g n at:v,*'

[

NUCLEAR REGULATORY COMMISSION UNITED STATES

! '?.., ))" kh.E

}.[44%

REGION 11 o,

[

101 M A GIETT A ST, N.W., SUITE ~;100 N. s J

ATLANT A. G EORGI A 30303

'3 ')

2 JAN 2 31951

.\\

\\ N. %(c ' rq E

t Wu l Er3 I'v0wSiaIAL CCdP04ATION C'

~

O O ISSJ g }

k.~

230 413T 3 TWEET 3..

8=ruu O..

.ta ae4T E r.,

vi 23607

'"m 4"C LIO. s t&QLje 9_y0 L; Y,).

Q N

fc Gentlemen:

The enclosed Inf ormation Notice No. 81-02 is f orwarded for your information and guidance in the requirements f or safe transportation and carriage of radio-graphic devices. If there are any questions related to this notice, please contact this office.

Sincerely, c

W

._ 1 -3,~ q /

=

y James P. O'Reilly Director

Enclosures:

1.

IE Information Notice No. 81-02 w/its enclosures Tist of Recently issued IE Information Notices 81 02180cib

SSINS No.

6870 Accession No.

80S220287 UNITE.D STATES

$UCLEAR REGULATORY C091ISSION OYFICE OF INSTECTION AND EhTCRCEMENT WASHINGTON, D.C.

20555 Janua ry 23, 1981 lE Information Notice No. 81-02: TRANSPORTATION OF RADIOGRAPHY DEVICES

Background:

Recent inspections by NRC have identified frequent noncompliance with trans-portation regulations by radiography licensees.

As of December 3, 1979, the NRC inspection pregram has included inspection / enforcement of DOT regulations in 49 CFR 170-178 as direct NRC requirements (see 10 CFR 71.5).

The nature of radiography operations is somewhat unique in that radiography devices most f requently serve a dual function; that is, they serve as operational radiography cameras / source changers and as transportation packages.

Historically, this has caused some confusion on the part of radiography users, particularly with.espect to sorting out the transport regulatory requirements of 49 CFR/10 CFR 71 from the operational requirements of 10 CFR 34 and the specific license which has been issued to the radiography use..

Another source of confusion for the radiography operator is that he most frequently functions, with respect to the transportation regulations, in the dual role of both shipper and carrier.

This notice discusses some of the pertinent transportation requirements for radiography devices when used as transport " packages." The explanations should help to clarify the application of operational licensing requirements versus transport requirements applicable to shippers and carriers, thereby enhancing regulatory compliance with the requirements.

Discussions:

Source Design -- Radiography sources contained within a device are always encapsulated (Co-60 or Ir-192) and, therefore, meet the physical integrity requirements of "special form" as defined in 49 CFR 173.389(g) and 173.398(a).

Radiography transporters are reminded that these requirements call for each shipper of a special form source to maintain a file of supporting safety analysis or documentation containing the results of the testing performed on the source to demonstrate that it meets the special form requirements. This does not mean that each shipper has to actually perform the tests, only that

%ef "w!W#4m the tests. As a prac*.ical matter, (f;'