(O ' ' g C) D

  • N '"

/s

,f s

tb UNITED STATI'

~

/ 'b ATor.1r CNERGY CO' 1 MISSION I

br,

~<

w,... m c.m n...

".i S'

...Jiu J. P. O'Reilly, Chief, Reactor
.nspection and Enforce =ent Branch, CO VENDOR INSEECIION REERr (B&W 69/9) - BABCOCK & WILCCX, EAP"*ICN, OHIO The enclosed report of an inspection of the Babcock & Wilecx Co=pany.

(B&W) in Barberton, Chio en Dece=ber 16-18, 1969, is forwardec' for info =stion.

The inspection was made to review fabrication of steam generators for the Duke Pcver Cc=pany (Oconee plants) and the Florida Pcver Corporat'z t (Cr/stal River plant).

On the basis or cur observations and record exa inations, we believe the steam gener. ior units being =anufactured by E&W vill be satis-factor / for service. Ecvever, during the inspection our inspector identified four itens of nonconf smance with the applicable ASME Cedes which require corrective action. These ite=s relate to the qualification of velders to Navy rather than ASE require =ents and irregularities in the qualification and use of velding procedures.

We plan to e-micate with the respective licensees concerning the correction of these deficiencies and vill follev up en them as nee-essary. We also plan to continue periodic inspections of the Barberten facility.

G. W. Rein::.uth, Reactor Inspector (Program Standards)

Division of Cc=pliance

Enclosure:

IAW 69/9 ccv/ enclosure:

E. G. Case, DRS R. S. Boyd, DEL (2)

S. Levine, DEL (6)

D. J. Skovholt, DFL (;

L. Kornblith, Jr., CO R. W. Kirk =an, C0:I J. G. Davis, CO:II

3. H. Grier, CO:III D. I. Walker, CO:I7 R. W. Smith, C0:V

~

H. D. Thornburg, CO:I7I g Central File ef s

7 9 08 0 3 0 DN

[

q M.

q' \\