness of sediments during the last 60 to 75 million years.

The sedimentory rocks have been tectovicll,' defe"aed nd partly uplifted to form hills and mountains.

3.1.2 REGIONAL PHYSIOGRAPHY Regionclly, the study crea is situated on o plateau named Burro Flats within the Simi Hills, isolated by distance and rugged terrain from densely pooulated creas.

A semi-arid region, the low altitude and ocean influence results in a relatively mild climate throughout the year.

The Venturo basin is on elongate sedimentary trough which, together with its deformed structures, trends approximately east-west. Most of the southeastern port of the Ventura basin is in the Santo Clara watershed. Old high-level erosion surfaces, some more than 3,000 feet in altitude, and younger, topographically lower river-terroce surfaces and deposits are conspicuous (Winterer and Durham,

!962).

844

'~-

3-l TERA CORPORATION

3.l.3 GEOLOGY A great thickness of sediments has been deposited in the Ventura basin, mostly by the sea which has since receded from the eastern part of the bosin. The resultant sedimentary rocks have been tectonically deformed and partly uplif ted to form hills and mountains. Sediment is still being deposited clong intervening volleys and canyons and into the sea, principally from the Santa Clara and Ventura Rivers. The Santa Clara River is a remnant of what was probably a much greater river system, whose earlier delta is preserved as the sediments of early to late Quaternary age underlying large creas in the eastern and central parts of the county, and beneath the Oxnard Plain (Weber, et al.,1973).

The Venturo basin is a narrow trough, filled with sedimentary rocks, whose axis coincides approximately with the Santa Clara River valley and the Santa Barbara Channel. This, arrow troughlike form did not begin to develop until near the beginning of the Miocene epoch (Winterer and Durham,1962). Near the south margin of the Ventura basin the thick section of upper Cenozoir rocks has been thrust southward along the Santa Susana fault toward the older rocks of the Simi Hills. The southeastward-trending San Gabriel fault transects the northeastern part of the basin. Dissimilar facies in the pre-Pliocene rocks on opposite sides of this fault indicate a long period of continued movement. The major folds and faults between the San Gabriel and Santa Susana faults trend northwestward; most of the faults are southward dipping reverse faults.

Much of the folding and faulting has been due to compression from ror*h to south during the lost five en one million years (Weber, et al.,1973). This folding and faulting has resulted ir the Son Cayetano, Oak Ridge, Sen;a Jasona and other fault zones.

3.1.4 REGIONAL STRATIGRAPHY The sedimentary rocks in the crea range from the Cretaceous " Chico Formation" to Recent. Maximum thickness of the Chico Formation ranges to 5,500 feet in the Simi Hills-Sonto Susana Mountains regions.

The overlying Tertiary and Quaternary deposits include those of landslide, steam, and lacustrine origin.

84k 3-2 TERA CORPORATION

3.1.5 REGIONAL STP ICTUaE Major Slding and faultr she area took riace during the last one to five million ya, t id was due to north to south '.ompression. Fault zones developed include the San Andreas, the Santa Ynez, the Newport-Inglewood, the San Gabriel, and the ivialibu Coast faults. Each of these faults is h-icfly reviewed below.

San Andreas Fault. This active master fault traverses 800 miles oi ~ stern California, and passes within 34 miles of the Burro Flats site. It has been the locus of at least one great earthquake during historic time, and present evaluations suggest that the most likely plan Mr the next earthquake is the fault segment that generated the Fort Tejon earthquake of 1857, which lies opposite the Burro Flats site. Surface rupture has accompanied the larger and some of the smaller historic earthquakes on the fault. Marked topographic evidence of fault disruption of the ground surface testifies to persistence of this activity back at least into the recent past, and geologic evidence indicates persistence of right slip for many tens of millions of years.

Geodetic measurements reveal that deformation across the fault system is continuing today, indicating that future earthquakes can be expected.

Santo Ynez Fault. This is a major active fault in California that trends eastward for about 82 miles along the north margin of the Transverse Ranges, and approaches within 30 miles of the Burro Flats site at its eastern end. It has a total displacement measurable in miles, and bears evidence of quite youthful movement.

The fault is the site of fairly consistent left-lateral stream offsets, and the;e are reports of furrowing of the ground surface, ponding of slope wash, and vague indications that in one place terrace deposits may be faulted. Thus it must be concluded that the Santa Ynez fault has been active in late Quaternary time, and probably in Holocene time as well.

Like the San Andreas fault, the Santa Ynez fault is a steep fault with a relatively straight trace and is marked by a zone of shearing as wide as 1,500 feet and Mk 3-3 TERA CORPORATION

numerous elongate fault slivers. Displacement across the fault is probably at least several miles, with significant components of both dip-slip and lef tlateral strike-slip.

Newport-Inglewood Zonc.. This active structural zone, probably a part of the San Ant -as fault system, has undergone major right slip and seems to separate continental from Franciscon basement at depth. From o point about 20 miles southeast of the Burro Flats site it extends southeastward for 45 miles across the Los Angeles Bosin, and continues on for an unknown distance beneath the Pacific Ocean.

Abundant evidence of late Quaternary displacement exists along the zone and it is considered the source of the 1933 Long Beach earthquake.

The zone consists of a complex of interrelated faults and folds in a sedimentory section about 12,000 feet thick, which extends down into basement rock as a relatively simp:e fault zone.

The Newport-Inglewood zone does not extend northwestward beyond the Malibu Coast fault, but rather merges with that fault to fmm o coherent structural system.

This system has clicwed Franciscon terrain of the continental borderland to move northwestward along the Newport-Inglewood zone and down beneath the leading edge of the Transverse Ranges along the Mnlibu Coast fault.

Son Gabriel Fault. This is a major fault in the San Andreas fault system that has undergone 20 to 30 miles of right slip. The fault is 74 miles long (including its southern bronch), and posses within 16 miles of the Burro Flats site. Opinion differs over the present tectonic vitality of the Son Gabriel fault. Richter (1958) and others have concluded that this fault is inactive.

Molibu Coast Fault. As a member of the Santo Monico fault system, this north-dipping fault forms part of the south margin of the Transverse Ranges structural province, and in concert with the right-lateral Newport-Inglewood zone, it has undergone thousands of feet of thrust movement.

The Malibu Coast fault extends westward for 30 miles from the Newport-Inglewood zone along the south margin of the Santa Monica Mountains, passes within 13 miles of the Burro Flots

^

f

~

3-4 TERA CORPORATION

site, and may continue westward beneath the Pacific Ocean for 15 or more miles.

Several lines of evidence suggest that the fault has potential as a future generator of large earthquakes.

The Malibu Coast fault is a north-dipping thrust that separates sedimentary sections of different characters, and is inferred to separate continental from Franciscan basement at depth. With the Newport-Inglewood zone it forms a coherent structural system that has allowed Franciscan terrain of the continental borderland to move northwestward along the Newport-Inglewood zone and down bencoth the leading edge of the Transverse Ranges along the Molibu Coast f ault.

3.2 SITE GEOLOGY The Atornics International NMD Facility is located near Canoga Park, Ventura County, California. The site comprises opproximately 1,500 ocres of which the test facility occupies an area of some 82.19 acres. The geographic coordinates are approximately 34 14' N and 118 42' W with elevations ranging from I,650 to 2,250 feet above sea level.

The site lies entirely within a pocket known as Burro Flats, formed by the higher surrounding Simi Hills md affording relative isolation from the surrounding communities. Its higher elevation, ranging from 800 to 1,000 feet above the populated valley floors, serves to enhance its isolation. This site is situated in rugged terrain typical of mountain creas of recent geologic oge. The site may be described as an irregular plateau sprinkled with outcroppings above the more level patches and with peripheral eroded gullies. Elevations of the site vary from I,650 to 2,250 feet above sea level.

3.2.1 STRATIGRAPHY The Simi Hills, Santa Monico Mountains, Santo Ana Mountains, and Elsinore localities have very similar stratigraphic sequences md depositional environ-ments (Sage, 1971, 1973). Principal sequences in the study area include the 844 v

3-5 TERA CORPORATION

Paleocene Simi Conglomerate member which disconformobly overlies the Upper Cretaceous " Chico Formation" and is in turn graditional with the Las Virgenes Sandstone and Burro Sandstone members. The Eocene Santa Susano Shale and Paleocene Burro Sandstone contact is disconformobie in the Santa Susano Mountains, is gradational in the eastern Simi Hills and is unconformable in the western Simi Hills. Sage (1973) suggests that the Simi Conglomerate member and the overlying Burro Sandstone member represent at least four separate depositional environments.

3.2.2 STRUCTURE There are two faults in the immediate site crea that require discussion.

Santa Rosa Fault. This fouit (also known as the Simi fault, and at the northeast end, os Los Llojas fault) lies 5.5 miles northwest of the Burro Flats site, where it extends northeastward fo.

'O miles parallel to structure in the late Cenozoic Ventura basin. Little is known of the fault from the published literature, but it must at least tentatively be considered to have had late Quaternary displacement.

The fault is a northwest-dipping thrust fault, and this sense of displacement is also suggested by the distribution of stratigraphic units on the state map. This geometry seems to associate the fault with Ventura basin structure, so that it probably is a relatively young fault.

Santo Susana Thrust. Along the south margin of the eastern end of the Venturo basin, eight miles north of the Burro Flats site, late Cenozoic rocks have been thrust southward along the 15-mile Santa Susana thrust for at least I-l/2 and possibly five miles. Soul (1975) concludes that this fault is currently inactive and that motion on the fault has not occurred since the middle Pleistocene. Because of its proximity to the site, this fault is treated in particular detail in Section 5.0.

3-6 TERACORPORATION

3.3 GEOLOGIC HAZARDS Non-tectonic geologic hozords for The Atomic International NMD Facility have been evolucted. This has been done on a preliminary basis with emphasis placed upon a search of the literature and review of maps of the creo. In addition, a brief site visit was m_de and included both the fccility proper and the immediate surroundings.

3.3.1 FAULT OFFSET HAZARD Based on existing geologic information (Soge,1971 and 1973), there are no known active foulis underlying the structures in the study creo. Therefore, o potential hazard resulting from surface failure or fault offset of the site is considered to be very remote-As to local faulting, there is on east-west trending left laterol fault positively identified and located in general across the southern boundary of Burro Flats proper (refer to Plate I of Weber et o!.,1973). Other faults include one trending northwesterly, separating the Chico and Martir.e formations which con be traced from the Los Angeles - Ventura County line westward to west of Runkle Canyon. Fault planes appear nearly vertical with a steep downward dip; the f ault is inactive and has not moved for millions of years (Focilities and Industrict Engineering Group,1975).

3.3.2 SOIL LIQUEFACTION Soil liquefaction is a phenomenon in which a saturated cohesionless soil layer located close to the ground surface loses strength during cyclic loading such as imposed by earthquakes. During the loss of strength, the soil ocquires a mobility sufficient to permit both horizontal and vertical movements. Soils that are most susceptible to liquefaction are clean, loose, saturated, uniformly graded, fine grained sands that lie within 50 feet of the ground surface.

844 3-7 TERA CORPORATION

A problem in southern Ventura County equo!!y as serious os the identification of active faults is the problem of identifying the geologic units os to their seismic response chorocteristics. Richter (1959) stated that much of the olluviated area of the Santa Clara Valley and the Ventura basin should expect shaking sufficient to cause considerable domoge in specially designed buildings and great domoge to normally substantial buildings. In the eastern part of the Ventura basin '.his was demonstrated during the San Fernando earthquake. The expected demoge to creas where ground water is within !5 feet of the surface could be even greater, but would be relatively less in creas underlain by older alluvium and even less on more indurated or cemented Tertiary rocks. Oider landslides may be reactivated or new landslides may originate in some areas of Tertiary rocks of the county during on earthquake. A summary showing how various building site materials may respond to shoking that leads to liquefaction is provided in a report by Borosh (1969).

Because the soil cover is so thin to non-existent at the site and because the ground water system is virtually non-existent and at considerable depth, the possibility of soil liquefaction occurring of the site is very remote. Relatively firm bedrock is the surficial material at the site.

3.3.3 LANDSLIDES Landsliding is widespread in southern Ventura County, especially in rocks of the Pico, Santa Borboro, Monterey /Models, and Rincon formations and also in rocks of other formations. Large slides are prominent along major fault zones, such as along the apparently active San Cayetano and Ock Ridge faults.

Existing bedrock landslides range in age from the late Quaternary to the present.

Specific mapping of landslides in Ventura County hos been done by Neel (1969-1970) and Leighton (1966).

Landslides, slumping and other indications of slope failure are not evident on Burro Flats proper. Exposures of stable bedrock, little soil cover and low relief inhibit the mass movement of rock materials.

bkk TERACORPORATION

4.0 SEISMOLOGY While the detailed elements of the ceismic risk assessment are discussed in Section 5.0, the historical seismic record is of such significance that it is dis-cussed separately below.

A complete evaluation of the historical record is the keystone to the risk assess-ment because of the important time and spatial distribution information it contains. With regard to time, the record provides detailed nistorical earthquake frequency information that can best be represented by the relationship, log N =

a-bM. Further, the spatial d;stribution of earthquakes around the site con of ten be used to delineate seismic source regions within which earthquakes have common characteristics.

Unfortunately, earthquakes have been reliably reported only since the 1930s when a nationwide earthquake instrumentation program was started. The pre-1930 record is a very valuable supplement to the recent recorded dato 591 due to sporce settlement cnd scattered intensity reports, much of these data connot be reliably used in developing earthquake statistics. In addition, the hypocentral locations are sufficiently inaccurate that, except for very large earthquakes, it is virtually impossible to associate either the historical or instrumental seismicity with particular faults. Furthermore, the recurrence intervo! for those larger earthquakes that con be associated with faults :s believed to be several times longer than the historical seismic record.

Since necessary input to a seismic risk calculation includes estimates of the seismic octivity rates on the specific faults in the site vicinity, we are faced with two alternatives. The first alternative would be to subjectively allocate the regional seismicity to the specific faults. There is little basis for this approach because of the density of faults in the vicinity of the site. The second alterna-tive is to use available geologic information for each fault to provide on estimate of the " secular" seismicity (Allen, et al.,1965) on each fault. This alternative provides on opportunity to accurately describe the recurrence of large 844 4-1 TERACORPORATION

5 earthquakes through examination of up to 10 years of earthquakes as contained in the geologic record. This approoch, which is oppropriate only where there is sufficient geologic information, is the approach selected for this study.

The following section, Calculations And Results, develops the seismicity model based on the geol:r,ic record and compares this model with the regionc! seismicity.

In the following sections, we review the historical and instrumental record of seismicity in the vicinity of Santo Susano, discuss the capable faults in the crea, conclude that the seismic record is insufficient to chorocterize the seismicity of the individual faults.

As an overview perspective, we present in Figure 4-1 a seismicity map of California. Note first the structural complexity of the Los Angeles crea as opposed to other parts of the state. For example, the significant structurd features in the Son Francisco Bay Area cro three principal faults:

the San Andreas, the Hayward, and the Coloveros Foun ts. On the other hand, significant structural features in the site creo consist of more than 12 active faults, only six of which are illustrated in Figure 4-l.

A more detailed presentation of the capable faults in the area is given in Figure 4-2. Returning to Figure 4-1, note the relative aseismic character of the site crea in the Los Angeles Basin relative to, say, the Son Francisco Bay Area. These two points, structural complexity and relative aseismicity, characterize the difficulty in developing seismic activity rates for faults in the site area.

In spite of the relative aseismicity of the site area, there have been teveral significant earthquakes on nearby faults.

These events serve to define the seismic capability of the entire region, and further serve or a benchmark against which any seismicity model must favorably compare. Figure 4-3 presents the detailed seismic history for magnitude 5 and greater events in the site area, and Table 4-1 lists the most significant events that have occurred in the Los Angeles Basin since 1857.

844 E

4-2 TERACORPORATION

D

  • D"3 a

D]

_w 6

.du a

S

.v"

.e.. _.. c.

g"------r-"

CALIFORNIA EARTHQUAKES l

i l

s 1900-1931. M > 4.0 OR I & 5 l

I\\ !**

"i ~

t Integer - Maximum reported intensity

.s ja,s I

g s

4 i

6sa$e'TUOE v

.cp b) -

)

i

't 1

8L a s o-s e l(\\\\

l 4

,/

3 i

a so-se

  • j O

7O-?9 l

I

%l a s o-s e

.e.

Ms

a x i

v-s x

s s l

,.. i V. n A..,

j

%^

L 1

e.

s N\\'a

[

\\J

=-

3

\\

A

\\e p,.

y h _ _

_._ - +-

4, a

'w vs 1, p,,.

5 s4 N

x

%s l

..,... uu,,,...

. m.u

- f r y =; w

=.

e..,...,.e,...

w-i.>,n.

~ u m,,, a...

.u, t

5 I

r 4

. Om;.

i.,u.

.. n w, s..

.,1..-.,,m1.,.

l's_f

.u,

..J.

g,

,, 3, a

.... ~,.,.

z s

J' 1

s,'

FIGURE 4-1 CALIFORNIA EARTHQUAKES 1900-1931, M 2 4.0 OR I ?._ 5 (From Toppozado,1978)

~_

t O44 f

W

,. O,s ;, l Vv__

TERA CORPORATION y - -- -

uOa g;g

a

/

a l

l l

- no &

p wM w

  • &uc Tal*ua sir ? *

, t __

\\

gog

%eg k

4

\\ N ss'a gwa gn w re

  • w in 'w FIGURE 4-2 FAULTS IN SOUTHWEST CALIFORNIA WITH DEMONSTRATED QUATERNARY DISPLACEMENT (From Jennings,1975) 84d TERA CORPORA]ON

n u -ek, a

% a' s

A r

H

  • canosa mes al 2 nut.sL se

~

ne

  • w a

ree' w e

e a

a o

Ic 20 30 m t

t t

l EARTHQUAKE EPICENTERS s

E 5.00 s ML s 5.99 A 6.0 < M FIGURE 4-3 EARTHQUAKE EPICENTER MAP 844

.2 TERA CORPORATION

TABLE 4-1 MAGNITUDE 6 AND GREATER EARTHQUAKES IN SOUTHWEST CALIFORNIA Year Description Magnitude Lat.

Long.

1857 Fort Tejon 8.0 1916 White Wolf 6.0 34.9 118.9 1925 Santa Barbara Ch.

6.3 34.3 119.8 1927 Point Arquello 7.5 34.5 121.0 1933 Long Beach 6.3 33.6 l18.0 1941 Santa Barbara Ch.

6.0 34.4 119.6 1952 Kern County 7.7 35.0 I19.0 1952 Aftershock 6.4 35.0 119.0 1952 Aftershock 6.1 35.4 118.6 1952 Aftershock 6.1 35.4 118.9 1971 San Fernando 6.4 34.4 118.4 1973 Point Mugo 6.0 34.1 119.0 844

'.n 4-3 TERA CORPORATION

5.0 CALCULATIONS AfO RESULTS In the previous sections, we have described the regional seismicity around Santa Susano and have discussed the most appropriate method of risk analysis. Ir this section, we apply these concepts to the NMDF site. The detailed input to the calculational model is described below, followed by a presentation of the results.

5.1 INPUT As described in Section 2.0, Seismic Risk Methodology, the input to a probabilis-tic risk assessment comprises earthquake frequency relations, attenuation func-tions and a specification of local source regions.

Because risk assessment calculations are very sensitive to the particular composition of the input, we consulted with several seismologists during the preparation of input for the NMD Facility analysis.

5.1.1 SOURCE REGIONS The capable earthquake sources are of two broad classes; specific earthquake fault sources and diffuse areal sources.

9 Our selection of the specific faults for the risk model was guided by the work of Jennings (1975) and was therefore restricted to faults on which there has been Quaternary displacement. Further, based on sensitivity studies with preliminary seismic risk models, we restrict the faults selected for detailed modeling to those within 100 km of the site. The resulting set of specific faults is presented in Figure 5-1.

The region of diffuse seismicity in our seismicity model accounts for the difference in the observed regional seismicity and the accumulated model seismicity for the faults on Figure 5-l. This source region, therefore, accounts for our uncertainty in prescribing activity rates for specific faults, where this uncertainty is first contained within our specification of the activity rate, and

.r TERACORPORATION

va r5L l

1 I

-.s p wAZ-

%M "o garusue Un sir !

  • g N
  1. ',*__7 l

4

\\'%

l ss*u jggar (19

  • W

!!9

  • n' il1 *%'

FIGURE S-1 FAULTS IN SOUTHWEST CALIFORNIA WITH DEMONSTRATED QUATERNARY DISPLACEMENT (From Jennings,1975)

Od #f Ob TERA CORPORATION '

second in our selection of the "octive" faults. Including the areal diffuse region allows for possible seismicity on other minor, or poorly understood faults.

5.l.2 MODEL SEISMICITY As discussed in the previous section, the seismicity md structure of the site area are such that conventional approaches for allocating historical and instrumental seismicity fail becauce of the uncertainties involved. In this section, we develop m independent assessment of possible seismicity on the site crea faults based on available geologic information.

The geologic information we require is the overage annual slip rate of each fault. We incorporate the best estimates of the slip rate for the specific faults into the slip rate-mognitude relations presented by Campbell (1977) and Anderson (1978) to derive these octivity rates. Table 5-1 lists the specific faults considered here, specifies the slip rate and its reference, and indicates the best estimate maximum earthquake for the source.

We use the dato in Toble 5-1 olong with the "b" value of 0.86 determined by Allen, et al., from o statistical analysis of over 10,000 earthquakes to determine the activity rates for each fault. Table 5-2 presents a summary comparison between the seismicity predicted by this model and the octual recorded seismicity for the most active faults in the site crea. Note that the seismicity of the diffuse zone is, os described above, designed to model the observed diffuse seismicity. Our best estimate of the activity rate in the diffuse region is plotted in Figure 5-2.

In Figure 5-3, we present a comparison of this seismicity model with the dato.

The mode! is seen to overestimate the number of events per year with mognitudes less than 7, and underestimate the historical rate of events with magnitude 75 to 8. In no cose is the rate for events less than mognitude 7 off by more than a factor of 2 from the data.

The mognitude 75 and 8 dato are based on so few earthquakes tnot the points can not be considered reliable. Sieh (1977) provides geologic data for recurrence rates of major events at two sites on the Son Andreas fault: Pallett Creek anet en m

ou 5-2 TERA CORPORATION

TABLE 5-1 Geologic Slip Rote Maximum l~oul (mm/ Year)

Citation Earthquake Rinconc.do 3.0 ll 8.0 Hosgri 10.0 12, 13 8.0 White Wolf 0.4 2

8.0 Santo '(nez 2.0 10 8.0 Big Pi e 2.0 2

7.5 Gorlock 8.0 2

8.0 San Cayetano 0.05 10 7.5 Sor. Andreas 40.0 1

6.5 Santo Svano 1.2 5,6,7,8,9 7.0 Sierra Madre 8.0 2

7.5 Malibu Coast 0.15 3

7.5 Oakridge 0.3 16 7.0 Newport-Inglewood 0.3 3, 4, 15 7.5 Palos Verdes 0.7 14 7.5 Chino 0.07 14 7.0 Elsinore 0.8 2

8.0 CITATIONS 1.

Ehlert and Ehlig (1977)

2.. Lamar, et al. ( 1973 )

3.

Hill (1971) 4.

Yeates (1973) 5.

82 nhart and Slosson (1973) 6.

Ehlig (1975) 7.

Soul (1975) 8.

Hazzord (1944) 9.

Ingram (1959)

.0.

Dibblee(1966) ll. Hcrt (1976)

12. Weber and Lajoie (1977) 14.

Yerkes, et al. (1965) b'4

[]'}3

13. Graham and Dickinson (1978)

,j A l

~

~

15. Wright, et al. (1973)
16. Guid< (19~,3) 5-3 TERA CORPORATION

T ADLE 5-2 COMPAltlSON OF THE MODEL SEISMICITY WlIH THE DATA TOlt SEVLilAL SIGNIF ICANT FAUL15 MAGN 11UDE I

8.0"

[ 7.0 I

I 3

I 2

2 2

2 7.5 SUBREGION 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 Events / rear (Data) 5 En' ire region 54.0 66.0 27.0 8.80 4.000 1.200.360u.2200.0540 --..0170.0003 San Andreas

---.0083 Hosgrl

---.0083 Newport-Inglewood l1.0 05.6 01.9 0.66 1.000 0.390.0970 ---.0140 ---

White Wolf 14.0 32.0 08.7 2.40 2.300 0.560.1700.1200.0140

--.0083 Sierra Madre 08.7 08.8 07.2 3.20 0.440 0.0!3.0240.0400.0140 ---

Remainder 22.0 16.0 09.6 2.60 0.850 0.170.0730.0480.0140 ---

Y Events / year (Model)

O San Andreas 3.700 1.400.5000.19f.0700.0260.0096.0022 Hosgri 0.590 0.220.0810.0300.0110.0041.0010 ---

Newpor t-Inglewood 0.027 0.010.0038.0014.0005.0001 ---

0.016 0.006.0022.0000.0003.0001.0001' ---

White Wolf Sierra Madre 0.620 0.230.0860.0320.0120.0044.0010 ---

2 Dif f use zone 33.0 09.6 2.fxl 0.840 0.250.0730.0220.0064 ---

G:.

6 1.

Data from NOAA carthquake data file 1953.0 - 1974.33 2.

Data from NOAA carthquake data file 1933.0 - 1974.33 C

3.

Data from Table 11 1903.0 - 1977.0 g

LD 4.

Data from Table il 1857.0 - g977.0 g>

h 5.

33.0 - 35.5 N,117.5 - 121 W O

6.

Rounded up O

Seismicity obtained empirically to match arenminder in data 7.

m OZ

I 10 i

\\

\\\\

0 10

\\

i i

\\'

i

\\!

I k

e b

l l

l E

10'1 l

E s

[

z g-i i

\\

t u:

i I

I

\\i i

l

\\1 I

i

\\

I i

10-2 l

i l

i I

i I

l 10-3 2

3 4

5 6

7 MAGNITUDE 844 055 FIGURE 5-2 RECURRENCE RELATION FOR THE DIFFUSE SOURCE REGION (33.0 - 35.5 N, i 17.5 - 121.0 W)

TERA CORPORATION

3

~

i i

i i

i Southern California 33.O'N - 35.5'N 117.5* W - 121* W 2

O O Historical Seismicity 5

I All Foum

$o.

O N

-Son Andreas 5

z 9

.\\

N g

_i All Faults except Son Andreas

-2 m

Pollett Creek -

Wallace Creek

-3 I

I I

I I

3 4

5 6

7 8

M t FIGURE 5-3 HISTORICAL SEISMICITY 644 036 d

TERACORPORATION

Walfoce Creek. Rates implied from his dato are also plotted on Figure 5-3.

Thus, it appears that the seismicity model, based on slip rates, does a reasonable job of estimating the overall seismicity of this region.

However, study of the details in Table 5-2 shows that even though the overall rate for the crea is estimated fairly well, the rates for individual faults are almost unrelated. The San Andreas represents the most notable point: although the slip rate implies that it should be the most active fault, it has been completely inactive during the instrumental period. The high seismicity in the total is obtained because the Newport-Inglewood and the White Wolf faults have been considerably more active than the geologie dato predicts. The discrepancy appears to crise because the historic interval is so much shorter than the recurrence intervol for the faults in the creo. Allen et al., (1965) discuss this problem in considerable detoil.

From this viewpoint, the more remarkable observation is the apparent coinci-dence of the total rates for the creo. Either these total rates are similar because of a lucky coincidence, or the seismicity of the region as a whole is o more stable paro neter than the seismicity of selected faults within the region.

Since the cause of the seismicity appears to be relative motion of the Pacific and the North American plates, and since that rate is fairly uniform so for as is known, the unifc,rm rate of strain occumulation which is implied suggests a physical explanation for the second hypothesis.

One particular fault in our model warrents particular discussion. Because of its proximity to the site, the Santo Susano fault is a major contributor to the seismic risk of the Facility. Our best estimate of the activity on this fault is based on a slip rate of 1.2 mrn/yr (Toble 5-l). We summarize below the basis for this slip rote and indicate its uncertainty.

The published data on the fault is rather extensive considering its short length (40 kilometers). The literature we consulted included the following:

Bornhart and Stosson (1973)

Oakeshott, G.B. (1955)

M 4 057 5-5 TERACORPORATION

Evicon Corporation (1976)

Bishop, R.J. (1950)

Slosson and Barnhart (1967)

Jennings, R.A. (1957)

Proctor, et al. (1972)

Ehlig, P.L. (1975)

Hazzard, J.C. (1944)

Ingram, W.L. (1959)

Of these papers, two are most significont.

Bornhart and Slosson (1973)

Quote Oakeshott (1958) in saying there is "about 2.5 km of horizontal shortening and vertical separation." The fault merges to the east with a series of faults that become the Sierra Madre fault system. "In the Santo Susano Moun-toins, Tertiary is thrust over Plio-Pleistocene sediments and to the east, basement was thrust up and over Pliocene and Pleistocene sediments.

Recent studies strongly suggest post-Pleistocene orogenic activity along the cen-trol and western portion of this fault zone."

If there is 2.5 km offset since the beginning of Pleisto-

cene, 2S 1.2 mm/yr

=

my if it occurred since upper Miocene, 2.b

= 0.25 mm/yr 0

Ehlig (1975) in the same volume as the article by Soul (1975), Ehlig states that " uplift of the Santo Susano Mountains has occured during the late Pleistocene and Holocene."(p. 18)

Therefore, using i my rather than 2 my to estimate the slip rate, we get 2.5

= 2.5 mm/yr Again, we judge a best estimate slip rate of 1.2 mm/yr but the above discussion establishes that the uncertainty is a multiplicative factor of two.

844 058 "

5-6 TERACORPORATION

In summary, for the development of our seismicity model we have extended our information base to include extensive geologic information and in so doing have determined realistic and credible estimates of octivity rates that could not otherwise be determined.

The validity of the model is established by the comparison in Figure 5-3 between the regional seismicity and our model.

5.l.3 ATTENUATION One of the keystones to any seismic analysis is the specification of decay of peak acceleration with distance from the earthquake. Credible ottenuation relations have in the past been difficult to develop for two reasons: first the large scatter in the data makes a deterministic evaluation very difficult and second, the data are very sparse in the near-field, thus allowing for a variety of interpretations.

Because of its particular significance at this site, a very careful re-evaluation of all the data was performed in order to ensure state-of-the-art interpretation and maximum credibility (Boore,1977).

The overcil approach to development of an attenuation relation for this analysis is os follows:

1)

Use oppropriate data in the range 20-100 km to estimate the far-field attenuation.

2)

Focus on the acceleration dato at ~ 10 km to fix the trend in the near-field.

3)

Rely on all available dato points at ranges less than 10 km to establish the very near-field accelerations.

Peck acceleration data for development of the attenuation relation were collected from the following sources:

e Brune, et o!.,1977 Galanopoulos and Drakopoulos,1974, e

vw4 Q) ;E' ~"7

.A?

A h

5-7 TERACORPORATION

e Hanks and Johnson,1976 e

Boore, et al. to be published,1977 USGS Circulars; 672,1972 717-D,1976 713,1974 736-A,1976 717-A,1975 736-B,1976 717-B,1975 736-C,1977 717-C,1976 736-D,1977 The magnitude range 5.0-7.0 has been emphasized in the data collection and interpretation in anticipation of the significant magnitude level of earthquakes in the Santo Susana crea. As on illustration, Figure 5-4 shows the data in the magnitude ranges 6.0 -7.0.

The emphasis in this figure is on the 20-100 km ranges, but the available very near-field data (less than 10 km) are also plotted.

In this model, range is usually the distance to the nearest point on the fault or the distance to the zone of principal energy release, if this con be determined.

The data are for both rock and soil sites since there appears to be ne statistically valid recon for their discrimination (Boore, et al.,1977). The relations are, therefore, for a typical, average site. Superimposed on the data in this figure are the attenuation relations that result from consideration of all these dato. We include two ottenuation relations here to capture the uncertainty associated with the extrapolated near-field accelerations.

The scatter about these mean relationships is best characterized by a log normal one standard deviation of 0.45. This fits the data reasonably well and is consistent with the dispersion calculated by other investigators (e.g., Donovan, 1974), considering that our analysis is for a specific site in a specific tectonic setting.

The recommended attenuation relations, which are a blend of judgment and regression analysis, are summarized in Figures 5-5 and 5-6 con be characterized by the analytic expressions:

H = 6.7 exp (0.277M +.016 M ) (r + 10)-l.75 2

A

+ 0.04 M ) (r + I 2)-l.75 3

2 AH = 0.193 exp (2.98 M - 0.58 M H s in fraction g.

where r is in kilometers and A i

t 5-8 TEPA CORPORATION

2.0 -

Attenuation 2 O Pocoimo 1.0 -

0.8 -

Attenuation 1

= =.

. g * %,Koync 0.6 N.

  • Leukes 0.4 -

.N.

Monogue N.

O N

O

's 0.2 -

O

\\

OO O

9 g

e 4

[

c. _

O 's.

O

<:: 0.05-O \\ O d

-- 0.06 -

\\,

og g

C O

C 0 gg 0.c m

R E

\\

= 0.02 -

o. O k

.\\,

r 0.01 -

0..so -

0.006 -

6W7 0.004 02-21-73 Pt. Mugu 3

A 04-09-6B Borrego Mountain 0 02-09-7i Scn Fernando 0.001 -

1 I

I IIIII I

I i

I I I IIi l

l 1.0 2.0 4.0 8.0 10 20 40 60 80 100 200 RANCE (Km) 0 14 d" b j FIGURE 5-4

'r*

TWO ATTENUATION RELATIONS USED IN THE TERA ANALYSIS TFRA CORPORATION

ATTENUATION 1 (2.98

.58M +.04M )M A = 0.193 e (r + 12)~1*75 i

4 4 7" - - { ' i j

_1_~ -Mi_2.- + i-T -t-M '

- - -- ] -

1

..! l - ! T *, _ _-- :4 cd -4: T i_i

- :.:' l --

t_-l

.-. *{,

._;-- 4. --

fri :.__--

_- r.:

._; i - p

! i- _ r--

_c_j -i -_- !

.2-Ti l

4.

- _-d. - j -i ! ! j ;1 } _-g-j _. #Zi 3-11 ~ _ =.- :

1. 4

-. _a:-.._:- ; 2_: l r _ --

4 4

t :. __

.:.L..

t _. t u-

.. _ _,,.~

~ _.

  • r :

.2:

t 1.c -

7 5.x g.

e

,X __

N

-. ~. N-

-_ } - _

f, l.; --

-4 5.5

_y, w _y__

_ :, _ g _.__.

c p

4.5

.g -gy ;

. g 3 -p y

, _, A-y g_ -

.Z

-1._j__ i -::

_ j --4 h%., - ' ;.. 'T:

f~1l--1. p.}

r_ a W

--i 5

~_-

..._. I ~ ' -..l _~ k%M_~ M 4;'.JI I4-__

r' l. ~~. ;....'."]... ! l.' C.'

Z....,

!_. { '

0.1 s.s s _.

s__

.g g

.g _.

g.

,g.g g..._4 N. _.

. _. u.g., m....._.

__ :- ;._: ; - - - 4_.j, 3 a 3 -- _.=_;i.mga. a _+N _..! ;

. a -

.i-i j :-] _; - !" Ti - - = 1 e M \\ M H N ---- c~ :

Z i.~ i -i(! t_2 i -- -E-.i yMiW!\\--El

~-

1 2 J,-. -I

( i (%,

1.j jt

-,. {[ - 7 ' - Id.I i --

~

3.kl j k !

l

.j ].j

__2 - - - :

..)-

i' J_. = - d 1 F iti_. W -t F i = i t l r:1.j h

~ 3 - i ~

.1

~~-

l

..l

-- l Ti. =. ___.

t..x- -3..;

i

...,... f.. ;

..j..

q.. 4

.. _.. ). q..

3 1.0 10.0 100 1000 DISTANCE (km)

FIGURE 5-5 ATTENUATION RELATIONSHIPS

[j 4 i}

} (,) n -

/

TERACORPORATION

(:*'N'JATION 2 A = 6.7 e (r + 10)"I "

....,i

4. -

t-j 4 i. -__- _: --+. _ i _7 ' ;-M-j ! !_], M a_ ---

4--

t 4

t;: I --'

---4.. li_ i~ ' DT W '._:.--~

  • ~
  • _t-

- - r- '. a _ i ---.

..2.

1..:~--

.'__---}.

r-

'----} -- 7_ d j f "hi-j-

_: ?- -t ~-T_; --h -F._!.'

i

--Z-

~

a -T l -f i :

1.E 1:22:2- ~ l 1. :__ --~~ '

2_

-!43~i_9-n.J.

- :__ I.

___J +-:

~...

i

-21 r-

..... I ;n. _. _.

_ : 1.

____. t

: *_.._.,.,~.. - -

n.

1.0

,7 c

~ ~ ' - ~

- s 6.5

--A g..

g_

?

5 ' 5 N--%

N-N. _x

_.
- 4.4. L :--._ 1 E

!4.5 g

. K n Q --- N _ _ - = = -3;. p : _- -

2

...>x

-N 5

i : __

5

'-]K-- _ h j-A_ r - -4 ;3 1 - ri-}--

.~3'

( j ---- :.;

. - - +

\\t ~~ ' _-*- T j 3,3 *.... -

y I**._

3 5

1 j - -., --

..y ] '

-* "^ AQ:N 11 J.:{.

w i

..w.

-t :,.

s

=

4. w...

0.1

.-...-..j. %... 4

(

x.+ w

._.y

g. %

,x -

.. y.. g g -.. g.

g. \\_.g.

.N-,.

6

. ~...

_.{

-1.q i;ri M 1:- r.3(_.gm.y.; _N rt - _.

_: ---j" 2

.._ t-i 1. i _J. ; j =7.___{ --Q _y-T

[\\ ! :-- -

i.-;

a ; --- - -

u

. 22.:3 -- - q :. -.\\ _4. : s- -._;

i.T::t : -. :.. :-. "

..g

?

=

%t.: A4 i

- : !..__ f.. '... I -- :.:4:;- --

- - - - 41 \\- y:

E-\\. M.2 :,--g.

j i

i -i-C.l-.

j '

5p i --El -._ _... IE

_. l-Mi 1 1

-m

':$r k}.[li r-_5 % 5 ~~ -k N M T.}----


I'._.

i t

q --* 1..,,.<_.

4...

.,. '.. ---.t.

-,. q2 -.. _. ~ -

.4..

q.

g a

6 1.0 10.0 100 1000 DISTAlCE (km)

D FIGURE 5-6 ATTENUATION RELATIONSHIPS o:,71 l.

()a/T i

s TERA CORPORATION

5.2 RESULTS The results were obtained by computer calculations with a risk analysis code (Anderson and Trifunoc,1978) that is based on the work of Cornell (1968). The basis for this approach was summarized in Section 2.0.

As described in Section 2.0, the computer code calculates the expected number of earthquakes causing accelerations greater than a specified acceleration and this is done for each source region and the host region. The expected numbers are summed for each region, and the resulting risk calculated from risk = 1.0 - exp (- total expected number).

The return period associated with the specified acceleration is then the reciprocol of the risk. It follows from the definition of return period that occelerations with a porticular return period have a 63 percent probability of being exceeded within the return period.

Our estimate of the seismic risk represents the weighted results from five individual calculations. The five calculations represent a base case and our perturbations of input parameters about this base.

The perturbations are weighted by subjective estimates of their probability of occurrence and thus their weighted combination con be considered a Boyesian estimate.

The parameters that are considered uncertain and which are included in our estimate of the risk are the activity rates for the Santa Susana fault and the Diffuse Source region, and the magnitude of the data dispersion about the mean acceleration attenuation relationship. The variations of these parameters repre-sent the overall uncertainties in:

Our ability to define the strain energy limit of faults e

around the site d4064 N

TERA CORPORATION

e The correlation between earthquake magnitude and inten-sity e

The shape and level of the attenuation relation The base case is considered to consist of the following input:

Best estimate activity rates for the Santa Susana fault e

(1.2 mm/yr slip rote) and the Diffuse Source region (Figure 5-2) e Acceleration one standard deviation dispersion, c InAH = 0.45 We characterize the uncertainty in these data by considering that it is roughly 70 percent probable that the activity rates on the Santo Susano fault and in the Diffuse Source region will be as specified above. We consider it roughly 15 percent probable that the activity rates would be double our best estimate end also 15 percent probable that the rates would be one-half our best estimate.

Note that this -c.ge covers the uncertainty in the Santa Susana slip rate.

Similarly, we consider that it is 70 percent probable that the acceleration disper-sion is as specified above and that it is respectively 15 percent probable that the dispersion will be 0.35 and 0.55.

The results from these five sets of parameters have been combined to produce our Boyesian best estimate in accordance with the probability of the combina-tion. These results are presented in Figure 5-7. Also shown in this figure is our estimate of the plus and minus one standard deviations about our best estimate results. These were derived by assigning equal weights to respectively the two more conservative and less conservative sets of parameters.

5.3 RESPONSE SPECTRUM i

These results define the peak horizor.tal acceleration at the facility for various return periods. We have also determined on appropriate response spectrum for the site since some structures and equipment at the NMD Facility have sufficiently low fundamental frequencies to experience spectral amplification of 45 O

J ge

-i0 TERACORPORATION

10"

/

'3 s'

s' r

s

/

/

/

/

/

/

/

/

l

/

/

/'

?

/ / /

w

_h2

+

-0 10 x

l l

E l

l

,/,/,/

z 5

i

/

/

/

i C

/ /

/

// /

I 10 BEST ESTIMATE 0

10 i

0 10 20 30 40 50 60 70

%g FIGURE 5-7

3 4 t; O6b RETURN PERIOD - ACCELERATION FOR THE NMDF TERA CORPORATION

the ground motion.

The response spectrum for the site clearly cannot be developed in association with a specific earthquake; our return period accelera-tions represent an integrated effect at the site from on extraordinary variety of earthquakes and the response spectrum must reflect this. Accordingly, we judge that the shape of the spectrum should be similar to the Newmork-Blume statistically-based spectra from which Regulatory Guide 1.60 evolved. Accord-ingly, it is our judgment that the mean response spectrum for rock presented in WASH 1255 is the most appropriate for analysis of the NMD Focility. The uncertainties in this judgment cre, however, large; there is probably a 20 percent probability that the spectral accelerations could exceed the 75 percentile occelerations in WASH 1255.

In summary we have combined the best available input data with the most credible tools of seismic risk onclysis to determine the return period of acceleration at the NMD Facility. The results, shown in Figure 5-7 cecount for all the significant uncertainties in the input. Response spectral accelerations can be determined by scaling the mean response spectrum in WASH 1255 to the desired peak occelerotion, t

0* M

=

5-11 ev-g TERA CORPORATION

6.0 BIBLIOGRAPHY Aerial Photographs, Pacific Aerio! Surveys.

Algermissen, S. T.,1969. Seismic Risk Studies in the United States. 4th World Conference on Earthquake Engineering, V. I, p.14.

Algermissen, S. T.,1974. Seismic Risk Studies in the United States. 5th World Conference on Earthquake Engineering.

Algermissen, S. T. and Perkins, D.

M.,

1976.

A Probabilistic Estimate of Maximum Acceleration in Rock in the Contiguous United States: USGS Open File Report 76-416.

Allen, C. R., St. Amord, P.,

Richter, C. F.

and Nordquist, J. M.,

1965.

Relationship between Seismicity and Geologic Structure in the Southern California Region. Bull. Seism. Soc. Am. 5_5, pp. 753-797.

5 Anderson, J. G.,1968. Estimating the Seismicity from Geologic Structure for Seismic Risk Studies. Submitted to the BSSA.

Anderson, J. G., and Trifunoc, M. D.,

1978.

Uniform Risk Functionals for Chorocterization of Strong Earthquake Ground Motion. Bull. Seicn. Soc.

Am. 68, pp. 205-218.

Anderson, P. M.,1943. Synopsis of the Later Mesozoic in California. Calif.

State Div. Mines, Bull. Il8, pp. l183-1186.

Bornhart, J. T. and Slosson, J. E.,1973. The Northridge Hills and Associated Faults-A Zone of High Seismic Probability? In GSEl, p. 253.

Barosh, P. J.,1969. Use of Seismic intensity Data to Pre Tct the Effects of Earthquakes and Underground Nuclear Explosions in Varicus Geologic Settings: U.S. Geol. Survey Bull. 1279,93 p.

Bishop, R. J.,

1950.

Geology of the Southern Flank of the Santo Susano Mountains, Univ. of Calif., Los Angeles, unpub. M.A. Thesis, i15 p.

Bolt, B.A., 1978. " incomplete Formulation of the Regression of Earthqt,ake Magnitude with Surface Fault Rupture Length." Geology, Vol. 6, pp. 233-235.

Boore, D., 1977. Attenuation of Peak Accelerations, Internal TERA Report, August 13,1977.

Boore, D.,1978. To be published.

Brozee, R. J.

1976. An Analysis of Earthquake intensities with Respect to Attenuation, Magnitude and Rote of Recurrence. NOAA Tech. Mem. EDS N6SDC-2.

gaa OM TERA CORPORATION

Brune, J. N.,1968. Seisniic Moment, Seismicity, and Rate of Slip Along Major Foult Zones. J. Geophys. Res 73, pp. 777-784 Brune, J. N., Prince, J., Hortzell, S., Mungia, L., and Reyes, A.,1977. " Acapulco Strorg Motion Record of October 6,1974." Abstroet with Programs 9, Geol. Soc. Am. 394.

Campbell, K. W.,1977. "The Use of Seismotectonics in the Bdyesian Estimation of Scismic Risk," School of Engheering and Applied Science, University of California, Los Angeles, UCLA-ENG-7744.

Cornell, C. A.,1968. " Engineering Seismic Risk Analysis," BSSA g(5) p.1583.

Cornell, C. A., and Merz, H. A.,1974. A Seismic Risk Analysis of Boston: Jour.

Structural Div., A.S.C.E., l 10, No. ST 10, Proc. Paper 21617, pp. 2027-2043.

Cornell, C. A., and Vanmarke,1976. The Major influences on Seismic Risk. 6th World Conference on Earthquake Engineering.

Dibblee, T. W., Jr.,1966. Geology of the Central Santa Ynez Mountains, Santa Barbara County, California, Calif. Div. of Mines and Geology Bull.,186. 9?

P-Donovan, N. C.,1974. "A Statistical Evaluation of Strong Motion Data including the February 9,1971 San Fernando Earthquake," World Conf. Earthquake Eng., 5th, Rome 1973, Proc., Vol. I, pp. 1252-1261.

Earthquake Intensities,1972. Seismic Safety Information, California Division of Mines and Geology.

Ehlert, K. W., and Ehlig, P. L.,1977. The " Polka-Dot" Granite and the Rate of Displacement on the San Andreas Fault in Southern Califomia. Abstract, 73rd Annual Meeting, Cordilleran Section, Geological Society of America, Sacramento, pp. 415-416.

Ehlig, P. L., 1975. Geologic Framework of the San Gabriel Mountains, in San Fernando, California, Earthquake of February 9,1971: Calif. Div. of Mines and Geology Bull.196, pp. 7-18.

Esteva, L.,1970. " Seismic Risk and Seismic Design Decisions," in Hansen, R. J.,

ed., Seismic Design for Nuclear Power Plants; Cambridge, Massachusetts Inst. Technology Press, pp. 142-182.

Evernden, J. F.,1970. " Study of Regional Seismicity and Associated Problems,"

BSSA 60_(2) p. 393.

Evicom, 1976. Ground Motion Study, Atomics International Site, Simi Hills, Ventura County, California,58 p.

8kk hb

+

6-2 TERA CORPORATION

Focilities and industrial Engineering Group,1975. Site Development Plan,1977-1981: Prepared by the Liquid Metal Engineering Center of the Santo Susana Field Laboratory for ERDA, Rockwell Internationo! Atomics International Division, Vol. I,161 p.

Galanopoulus, A. G., and Drakopoulos, J. C.,1974. "A T Phase Recorded on on Accelerogram," Bell. Seism. Soc. Am., Vol. 64, pp. 717-719.

Graham, S. A., and Dickinson, W. R.,1978. Evidence for 115 Kilometers of Right Slip on the San Gregoric>-Hosgri Fault Trend, Science, l19, pp.179-181.

Greensfelder, R.

W.,

1974.

Maximum Credible Rock Acceleration from Earthquakes in California. C.D.M.G. Map Sheet 23.

Gutenberg, B. and Richter, C. F.,

1956.

Earthquake Magnitude, Intensity, Energy, and Acceleration, BSSA V. 32, p.163.

Hanks, T. C., Hileman, J. A., and Thatcher, W.,1975. Seismic Moments of the Larger Earthquakes of the Southern California Region, Geol. Soc. Americo Bull. E, pp. I I 31-l 139.

Hanks, T. C. and Johnson, D. A.,

1976.

"Geophysicci Assessment of Peak Acceleration," Bull. Seism. Soc. Am., Vol. 66, pp. 959-968.

Hart, E. W.,1976. Basic Geology of the Santa Morgarita Area, San Luis Obispo County, California, Calif. Div. of Mines and Geology Bull.,199,45 p.

Hazzard, J. C.,1944. Some Features of Santa Susana Thrust, Vicinity of Aliso Canyon Field, Los Angeles County, California (Abstroct):

Americcn Association of Petroleum Geologists Bull. 2_8, pp.1780-1781.

Hill, M. L.,1971. Newport-Inglewood Zone and Mesozoic Subduction, California.

Geol. Soc. Amer. Bul! 82, pp. 2957-2962.

Holden, E. S.,1898. Catalog of Earthquakes on the Pacific Coast, 1769-1897; The Smithsonian Institute Collection No.1987.

Howell, B. F., and Schultz, T. R.,

1975.

Attenuation of Modified Mercalli Intensity with Distance from the Epicenter: Seismol. Soc. Amer. Bull., V.

65, pp. 651-665.

Ingram, W. L.,1959. Aliso Canyon Oil Field: Summary of Operations California Oil Fields, California Division of Oil and Gas M, pp. 65-73.

Jennings, C. W.,1975. Fault and Geologic Mop. California Division of Mines and Geology, Preliminary Report 13.

Jennings, R. A.,1957. Geology of the Southeastern Part of the Oct Mountain Quodrongle crid Adjacent Ports of the San Fernando Quadrangle, Los Angeles County, Californio; Univ. of Calif., Lcs Angeles, unpub. M.A.

M4 0/0 Thesis,105 p.

6-3 TERA CORPORATION

Kiremidjian, A. S. and Shah, H.,1975. Seismic Hazard Mapping of California, The John A. Blume Earthquake Engineering Center, Stanford University Report No. 21.

Kleinpell, R. M.,1938. Miocene Stratigraphy of California. Tulso, Oklahoma.

Amer. Assoc. Petrol. Geol.,450 p.

Lamor, D. L., Merifield, P. M., and Proctor, R. J.,1973. Earthquake Recurrence Intervals on Major Faults in Southern California, in D. E. Moran, J. E.

Slosson, R. O. Stone and C. A. Yelverton, eds, Geology, Seismicity, and Environmental impoet, Special Publication, Association of Engineering Geologists, University Publishers, Los Angeles, Californio, pp. 265-275.

Leighton, F. B., Long, R., and Conn, L. R., 1977. Geologic Investigation by Surface Trenching of Active Faulting on the Ookridge and Santa Susano Foults, California, Semi-annual Technical Report, in Everenden, J.F., ed.,

Summaries of Technical Reports, Vol. IV, submitted to National Earthquake Hazards Reduction Program, U. S. Geological Survey, Menlo Park, Calif.,

pp.159-160.

Leighton, F. B., compiler,1966. Preliminary Map Showing Landslide Locations in a Portion of Southern California in Engineering Geology in Southern California: Assoc. of Engineering Geologists.

Lui, S.C. and Fogel, L. W.,1972. Earthquake Environment for Physical Design:

A Statistical Analysis. The Bell System Technical Journal, Vol. 51, No. 9, p.I957.

Mark, R. K. and Bonilla, M.

G.,

1977.

Regression Analysis of Earthquake Magnitude and Surfcce Fault Length Using the 1970 Data of Bonillo and Buchanan. U. S. Geological Survey, Open File Report 77-614.

McAdie, A. G.,1907. Catalog of Earthquakes on the Pocific Coast, 1897-1906.

The Smithsonian institute Collection No.1721.

McGuire, R. K.,1974. " Seismic Structural Response Risk Analysis, incorporating Peak Response Regressions on Earthquake Magnitude and Distance,"

Massachusetts inst. Technology, Dept. Civil Eng., Research Rept. R7451, 371 p.

McGuire, R. K.,1976c. "The Use of Intensity Data in Seismic Hozord Analysis."

6th World Conference on Earthquake Engineering.

McGuire, R. K.,

1976b.

" FORTRAN Computer Program for Seismic Risk Analysis." U.S.G.S. Open File Report 76 - 67.

McGuire, R. K.,

1977o.

"A Simple Model for Estimating Fourier Amplitude Spectra of Horizontal Ground Accelerotion." Submitted to BSSA.

O.v? f. N h 6-4 TERA CORPORATION

McGuire, R. K.,1977b. Effects of Uncertainty in Seismicity on Estimates of Seismic Hazard for the East Coast of the United States. BSSA Vol. 67 No.

3,p.827.

Meyers, H. and Von Hake, C. A.,1976. Earthquake Data File Summary, National Geophysical and Solor-Terrestrio! Data Center, Boulder, Colorado.

Neel, H. H.,

1969.

Venturo Avenue Field Landslides in AAPG, SEPM, SEG Guidebook: Pocific Sections,44th Annual Meeting,6. 30-37.

Ockeshott, G. B., 1958. Geology and Mineral Deposits of the San Fernando Quadrangle, Los Angeles County, Calif., Calif. Div. Mines and Geology Bull 172,147 p.

Oliveira, C.,1974. " Seismic Risk Analysis," Earthquake Engineering Research Center Report EERC 74-l.

Page, R. A., Boore, D. M., Joyner, W. B., and Coulter, H. W.,

1972. " Ground Motion Values for Use in the Seismic Design of the Trans-Alaskan Pipeline System" U.S. Geol. Survey Circular 672.

Proctor, R. J., Crook, Jr., R., McKeown, M. H.,

and Moresco, R. L.,

1972.

Relation of Known Faults to Surface Ruptures, 1971 San Fernando Earthquake, Southern California, Geol. Soc. Americo Bull. 83, pp.1601-1618.

Quick, G.

L.,

1973.

Preliminary Microzonation for Surface Faulting in the Ventura, California Area, in D. E. Moran, J. E. Slosson, R. O. Stone and C.

A. Yelverton, eds., Geology, Seismicity and Environmental impact, Special Publication, Association of Engineering Geologists, University Publishers, Los Angeles, California, pp. 257-264.

Richter, C. F., 1958. Elementary Seismology.

W. H. Freeman and Co., San Francisco, California,768 p.

Richter, C. F.,1959. Seismic Regionalization: Seismological Society of Americo Bull., V. 49, no. 2, pp.123-162.

Soge, O. G.,1971. Geology of the Eastern Portion of the Chico Formation, Simi Hills, California:

unpublished M.A. Thesis, University of California at Santa Barbara,109 p.

Soge, O. G., 1973. Paleocene Geography of Southern California: unpublished Ph.D. Thesis, University of California of Santa Barbara,250 p.

Soul, R. B.,1975. Geology of the Southeast Slope of the Santa Susano Mountains and Geologic Effects of the San Fernando Earthquake, in San Fernando, California, Earthquake of February 9, 1971, Calif. Div. of Mines md Geology Bull.196, pp. 53-70.

i.

d44 d/I 6-5 TERA CORPORATION

Schnabel, P. B. and Seed, H. B.,1973. Accelerations in Rock for Earthquakes in the Western United States, BSSA V. 63, p. 501.

Seed, H. B., and Idriss, I. M.,1970. A Simplified Procedure - Soil Liquefaction Potential. Earthquake Engineering Research Center Report No. 70-9.

Seismic Engineering Program Reports,1974. U. S. Geol. Survey Circular 713.

Seismic Engineering Program Reports,1975. U. S. Geol. Survey Circular 717-A.

Seisriic Engineering Program Reports,1975. U. S. Geol. Survey Circular 717-B.

Seismic Engineering Program Reports,1976. U. S. Geol. Survey Circular 717-C.

Seismic Engineering Program Reports,1976. U. S. Geol. Survey Circular 717-D.

Seismic Engineering Program Reports,1976. U. S. Geol. Survey Circular 736-A.

Seismic Engineering Program Reports,1976. U. S. Geol. Survey Circular 736-B.

Seismic Engineering Program Reports,1977. U. S. Geol. Survey Circular 736-C.

Seismic Engineering Program Reports,1977. U. S. Geol. Survey Circular 736-D.

A Study of Holocene Disp acement History along the South-Sieh, K. E.,1977.

8 Central Reach at the San Andreas Fault, Ph.D. Thesis, Stanford Univ.

Slosson, J. E., and Barnhart, J. T.,1967. Late Pleistocene Deformation in the Limekiln Canyon Area, Santa Susano Mountains, Southern Calif. Acad.

Sciences Bull. 66, pp.129-134.

Stepp, J. C.,1974. " Analysis of Completeness of the Earthquake Sample in the Puget Sound Area and its Effect on Statistical Estimates of Ecrthquake Hazard." Proceeding of Conf. on Microzonation, Seattle.

Thatcher, W. and Hanks, T. C.,1973. Source Parameters of Southern California Earthquakes, J. Geophys. Res 78, pp. 8547-8576.

Toppozodo, T. R.,1975. Earthquake Magnitude as a Function of Intensity Data.

Bull. Seis. Soc. Amer., Vol. 65, No. 5, pp.1223-1238.

Toppozodo, T. R.,1978. Personal Communication.

Townley, S. D., and Allen, M. W.,1939. Descriptive Catalog of Earthquakes of the Pacific Coast of the United States, 1769-1928. Bull. Seis. Soc. Amer.,

Vol. 29, No. l.

Trifunac, M. D.,1976. " Preliminary Analysis of the Peaks of Strong Earthquake Ground Motion-Dependence of Peaks on Earthquake Magnitude, Epicentral Distance and Recording Site Conditions," Bull. Seis. Soc. Amer. _66(1) pp.

I89-220..

's 4 o, O! 3 6-6 TERA CORPORATION

U. S. Atomic Energy Commission,1973. A Study of Vertical and Horizonto' Earthquake Spectro. WASH-1255.

Vogliente, V.,

1973.

Forecasting the Risk inherent in Earthquake Resistant Design. Ph.D. Dissertation, Civil Eng. Dept., Stanford University.

Weber, F. H., Jr., et o!,1973. Geology md Mineral Resources Study of Southern Ventura County, Cclifomia: Prelimincry Report 14, Califomic Division of Mines and Geology,102 p.

Weber, G. E.. and Lajoie, K. R.,1977. Late Pleistocene and Holocene Tectonics of the Son Gregorio Foult Zone Between Moss Beach and Point Ano Nuevo, Son Mateo County, California, Abstract,73rd Annual Meeting, Cordilleron Section, Geological Society of America, Socramento,524.

'Vinterer, E. L., and Durham, D. L., 1962. Geology of Southeastern Venturo Basin, Los Angeles County, Califomia: U. S. Geol. Survey Prof. Paper 334-H, 89 p.

Wright, T. L., Parker, E. S., and Erickson, R. C.,1973. Stratigraphic Evidence for Timing and Nature of Late Cenozoic Deformation in Los Angeles Region, California, Abstract, Am. Assoc. Petrol. Geologists,5_7,813.

7 Yeates, R.

S.,

1973.

Newport-Inglewood Fault Zone, Los Angeles Basin, California, Amer. Assoc. Petrol. Geologists Bull 57, pp. ll7-135.

Yerkes, R. F., McCulloch, T. H., Schoellhamer, J. E., and Vedder, J. G.,1965.

Geology of the Los Angeles Basin, California-An introduction, U. S. Geol.

Survey Prof. Paper 420-A, Washington, D. C.,57 p.

j 4 k h 7 k 6-7 TERA CORPORATION